HomeMy WebLinkAboutOV160307001
100
oQOyP�I-EY gq�zo29 TOWN OF ORO VALLEY
DEVELOPMENT & INFRASTRUCTURE SERVICES DEPARTMENT
11000 N. LA CANADA DRIVE, ORO VALLEY, AZ. 85737
PHONE: (520) 229-4800 FAX: (520) 742-1022
www.orovallevaz.gov/dis �\ '�
•��UNDED A9�d!` J V � ( D ( S E)
1.2 GENERAL APPLICATION FORM Office Use Only
OV Case #: ==
....................... .
Application
Type
❑
Major General Plan Amendment
❑
Final Plat
AON
❑
Rezoning/PAD Amendment
❑
Pre -Application ��
❑
Planned Area Development
❑
Zoning Verification
❑
Conditional Use Permit
❑
Sign Criteria
❑
Zoning Code Amendment
❑
Sign - PAD Exemption
❑
Conceptual Site Plan
❑
Master Sign Program
❑
Conceptual Public Art
®
Communication Facility — Tier 1 and 2 Minor
❑
Conceptual Architecture
❑
Communication Facility — Major
❑
Final Site Plan
❑
Revised Development Plan
❑
Conceptual Landscape Plan
❑ Other
Subject Property Information:
Address: 55 E. Tangerine Rd.
Parcel/Tax Code: 219-53-0010
Subdivision / Commercial Center Name:
Book / Page or Sequence Number:
Lot Number(s)
Legal Description:
Section/Township/Range:
Area of Property:
Existing Land Use: R-1-144
Proposed
Land Use: Wireless Facility (existing)
Applicant Information:
Applicant *:
* If more than one, attach list
Name: Lisa Sennott Firm: Smartlink LLC on behalf of AT&T
Address: 8502 E. Via de Ventura, Ste 220 City: Scottsdale State: AZ Zip: 85258
Telephone: 602-739-5634 Fax: Email: Iisa.sennott(a)smartlinkllc.com
Property Owner(s) if different from Applicant *:
Name: nanny Madril Firm: TFP Ti ircnn FIPCtrir Pnwar)
Address: pn Rnx 711 City: Ti irspn State: A7 Zip:
Telephone: 520Ci61_g46n Fax:
Consultant: Site Acquisition
(Discipline)
Name: Lisa Sennott Firm: Smartlink LLC on behalf of AT&T
Address: 8502 E. Via de Ventura, Ste 220 City: Scottsdale State: A7 Zip: 85258
Telephone:602-73q-SF-4d Fax:
1
'amen n.■n, mrowen
Jr
Project Description/Narrative:
I hereby certify that I have read and examined this application and know the same to be true and correct. I am the owner
of the property or the Owner's authorized representative, and if not the owner, I have obtained the owner's permission to
perform stated work. All provisions of laws and ordinances governing this type of work will be complied with whether
specified herein or not. The approval of this application does not presume to give authority to violate or cancel the
provisions of any other federal, state or local law for which this project may be subject to.
Notice: It is the applicant/owner's responsibility to ensure all private rules and regulations (such as Covenants, Conditions
& Restrictions (CC&R's)) of the subdivision and/or commercial center are adhered to. Contact your Home Owners
Association or property management to determine applicable requirements.
It is also the applicant's responsibility to coordinate with all outside agencies to secure their acceptance or clearance.
Failure to do so may delay issuance of permits. See attached list of agencies.
1 ica Sannntt 11/8/16
Applicant's Signature Print Name Date
Important Note: All submittals received after 4:00 p.m. will be processed the next day
Submittals will be rejected if:
• Not folded using Pima County fold & collated;
• There are missing items on the checklist unless otherwise approved by Planning Division Manager or Town Engineer.
• Re -submittals cannot be accepted without a transmittal and a written narrative summary describing the purpose of
submittal.
....................... •�
jr 9101 6.0 AON
.�i
sii3"r;.ia�.
2
i�5�
at&t
Project Submittal Narrative
T614—TANG ERINE/COPPER SPRING RD
AT&T LTE Project
55 E. Tangerine Rd., Oro Valley, AZ 85737
(Existing Wireless Communications Facility, "WCF")
Submitted By:
Lisa Sennott
Smartlink LLC
8502 E. Via de Ventura, Suite 220, Scottsdale, Arizona 85258
(602) 739-5634 /lisa.sennott@smartlinkllc.com
AT&T 2C LTE Project- Antenna
Upgrade for Existing Wireless Communication Facility (WCF)
T614 —TANG ERIN E/COPPER SPRING RD
AT&T LTE Project
55 E. Tangerine Rd., Oro Valley, AZ 85737
APN 219-53-0010
Description of the Site / Purpose of Modification:
This application is for replacement of (2) existing antennas, Install (4) TMAs behind
antennas and remove (2) TMAs on an existing 65' Utility Pole.
The proposed modification will handle the additional demand for wireless data and
voice service for the surrounding area- particularly for residents, businesses, and
emergency personnel. Furthermore, the new antennas and equipment at this site will
incorporate the new E-911 call tracking requirement by the FCC.
Subject Parcel
Other than the Wireless Communications Facility (WCF), Land Use of Subject Parcel is
situated in the TEP Sub -Station
An aerial photo of the site is located below.
Source: Google Earth
The current array is comprised of 2 Panel Antennas, 2 Tower Mounted Amplifiers
(TMA's), 8 Lines of 1 %"" Coax, and 2 RET Cable mounted at a 64' RAD (Antenna
Centerline) on an existing 66' utility pole.
The Modification will comprise of replacing 2 Panel Antennas, install 4 TMAs, and 3 RRH
units for the LTE enhancement project.
The Final Configuration will not change the RAD (Antenna Centerline) at 64" nor
increase the antenna array.
Though there will some ancillary equipment replaced within the AT&T equipment
enclosure, there will not be a modification to size or dimension of the equipment area in
the TEP Sub -Station Compound.
Access to the facility, equipment shelter, and compound will continue to be limited to
authorized personnel only. The communication facility will continue to have no impact
to vehicular or pedestrian pattern; it does not and will not utilize connection to any
water system, refuse collection, or sewer system. The existing and proposed equipment
does not and will not emit any odor, dust, gas, noise, vibration, smoke, heat or glare.
