Loading...
HomeMy WebLinkAboutOV1701538Tier II Minor Wireless Communication Facility �fr Conceptual Design Review Board Staff Report PROJECT: Verizon cell tower in Innovation Park CASE NUMBER: OV1701538 It MEETING DATE: August 8, 2017 cqj AGENDA ITEM: 1 STAFF CONTACT: Milini Simms, Planner msimms(aD,orovalleyaz.gov (520) 229-4836 Applicant: Christine Tucker, Insite Inc. Request: Cell tower on replacement light pole in right-of-way Location: Near the southwest comer of Innovation Park Drive and Vistoso Village Drive Recommendation: Approve with condition (see Attachment 1) SUMMARY: The purpose of this request is to consider the design of a proposed cell tower on a replacement light pole with an accompanying ground -mounted equipment cabinet. The proposed cell tower is located in a Town right-of-way, near the southwest corner of Innovation Park Drive and Vistoso Village Drive (see Attachment 2). The proposed communication facility includes: • Replacing an existing 35.6 foot light pole with no height increase • Installing a canister or shroud around 2 antennas • Painting the canister to match replacement light pole • Low profile ground -mounted equipment cabinet (30" in height) • Natural screening of ground -mounted equipment cabinet This application (Attachment 3) requires approval by the Conceptual Design Review Board. The primary focus of the review is to ensure that the proposed cell tower design is compatible with the surrounding area. The request is consistent with the Zoning Code standards pertaining to communication facilities. Staff recommends approval, subject to the condition that the applicant obtain approval of a license agreement by Town Council. DISCUSSIONIANALYSIS: The proposed location of the cell tower is on a replacement light pole near the southwest corner of Innovation Park Drive and Vistoso Village Drive. Innovation Park consists of employment uses with no nearby residential uses in close proximity to the proposed cell tower location. The nearest residential OV1701538 Verizon Cell Tower in Innovation Park Conceptual Design Review Board Staff Report Page 2 of 4 area to the north is approximately one-half mile and the nearest residential area to the west is over one mile away, from the proposed cell tower. This analysis focuses on the proposed cell tower design and its compatibility with the surrounding area. Zoning Conformance The proposed cell tower meets the Tier II Minor Communication Facility requirements of the Zoning Code. A Tier 11 Minor Communication Facility is a discernible cell tower which 1) meets the dimensional requirements of the Zoning Code and 2) uses stealth applications to the greatest extent feasible. Dimensional Requirements The table below shows how the proposed cell tower meets the dimensional requirements for a Tier II Minor Communication Facility. Zoning Provision Maximum Allowed Proposed Tower height 46.2' 35.6' Maximum increase to pole diameter 13.4" 8.61' Stealth Design Stealth design is the camouflaging of a cell tower through the use of design, colors, materials, height and width. The applicant has demonstrated that the proposed cell tower uses stealth methods to the greatest extent feasible. These stealth methods include using slimmer antenna arrays, adding a painted canister to match the light pole, and maintaining the existing light pole height. A photo simulation of the existing and proposed light pole with the cell tower is provided as Attachment 4. Additionally, the accompanying ground -mounted equipment cabinet will be screened by existing vegetation and additional native plants provided by the applicant. Compatibility The proposed cell tower is compatible with the surrounding area based on the following: • The height of the replacement pole is the same as the existing pole height • The location is in the middle of an employment campus with no nearby residents • The use of stealth methods maintains the appearance as a light pole and adequately screens the ground -mounted equipment cabinet DesiQn Principle and Design Standard Conformance The following Design Principle and Design Standard are applicable to the request, shown in italics followed by staff comment. Wireless communication facilities shall be located in areas and designed in a manner which reduces the visual impact on the proposed project and surrounding area. Wireless communication antenna shall utilize the verticality provided by buildings and shall be incorporated into building design when applicable and appropriate. Visual impact of antenna and towers shall be reduced through the use of concealment methods including alternative designs and co -location on vertical elements of the development such as power poles, light poles and flag poles. The request is to co -locate on a replacement light pole in the right-of-way, consistent with the Design Principle and Design Standard. OV1701538 Verizon Cell Tower in Innovation Park Conceptual Design Review Board Staff Report Page 3 of 4 As information, the use of the right-of-way for this purpose requires approval of a license agreement by Town Council. A condition is included requiring the applicant to obtain approval of the required license agreement by Town Council. General Plan Conformance The proposed cell tower has been reviewed for conformance with the General Plan. A notable policy related to this request is provided below: Policy 11.3.2. The Town shall continue to require all new development and improvements to existing development, both public and private, to maintain and/or enhance the character and quality of views from and along scenic corridors and public parks... The proposed cell tower will have a minimal impact on the existing views because it will be installed on a replacement light pole and is surrounded by employment uses. PUBLIC PARTICIPATION: Summary of Public Notice Notice to the public was provided consistent with Town -adopted procedures, which include the following: • Properties within 600' feet • Posting at Town Hall • All registered HOAs No comments have been received on this request. As there are no residential properties within 600 feet of the request, a neighborhood meeting was not required by the Zoning Code. CONCLUSIONIRECOMMENDATION: Based on the following findings: • The