Project Routing Form
Project Name / Number
Review Comments / Notice
Final Due Date
Project Manager
OV1603070 AT&T Cell
Approval Letter
11-28
Patty
Site
Routing
Received
Due Date
Met / Not Met
Due Date Details
To PP
11-23
11-28
12 days before Final Due Date
PP Redlines
1 day before Final Due Date
To App or AA
Final Due Date
Comments•
PROJECT TEAM I
CLIENT REPRESENTATIVE
COMPANY: SMARTLINK, LEG
ADDRESS: 605 WEST KNOX ROAD, SUITE 210
CITY, STATE, ZIP: TEMPE. AZ 85284
CONTACT: AHMED IQBAL
PHONE: (723) 742-6575
E-MAIL: ohmed.igbol®smartlinkllc.com
PROJECT OWNER
COMPANY: AT&T
ADDRESS: 1355 WEST UNIVERSITY DRIVE
CITY, STATE, ZIP: MESA, AZ 85201 -5419
CONTACT: SHAH KHAUD
PHONE: (480) 444-4689
E-MAIL: sh0h.kholid®ctt.com
PROF=SSIONAL OF RECORD
COMPANY: XD INBUS-RIES
ADDRESS: 3116 S. MILL AVENUE, SUITE 101
CITY, STATE, ZIP: TEMPE, AZ 95252
CONTACT: JOHN RODRIGUEZ
PHONE: (562) 833-4593
EMAIL: jrodriguez®xd-ind.com
PROPERTY OWNER
COMPANY: TUCSON ELECTRIC POWER
ADDRESS: 55 TANGERINE RD
CITY, STATE, ZIP: ORO VALLEY, AZ 85737
CONTACT: DANNY MADRIL
PHONE: (520) 661-9460
EMAIL: DModril®tep.com
TOWER OWNER
COMPANY: TUCSON ELECTRIC POWER
ADDRESS: 55 TANGERINE RD
CITY, STATE, ZIP: ORO VALLEY, AZ 85737
CONTACT: DANNY MADRIL
PHONE: (520) 661-9460
EMAIL: CMadril®tep.com
GENERALNOTES
DO NOT SCALE DRAWINGS
CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND
CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE
ARCHITECT/ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE
PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME.
THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. A
TECHNICIAN WILL VISIT THE SITE AS REQUIRED FOR ROUTINE MAINTENANCE.
THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT DISTURBANCE OR
EFFECT ON DRAINAGE; NO SANITARY SEWER SERVICE, POTABLE WATER, OR
TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SIGNAGE IS PROPOSED
SITE INFORMATION
LATITUDE:
32' 25' 31.155" N
LONGITUDE:
-119 58' 13.5474" W
LAT / LONG TYPE:
NAD 83
GROUND ELEVATION:
2805' AMSL
APN #:
219-53-0010
AREA OF CONSTRUCTION:
EXISTING
ZONING/JURISDICTION:
TOWN OF ORO VALLEY
CURRENT ZONING:
R1-144
EXISTING USE:
UNMANNED TELECOMMUNICATIONS FACILITY
COUNTY:
PIMA COUNTY
HANDICAP REQUIREMENTS:
FACILITY IS UNMANNED AND NOT FOR
HUMAN HABITATION. HANDICAPPED ACCESS
NOT REQUIRED.
CALL 811 0,(800)782-8048
• A WWW.ARIZONA811.COM
m ILI,
11mm
T614 AZL00614
TANGERINE/COPPER SPRING RD
55 E. TANGERINE RD.
ORO VALLEY, AZ 85737
2C PTN: 3901AO792L
FA: 10091127
USID: 24118
VICINITY MAP
p
INNOV
CORPC
CENT
COYOTE RIDGE
sc,
TANGERINE
>❑
HEIGHTS
/H�
O
N i'ta�dl;vanYe
F.�
s T a09`'0ne
Tz i''mie Rd
T
ERINE 2
Z Z
_z
,a
RRACE
Z A
2
`L
ae M
ORTH
O Ncol NO SCALE
- DRIVING DIRECTIONS - -
DIRECTIONS FROM AT&T OFFICE:
FROM AT&T PHOENIX OFFICE GO SOUTH TO THE LOOP 101, TAKE THE LOOP 101 WEST FOR ABOUT A MILE TO THE 51 (THE PIESTEWA FWY.). GO SOUTH ON THE 51
ALL THE WAY TO INTERSTATE 10 (1-10), TAKE THE 1-10 EAST TOWARD TUCSON, ABOUT 93 MI, EXIT OFF ONTO W. TANGERINE RD., TAKE TANGERINE RD. EAST FOR
ABOUT 11.4 MILES, THE SITE WILL BE ON THE LEFT.
CODE COMPLIANCE
BUILDING CODE: INTERNATIONAL BUILDING CODE 2012 (WITH CITY AMENDMENTS)
ELECTRICAL CODE: NATIONAL ELECTRICAL CODE 2011 (WITH CITY AMENDMENTS)
LIGHTNING PROTECTION CODE: NFPA 780 - 2000, LIGHTNING PROTECTION CODE
SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL
CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION
THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF
CONTRACT AWARD SHALL GOVERN THE DESIGN.
FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING
MATERIAL, METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE
REQUIREMENT SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT
AND A SPEC HC REQUIREMENT, THE SPECIFIC RECUIREMEN` S-ALL GOVERN.
RFDS DATA
DESIGN PACKAGE BASED ON RF DATA SHEET
REDS NAME: AZLOO609 NUMBER OF QUAD WCS FILTERS: 0
REVISION: 1 NUMBER OF RET LINES: I
DATE: 07-21-16
NUMBER OF SECTORS: 2
NUMBER OF ANTENNAS: 2
NUMBER OF TMA UNITS: 4
NUMBER OF RRH UNITS: 4
NUMBER OF FIBER/DC SQUIDS: 0
NUMBER OF DC SQUIDS: 0
NUMBER OF FIBER CABLES: 4
NUMBER OF DC CABLES: 4
NUMBER OF COAX CABLES: 8
APPROVALS
THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS & AUTHORIZE THE
SUBCONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN. ALL OCCUMENTS
ARE SUBJECT-0 REVIEW BY THE LOCAL BUILDING DEPARTMENT & MAY IMPOSE CHANGES OR
MODIFICATIONS.
APPROVED
By Rosen Kirilov at 1:07 pm, Oct 13, 2016
A/E MANAGER: DATE:
PROPERTY OWNER: DATE:
JURISDICTIONAL APPROVAL
PROJECT DESCRIPTION
THIS PROJECT WILL BE COMPRISED OF:
CHANGES ON THE BE ANTENNA ARRAY:
• REPLACE (1) ANTENNA PER SECTOR, (2) SECTORS, (2) TOTAL
• NEW (2) TMA PER SECTOR, (2) SECTORS, (4) TOTAL
• REMOVE (2) TMA (1) PER SECTOR, (2) SECTORS. (2) TOTAL
HAN IN THE XI IN AT T I. M NT ENCLOSURE AREA:
• NEW (1) RRH UNIT PER SECTOR, (2) SECTORS, (2) TOTAL
• NEW (2) TWIN QUADPLEXERS PER SECTOR, (2) SECTORS, (4) TOTAL
• NEW (2) COMBINERS FOR UMTS
NEW (1) DC12-48-60-RM RACK MOUNTED
AC/DC SCOFF_:
DC POWER PLAN REVIEW:
• EXISTING ARGUS +24VDC POWER PLANT WITH (5) 3.1KW RECTIFIERS AND -48 DC TO DC
CONVERTER WITH (4) 2KW CORDEX RECTIFIER NO CHANGES
NEW (2) 20A BREAKERS FOR LTE 2C RRH UNITS
BATTERY CHECK:
EXISTING (20) GNS MARATHON BATTERY STRINGS NO CHANGES
• ESTIMATED BATTERY RESERVE TIME, 8.67 HOURS
A/C PANEL REVIEW:
SEE PANEL SCHEDULE FOR REQUIRED SCOPE.
HVAC UNITS:
OUTDOOR EQUIPMENT - NO HVAC'S.
APPROV D BY: TC/PZJDRBIB�A
f
PZ PROACT MrAGER
DRAWING INDEX
SHEET N0:
SHEET TITLE
REV
T-I
TITLE SHEET
0
A-1
OVERALL SITE PLAN
0
A-2
ENLARGED SITE PLAN
0
A-3
EQUIPMENT & AN-ENNA PLANS
0
A-4
EXISTING & NEW - SOUTH ELEVATIONS
0
E-1
EXISTING & NEW ELECTRICAL AC PANEL
0
E-2
NEW ELECTRICAL EQUIPMENT PI AN
0
G-1
NEW GROUNDING EQUIPMENT & ANTENNA PLAN
0
CONTRACTOR TO REFERENCE PACKAGE "B" FOR SCHEMATICS, WIRING DIAGRAMS AND DETAILS.
The NEW eaftt
1355 W. UNIVFR;ITY DR.
MESA, AZ 85201
1 0 1
S m ga r i n k
605 W. KNOX ROAD, SUITE 210
TEMPE, AZ 58284
Q)
•L
3116 S. MILL AVE. SUITE 101
TEMPE, AZ 95252
PROJECT NO:
T614
DRAWN BY:
MG
CHECKED BY.
JF
0 10,12,2016 100R CONSTRUCTION M�
A 09/29/20t 6,, 90Y. CONSTR UCNON MG
REV DATE DES-RIP71CN BY
AJg
NOV 0 9 ?016 .A
IT IS A vOLA710N OF LAVI FOR ANY PERSON,
LNLEES TI+E" ARE ACTING UNDER TFE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER.
TO ALTER THIS DOCUMENT.
T614
TANGERINE/COPPER
SPRING RD
55 E. TANGERINE RD.
TUCSON, AZ 85737
SHEET TI-LE
TITLE SHEET
SHEET NUMBER
T e
a
• _ I (E) 'AT&T'
• - NON-EXCLUSIVE
- I TECH PARKING
�1
o I
zi
zl
al
z
EXISTING RAWLAND,
OVERALL SITE PLAN
0
EXISTING RAWLAND,
EXISTING PROPERTY LIN _ a _ _ _ - - _
'may„ P
EXISTING mr
ENLARGE SITE PLAN A-2
� EXISTING CMW WALL
r'.yn"l,1 ENCLOSURE
1
_J
•
EXISTNG
BUILDING, TYP.
T.E.P. SUBSTATION
'
(ZONED R1-144)
•
PARCEL # 219530010
EXISTING BUILDING,
TYP.
�r ; ri rr rir
i
A
�/
(E) 'AT&T12'-"
WIDE NON; -EXCLUSIVE
ACCESS EASEMENT
EXISTING DIRT
ACCESS ROAD
\�T
ew 1 fi
/
EXISTING ACCESS
DRIVEWAY
ING PROPERTY LINE
oev T-ww at&t
1355 W. UNIVERSITY DR.
MESA, AZ 85201
Q
1 Lu/ `§ /
EXISTING RAWLAND,
(TYP)
�— EX STING PAVED
/ ACCESS ROAD
/
E. TANGERINE RD.
0
EXISTING RAWLAND,
(TYP)
0 '0' 40• 80
0?
smsrUhk
605 W. KNOX ROAD, SUITE 210
TEMPE, AZ 58284
cn
Ln�
3116 S. MILL AVE. SUITE 101
TEMPE, AZ 95252
PROJECT NO: T614
DRAWN BY: MG
CHECKED BY: JF
0 10/12/2016 'D_ CONSTRUCRON MG
A 09/29/201E 90x CONSTRUCTION MG
REV I DATE I DESCRIPTION BY
IT IS A NOIA10N OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
T614
TANGERINE/COPPER
SPRING RD
55 E. TANGERINE RD.
TUCSON, AZ 85737
SHEET TITLE
OVERALL SITE PLAN
SHEET NUMBER
A-1 _j
DISCLAIMER NOTE:
XD INDUSTRIES HAS GENERATED A SITE PLAN WITHOUT USING A
TOPOGRAPHIC SURVEY. PROPERTY LINES, POWER/TELCO UTILITY POINT OF
CONNECTIONS/ROUTES AND EASEMENT SHOWN ON THIS PLANS ARE
ESTIMATED. XD INDUSTRIES HIGHLY RECOMMENDS GETTING A TOPOGRAPHIC
SURVEY FOR THE PROPERTY TO VERIFY THE MEASUREMENTS AND
ACCURACY.
EXISTING RAWLAND,
(TYR)
ENLARGED SITE PLAN
EXISTING WALL MOUNT
UTILITY PULL BOX, TYR.
EXISTING WALL MOUNT
METER, TYP.
EXISTING UTILITY
PULL BOX, TYP,
EXISTING 'AT&T'
CONCRETE STEP
I
I /I
I \ /
I /
I /
(E) 'AT&T'
1
NON—EXCLUSIVE
TECH PARKING I /
I /\
I / \
I /
I / \
I /
I / \
I / \
EXISTING DIRT ROAD TO /
'AT&T' EQUIPMENT AREA
EXISTING AT&T
/
/
i
I
I
I
I 4
I
/
/
/
/
/
EXISTING CHAIN LINK
ENCLOSURE (BY OTHERS)
EXISTING 'AT&T'
LIGHT POLE, TYR.
I
»
— — — — — — — EXISTING 'AT&T'
EQUIPMENT ENCLOSURE
NEW AT&T 3
EQUIPMENT PLAN A-3
EXISTING 10'-0" HIGH
CMW WALL ENCLOSURE
EXISTING 'AT&T' ANTENNAS
MOUNTED ON 67'-0*
POWER POLE
EXISTING POWER
LINES
T.E.P. SUBSTATION
EXISTING
SUBSTATION YARD
EXISTING 'AT&T'
LIGHT POLE, ttP.
Tt- NEw toaut
1355 W. UNIVERSITY DR.
MESA, AZ 85201
smardhk
605 W. KNOX ROAD, SUITE 210
TEMPE, AZ 58284
Lors-i C
3116 S. MILL AVE. SUITE 101
TEMPE, AZ 95252
PROJECT NO: T614
DRAWN BY: MG
CHECKED BY: JF
O 10/12/2016 'T. CONSTRUCTION My
A 09/29/2016 90S CONSTRUCTION MG
REV I DATE DESCRIPDCN BY
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSONAL ENGINEER,
TO ALTER THIS DOCUMENT.
T614
TANGERINE/COPPER
SPRING RD
55 E. TANGERINE RD.
TUCSON, AZ 85737
SHEET TITLE
ENLARGED SITE PLAN
SHEET NUMBER
-2
s
EXISTING WALL MOUNT EXISTING 'AT&T' ANTENNA ARRAY, AAJ
TELCO JUNCTION BOX, TYP. EXISTING 'AT&T' (1) ANTENNAS PERSECTOR,
TELCO CABINET (2) SECTORS, (2) TOTAL.
EXISTING WALL MOUNT -POSITION (1) TO BE REPLACEDUTILITY PULL BOX, TYP. , EXISTING 'AT&T'
AC PANEL
EXISTING WALL MOUNT EXISTING 'AT&T'
UTILITY PULL BOX, TYP. DDN W/EQUIPMENT
(2) EXISTING 'AT&T' TEXISTING 'AT&T' WALL �- ''-
UNITS PER SECTOMOUNT METERTYP. ,rr- i (2) SECTORS, (2) TOTl ( -POSITION (1) 1 TO BE REMOVED
EXISTING 'AT&T' WALL EXISTING 'AT&T' CHAIN 1 `
MOUNT UTILITY BOX, TYP. LINK ACCESS GATE 4
EXISTING WALL ,�
MOUNT UTILITY BOX, TYP. ��, EXISTING POWER
/ 'X EXISTING 'AT&T' LINE, TYP.
GRAVEL AREA
.EXISTING 'AT&T'.
CONCRETE STEPS ESTIMATED BATTERY
j RESERVE TIME, 8.67 U/r
EXISTING "ATV -.F HOURS ti� tiJ
CONCRETE STEP
V
EXISTING "AT&T'
ACCESS DOOR =_= o I
EXISTING 'AT&T' Z
nh* UMTS CABINET w
(1) EXISTING 'AT&T' WALL K- EXISTING ANTENNA PLAN
MOUNTED RRH PER SECTOR, S:f
(2) SECTORS. (2) TOTAL EXISTING 'AT&T' TE40 BATTERY Z
n
CABINET, WITHIN (20) GNB
(1) NEW 'AT&T' WALL MOUNTED ; MARATHON BATTERY STRINGS, Lx"
RRH PER SECTOR, — AND BATTERY RESERVE TIME, r
(2) SECTORS, (2) TOTAL j 8.67 HOURS s
NEW 'AT&T' WALL MOUNTED EXISTING 'AT&T' ARCUS TE41 2oP\p
COMBINERS FOR UMTS '" ,G POWER W/ (1) DC TO DC �%O
(TYP. OF 2) CONVERTER & (1) DC6 SURGE
/// SUPPRESSOR TO BE REPLACED
EXISTING 'ATV LTE CPS ✓ l '%
ANTENNA MOUNTED TO /
COLUMN WALL (2) NEW 'AT&T' 20A BREAKERS
TO BE INSTALLED NEW 'AT&T' ANTENNA ARRAY,
FOR LTE 2C RRH'S 1
EXISTING 'AT&T' (1) ANTENNA PER SECTOR,
LTE CABINET (2) SECTORS, (2) TOTAL,
(1) NEW 'AT&T' RACK MOUNTED -
DC12-48-60-RM SURGE POSITION (1) 1 NEW
(2) NEW 'AT&T' WALL MOUNTED TWIN QUADPLEXERS PER SUPPRESSOR / (2) NEW 'AT&T" TMA UNITS,
SECTOR, (2) SECTORS, (4) TOTAL EXISTING 'AT&T' PER SECTOR, (2) SECTORS,
CONCRETE PAD (4) TOTAL,
EXISTING 10'-0" -POSITION (1) 2 NEW
HIGH CMU WALL
EXISTING 'AT&T' CHAIN
LINK FENCE
1 V-5" T
EXISTING 'AT&T' ENCLOSURE
1
EXITING EQUIPMENT PLAN
EXISTING POWER
LINE, TYP.
U ti
N.
J
U �
"
N
V76
o
3 1 NEW ANTENNA PLAN
EXISTING 'AT&T'
CABLE METAL SHROUD
EXISTING POWER
LINE, TYP.
KK I� P P P - P
EXISTING 'AT&T' 67'-0"
HIGH POWER POLE
0 30' 6D' 12- I 1
EXISTING 'AT&T'
CABLE METAL SHROUD
EXISTING POWER
�1 JLINE. TYP�
P \P- P P
EXISTING 'AT&T' 67'-0"
HIGH POWER POLE
Tt- NEw toaut
1355 W. UNIVERSITY DR.
MESA, AZ 85201
a?
aartfonk
605 W. KNOX ROAD, SUITE 210
TEMPE, AZ 58284
Q)
� J �
3116 S. MILL AVE. SUITE 101
TEMPE, AZ 95262
PROJECT NO: T614
DRAWN BY: MG
CHECKED BY: JF
0 10/12/20161100x CONSTRUCTION MO
q 09/29/2016 90% CONSTRUCTION MO
REV I DATE I DESCRIPTION BY
IT I$ A NOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESS'ANAL ENGINEER,
TO ALTER THIS DOCUMENT.
T614
TANGERINE/COPPER
SPRING RD
55 E. TANGERINE RD.
TUCSON, AZ 85737
SHEET TITLE
EXISTING EQUIPMENT
& ANTENNA PLANS
SHEET NUMBER
A-3
!' B' 16' 32'
I
(2) EXISTING 'AT&T" TMA
UNITS PER SECTOR,
(2) SECTORS, (2) TOTAL,
-POSITION (1) 1 TO BE REMOVED
EXISTING 'AT&T' ANTENNA ARRAY,
(1) ANTENNAS PER SECTOR,
(2) SECTORS, (2) TOTAL.
-POSITION (1) TO BE REPLACED
EXISTING POWER
TYP.
-f
-�-1
LINES,
I _
,i
i I '
EXISTING 'AT&T' 67'-0"
I II
I I
HIGH POWER POLE
I
EXISTING 'AT&T' COAX RUN
4 X 1 1/4" + 4 X 7/8"
APPROX. t120'-0"
EXISTING 'AT&T' LTE CPS
ANTENNA MOUNTED TO
COLUMN WALL
EXISTING 'AT&T'
LTE CABINET
EXISTING 'AT&T' WALL
MOUNT METER, TYP.
EXISTING "AT&T'
CONCRETE STEP
EXISTING SOUTH ELEVATION
NEW 'AT&T' ANTENNA ARRAY,
(1) ANTENNA PER SECTOR,
(2) SECTORS, (2) TOTAL,
-POSITION (1) 1 NEW
t_(2)
f
NEW 'AT&V TMA UNITS,
I.,
PER SECTOR, (2) SECTORS,
(4) TOTAL,
EXISTING POWER
TYP.
-POSITION (1) 2 NEW
LINES.
I
i I ,
EXISTING 'AT&T' 67'-0"
I
I
I
HIGH POWER POLE
� I
EXISTING 'AT&T' COAX RUN
i I '
APPROX. 1:120'-0"
EXISTING 'AT&T' LTE CPS
ANTENNA MOUNTED
COLUMN WALL
I
(2) NEW 'AT&T' WALL MOUNTED
TWIN OUADPLEXERS PER
SECTOR, (2) SECTORS, (4) TOTAL f
EXISTING 'AT&T'
LTE CABINET
EXISTING 'AT&T' WALL
MOUNT METER, TYP. —\
EXISTING "AT&T' I
CONCRETE STEP
NEW SOUTH ELEVATION
I Z
Z
2 W
Q
J
z W
Z
Q
a nQ.
"J o
I
a
z Z
W W
O V_
EXISTING 10'-0"
O
w 0
Z
U
a
HIGH CMU WALL
(2) NEW 'AT&T' 20A
BREAKERS TO BE
INSTALLED
FOR LTE 2C RRH'S
(1) NEW 'AT&T' RACK
MOUNTED DC12-48-60-RM
SURGE SUPPRESSOR
EXISTING 'AT&T'
CHAIN LINK FENCE
EXISTING 'AT&T'
CHAIN UNK FENCE
(BY OTHERS)
T�- NEwtoaut
1355 W. UNIVERSITY DR.
MESA, AZ 85201
a?
amarfihk
605 W. KNOX ROAD, SUITE 210
TEMPE, AZ 58284
A J=
3116 S. MILL AVE. SUITE 101
TEMPE, AZ 95252
PROJECT NO: T614
DRAWN BY: MG
CHECKED BY: JF
p 10/12/2016 1001G CONSTRUCTION MO
A 09/29/2016 90S CONSTRUCTION MG
REV I TE OESCRIPOCN BY
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A UCENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
T614
TANGERINE/COPPER
SPRING RD
55 E. TANGERINE RD.
TUCSON, AZ 85737
SHEET TITLE
EXISTING & NEW
SOUTH ELEVATIONS
SHEET NUMBER
SH
/ \ — 4
AC POWER PANEL Na 1 (ad!ding)
1201240VOLTS, 1-PHASE- 3-WIRE, 200A
AC POWER PANEL No. 1 (Proposed)
I.M240 VOLTS. I -PHASE. 34VIRE. 200A
The NEW eo{naw
1355 W. t.NIVFRSITY DR.
MESA, AZ 85201
smaPLOIk
605 W. KNOX ROAD, SUITE 210
TEMPE, AZ 58284
V)
L
"
�
�
3116 S. MILL AVE. SUITE 101
TEMPE, Azsszsz
MAIN LUG ONLY RATING IA
2M SYSTEM
VOLTAGE ): 240
MAIN LUG ONLY RATING (A):
_'Zo
SYSTEM VOLTAGE (V ) : 240
DESCRBPTtON
EXTERNAL I RECEPTACLE
VA
180
ev
C
BKR
1511
POSN
LI L2 iPOSN
BKR
3812
;"c
nc
VA
1000
DESCRIPTION
RECTIFIER MODULE e8-OFF
DESCRIP1ON
VA
tmc
BKR
POSN
L1
L2
POSN
BKR
tint
VA
DESCRIPTION
t
1180 2
:.._-
EXTERNAL GFCI RECEPTACLE
180
c
1511
1
1180
-
30/2
15/1
rtc
1000
RECTIFIER
AIR CONDITIONER1550
RECTIMER*11
1550
3012
30✓2
.._.
-:__ 4
rtc
-
1000
_.._
RECTIFIER !t1
1550
1550
c
c
30x2
32550
I 5
_330
4
6
nc
nc
1000
780
511111C...
1550
S
7
2330 6
! 1?308
1511
1511.nc
nC
780
190
AIR CONDITIONER
INTERNALGFCIRECEPTACLE
RECTIFIER r ,�
1550
C
3012
7
1730
8
1511
no
180
INTERNALGFCIRECEPTACLE
9
�33: 10
2011
nc
780
AC i ZIAAMP
1550
c
9
2330
ip
ZOl1
nc
780
AC 1 21iAMP
RECT!'1ERs3
1550
1550
c
c
3W2
11
13
1?3J Ire
17M, 14
2011
20M
nc
ne
ISO
IN
GFCI120AMP
GFO 2 V. AMP
RECTIFIER *3
1550
C
3012
11
1730
12
20l1
rid,
180
GFp120AMP
1550
c
13
1730
14
20l1
nc
180
GFp 2 20 AMP
PROJECT N0, T614
RECRF1ERe4
1550
C
3Qt2
15
17
:330 i6
311a " 1 18
20N
20r1
nc
ne
780
1564
AC 2 0 A9.fP
Te41AC'GFM20AMR
RECTIFIER04
1550
---
1550
C
c
3012
15 -
2330
16
Z011
t1c
T80
AC 2 20 AMP
1550
i C
REC FERaS
Iwo
C
30R
19
1?30
30n
nc
180
UMTSGFG3.QMIIP
17
3114
78
20/1
nc
1584
Te41 AGGrq 20 AMP
DRAWN BY: MG
RECTIFIER 05
1550
c
30l2
19
1730
20
3012
no
180
LIMITS GFCI 30AMP
CHECKED B : F
1550
C
rnC
180
21
1713�: _
1550
a
21
1730
22
nc
180
' RECMFTER=6
RECTIFIERt7-OFa
1000
C
3012
--
3012
23
1DGD _4
EhIFTY
RECTIFIER *6
1000
c
M2
23_
1000
24
EhIPTY
25
---
27
10X5 28
I 1000 28
-
Eh1PTY
-
EMPTY
1000
1000
7000
c
--
no
25
1000
_6
EMPTY
1000
c
RECTIFIER 97 -OFF
1000
no
3012
27
t000
28
EMPTY
29
1ODD 30
EMPTl
; ne,
PHASE TOTALS (VA):
CURRENT PER PHASE (.AC
,
1*114; 1207W
137 119!Am rase cannot exceed main breaker ratingPHASE
1000
nc1
29
1000
30
EMPTY
TOTALS A):
14414
12070
PANEL 70TAL (VAC
26484 ! Legend: c - continuous.
nc a non -continuous
CURRENT PER PHASE (A).
137
119
Amperes/phdSe careul exceed rndin brndker rating
PAKeLCAPACtTY (kVA). 45.0 CONNECTED LOAD (WA). 25.5
PANEL LOADING (100% non-cont load) (kVAX 8 8
PANEL LOADING (129°6 continuous load)1kVAK 21.9
PAIL LOADING 110TAL7 ptVA}: 3A7
SPARE CAPAGITY 1kVAk 17.3
NOTES:
t. Enter maxrnum VA (not KVA) ratit".g in "VA" columns...
2 Erterehher a "e" or "ne' M--durnn next to "VA" cotmns to Mews Continuous crNor ccrinuc:a Lear* yank Britt
concurrent with another, higher. load.
3 Menge two, utnically aojaicert ceiis in "Deser"on" and "BKR" columns for d uav pole breakers
4. For two pore breakers dlvioe total VA by : and assign metal load to each phase rless specified cthi rmse by
squipme t hlanudaeturer
5 Manually enwappropriate breaker size In -8KR" columns sized as required for the deuce
a. Spreadshheet wnll indicate Current per Phase. Loading and Spare Capacity emies in *t=U if the capacity is exceeded.
7 Cutrartt per Phase entry rift been adjusted 10 meout er 12$'n crecreinuoLs raring Ahere appllcatle.
3 Replace the52 notes with notes appropriate to the panes for Inclusion on the drakings.
9. Replace 8:us entries aboclwdh details on specific panel.
10 'ra partei VAth other than +44 pesltlons, delete craw :'roan as required Be caralut to copy fohnulae at, reeded
t 1. For panels with other main breaker sizes replace "200" WU, the appropriate rain breaker Size and use asbelbre.
PANEL TOTAL (VAT:
?6484
end: c = continuous. nc = non -continuous
PANEL CAPACITY (kVA): 48.0 CONNECTED LOAD (kVA): 26.6
PANEL LOADING (100% non -cord. bad) (kVA): 8.8
PANEL LOADING (125% continuous load : 21.9
) (kVA)-.
PANEL LOADING (TOTAL) 1.30.7
SPARE CAPACITY (kVA): 17.3
NOTES:
1. SITE IS EOUIPPEO WITH A 24VDC ARGUS POWER PLANTOUIFITTED WITH (5) 115A 3.1KW CORDEX RECTIFIERS
2. ARGUS POWER PLANTIS EOUPED WITH A ARGUS +24VDC ,' 48VDC CONVERTER. WITH (4) 37A 2KW CORDEX RECTIFIERS.
3. ArrCOTED CIRCUITS ARE DEPICTED IN DOLD AND ARE MARKED WITH AN A$7CPJ8K".
4. ENSURE ALL UN -USED SPARE CIRCUIT BREAKERS ARE SWITCHED TO THE OFF POSITION
5. PROVIDE A NEW TYPE WRITTEN PANEL SCHEDULE ON INTERIOR OF PANEL DOOR.
OTHER:
1. Entermaximum VA (not KVA) rating in "VA" columns.
Z. Er ter either a "c" cr "nc" In column next to "V A" colum ns to Indicate Continuous or Nor -continuous. Leave blank if not
Noncurrent with erottter, higher. bad.
3. Merge two vertically ayacent cells In "Description" and "BKR" columns for dual pole breakers.
4. Fort" pole breakers divide total VA by 2 and assign equal toad to each phases unless specified otherwise by
equipment Manufacturer
5. Manually enter appropriate breaker size in -BKR' columns sized as requited forthe deuce.
S. Spreadsheet, mil indicate Current per Phase. Loading and Spare Capacity entries in RED If the capacity is exceeded.
7. Current per Phase entry has been ac(usted to account for 125% ofeontinuous rating where applicable.
8. Replace these rotes with notes appropriate to the panel for inclusion on the drawings.
9. Replace Blue entries above with details on specific panel.
10. For panel vnth other than 44 positions, delete or add limes as required. Be careful to copy formulae as needed.
11. For panels with othor m ain breaker sizes replace "200" with the appropriate main breaker size and use as before.
Oi+zizo,6, ,D0% CONSTRUCTON
M
A
C9/29/2016'
90x CONSTRUCTION
IA,
REV
DATE
DESCRIPTION
BY
IT IS A VIOLATION OF Aw FOR ANY PERSON,
UNLESS THE: ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
7
0 ALTER THIS DOCUMENT,
T61 4
TANGERINE/COPPER
SPRING R D
55 E. TANGERINE RD.
TUCSON, AZ 85737
SHEET TITLE
EXISTING & NEW
ELECTRICAL PANEL
SHEET NUMBER
e
EXISTING ELECTRICAL AC PANEL
2
NEW ELECTRICAL AC PANEL
1
EXISTING WALL MOUNT
TELCO JUNCTION BOX, TYP.
EXISTING WALL MOUNT
UTILITY PULL BOX, TYP.
EXISTING WALL MOUNT
UTILITY PULL BOX, TYP.
EXISTING 'AT&T' DC RUN FROM
EXISTING METER TO EXISTING
AC PANEL, 310'-0"
EXISTING 'AT&T' WALL
MOUNTED METER,
EXISTING POWER P.O.C.
EXISTING 'AT&T' WALL
MOUNT UTILffY BOX, TYP.
EXISTING WALL
MOUNT UTILITY BOX, TYP.
EXISTING 'AT&T'
CONCRETE STEPS
EXISTING "AT&T'
CONCRETE STEP
EXISTING "AT&T'
ACCESS DOOR
(1) EXISTING 'AT&V WALL
MOUNTED RRH PER SECTOR
(2) SECTORS. (2) TOTAL
(1) NEW 'AT0 WALL MOUNTE[
RRH PER SECTOR
(2) SECTORS, (2) TOTAL
NEW 'AT&T' WALL MOUNTEE
COMBINERS FOR UMT!
(TYP. OF 2;
EXISTING 'AT&T' LTE CPS
ANTENNA MOUNTED TO
COLUMN WALL
NEW 'AT&T' FIBER RUN FROM
EXISTING LTE CABINET TO NEW
RRH, t4'-O"
EXISTING 'AT&T'
LTE CABINET
(2) NEW 'AT&T' WALL MOUNTEI
TWIN QUADPLEXERS PEI
SECTOR, (2) SECTORS, (4) TOTAI
EXISTING 10'-0"
HIGH CMU WALL
NEW ELECTRICAL EQUIPMENT PLAN
4T&T'
31NET
AT&T
AT&T'
DUIPMENT
EXISTING 'AT&T' CHAIN
LINK ACCESS GATE
EXISTING 'AT&T'
GRAVEL AREA
EXISTING 'AT&T' DC RUN FROM
EXISTING AC PANEL TO EXISTING
POWER PLANT, t20'-0"
EXISTING 'AT&T' TELCO RUN FROM
EXISTING TELCO PANEL TO EXISTING
LTE CABINET, t20'-0"
EXISTING 'AT&T'
UMTS CABINET
EXISTING 'AT&T' COAX RUN
4 X 1 1/4" + 4 X 7/8"
APPROX. t120'-0"
EXISTING 'AT&T' TE40 BATTERY CABINET,
WITHIN (20) GNB MARATHON BATTERY
STRINGS, AND BATTERY RESERVE
TIME, 8.67 HOURS
EXISTING 'AT&T' ARGUS TE41
POWER W/ (1) DC TO DC
CONVERTER & (1) DC6 SURGE
SUPPRESSOR TO BE REPLACED
(2) NEW 'AT&T 20A BREAKERS
TO BE INSTALLED
FOR LTE 2C RRH'S
(1) NEW 'AT&T' RACK MOUNTED
DC12-48-60-RM SURGE
SUPPRESSOR
EXISTING 'AT&T'
CONCRETE PAD
EXISTING 'AT&T' CHAIN
LINK FENCE
D 1®• 12 I NOT USED
Tt- NEw IS aut
1355 W. UNIVERSITY DR.
MESA, AZ 85201
605 W. KNOX ROAD, SUITE 210
TEMPE, AZ 58284
Fn
(3)
�L
Lore-
3116 S. MILL AVE. SUITE 101
TEMPE, AZ 95252
PROJECT NO: T614
DRAWN BY: MG
CHECKED BY: JF
r-
R IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT. J
T614
TANGERINE/COPPER
SPRING RD
55 E. TANGERINE RD.
TUCSON, AZ 85737
SHEET TITLE
NEW ELECTRICAL
EQUIPMENT AC PLAN
SHEET NUMBER
E-2
1
R IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT. J
T614
TANGERINE/COPPER
SPRING RD
55 E. TANGERINE RD.
TUCSON, AZ 85737
SHEET TITLE
NEW ELECTRICAL
EQUIPMENT AC PLAN
SHEET NUMBER
E-2
1
EXISTING WALL MOUNT
TELCO JUNCTION BOX, TYP.
EXISTING WALL MOUNT
UTILITY PULL BOX, TYP.
EXISTING WALL MOUNT
UTILITY PULL BOX, TYP.
EXISTING 'AT&T' WALL
MOUNT METER, TYP,
EXISTING 'AT&T' WALL
MOUNT UTILITY BOX, TYP.
EXISTING WALL
MOUNT UTILITY BOX, TYP.
EXISTING 'AT&T'
CONCRETE STEPS
EXISTING "AT&V
CONCRETE STEP
EXISTING 'AT&T'
ACCESS DOOR
(1) EXISTING 'AT&T' WALL
MOUNTED RRH PER SECTOR,
(2) SECTORS. (2) TOTAL
(1) NEW 'AT&T' WALL MOUNTED
RRH PER SECTOR,
(2) SECTORS, (2) TOTAL
NEW 'AT&T' WALL MOUNTED
COMBINERS FOR UMTS
(TYP. OF 2)
EXISTING 'AT&T' LTE CPS
ANTENNA MOUNTED TO
COLUMN WALL
(N) J2 AWG BTC COPPER
MINIMUM (TYP)
EXISTING 'AT&T'
LTE CABINET
(N) COMPRESSION
CONNECTION, (TYP)
(2) NEW 'AT&T' WALL MOUNTED
TWIN QUADPLEXERS PER
SECTOR, (2) SECTORS, (4) TOTAL
EXISTING 10'-0"
HIGH CMU WALL
NOTE:
CCNTRACTOR TO FIELD VERIFY 'GROUND BAR' EXACT LOCATION.
EXISTING 'AT&T'
TELCO CABINET
EXISTING 'AT&T'
AC PANEL
EXISTING 'ATV
DDTY W/EOU PMENT
4 p'
I EXISTING 'AT&T' CHAIN
�I I LINK ACCESS GATE
GROUNDING LEGEND
GROUNDING LINE TYPE:
GROUNDING —
GROUNDING SYMBOLS:
5/8" X 10'-0" ,CU. CND ROD IN
TEST WELL 30" MIN. BELOW GRADE.
e CHEMICAL GROUND ROD
(%IT GROUND ROD)
CADWELD CONNECTION
G — G
LIECHANtCAL CONNECTION
HALO GROUND CONNECTION
X--x GROUND BAR
NEW GROUNDING EQUIPMENT PLANGROUNDING EQUIPMENT PLAN
EXISTING 'AT&T'
GRAVEL AREA
EXISTING 'AT&T'
UMTS CABINET
EXISTING 'AT&T' TE40 BATTERY
CABINET, WITHIN (20) GNB
MARATHON BATTERY STRINGS,
AND BATTERY RESERVE TIME,
8.67 HOURS
EXISTING 'AT&T' ARGUS TE41
POWER W/ (1) DC TO DC
CONVERTER & (1) DC6 SURGE
SUPPRESSOR TO BE REPLACED
(2) NEW 'AT&T' 20A BREAKERS
TO BE INSTALLED
FOR LTE 2C RRH'S
:1) NEW 'AT&T' RACK MOUNTED
)C12-48-60—RM SURGE
SUPPRESSOR
EXISTING 'AT&T'
CONCRETE PAD
EXISTING 'AT&T' CHAIN
LINK FENCE
NEW 'AT&T' ANTENNA ARRAY, 1
(1) ANTENNA PER SECTOR, 9
(2) SECTORS, (2) TOTAL,
—POSITION (1) 1 NEW
NEW COMPRESSION
CONNECTION, (TYP)
EXISTING POWER
LINE, TYP.
9
9
GROUNDING LEGEND
GROUNDING LINE TYPE:
GROUNDING - G - G
GROUNDING SYMBOLS:
5/8' X 10'-0" ,CU. CND ROD IN
TEST WELL 30" MIN. BELOW GRADE
e CHEMICAL GROUND ROD
(XIT GROUND POD)
CADWELD CONNECOON
• MECHANICAL CONNECTION
HALO GROUND CONNECTION
M--iC GROUND BAR
) 1• 2' .• 12 I NEW GROUNDING ANTENNA PLAN
NOTE:
CONTRACTOR TO FIELD VERIFY 'GROUND BAR' EXACT LOCATION.
EXISTING 'AT&T'
CABLE METAL SHROUD
NEW J2 AWG BTC COPPER
MINIMUM, (TYP)
/ EXISTING GROUND
BARS (TYP.)
EXISTNG POWER
LINE, TYP.lN
1 e n n + +
Y
\—(2)
EXISTING 'AT&T' 67'-0'
HIGH POWER POLE
NEW 'AT&T' TMA UNITS,
PER SECTOR, (2) SECTORS,
(4) TOTAL,
—POSITION (1) 2 NEW
Th-NEW00aut
1355 W. UNIVERSITY DR.
MESA, AZ 85201
0
smardohk
605 W. KNOX ROAD, SUITE 210
TEMPE, AZ 58284
"L
�VAVI-j
� c:
3116 S. MILL AVE. SUITE 101
TEMPE, AZ 95252
PROJECT NO: T614
DRAWN BY: MG
CHECKED BY: JF
ow
m_—m
IT IS A VIOLATION OF UW FOR ANY PERSON,
VNIOF RECA L ICE PR�Ey ARE ACTIOFESSONAL ENCINIEERTION
TO ALTER THIS DOCUMENT.
T614
TANGERINE/COPPER
SPRING RD
55 E. TANGERINE RD.
TUCSON, AZ 85737
SHEET TITLE
NEW GROUNDING
ANTENNA & EQUIPMENT
PLANS
SHEET NUMBER
G-1
OJp�,1.EY gR/20 i
FOUNDED 19 s1J(
1C�
Town of Oro Valley
Community Development and Public Works
November 23, 2016
Lisa Sennott
Smarklink LLC for AT&T
8502 E. Via de Ventura #220
Scottsdale, AZ 85258
Lisa.sennott@smartlinklIc.com
Re: Modification to a wireless communication facility located at 55 E. Tangerine Road, OV1603070.
Dear Lisa,
Thank you for submitting an application for a Tier 1 Wireless Communication Facility for At&T, replacing
two existing antennas and adding four TMA's at the above -referenced location.
The proposed facility modifications qualify for administrative approval under the recently adopted
Federal Communications Commission rulemaking regarding wireless communication facility
improvements.
In addition to the Federal standards, the proposed modifications meet the Town's Tier 1 standards due
to the proposed replacement antennas installed on an existing pole with no increase in height and
width to the pole or the from the size of the original antenna array.
The application has been reviewed and approved administratively by the Town.
Engineering
Engineering does not have any comments regarding the proposed project.
If the scope of work is modified during the design and/or permitting process, please note that a
Type 3 Grading Permit is required for grading related activities (e.g. trenching, grading, etc.)
associated with the installation of ground mounted equipment and equipment enclosures.
The next step is to submit building plans for review and approval.
Thank you again for your submittal and if you have any questions, please contact me at (520) 229-
4819.
Sincerely,
A�
Patty Hayes
Senior Planning Technician
Town of Oro Valley
520.229.4819, PhayesCa.orovalleyaz.gov
Oro Valley, it's in our nature.
11000 N. La Canada Drive, Oro Valley, Arizona 85737
www.orovalleyaz.gov I phone: (520) 229-4800 1 fax: (520) 742-1022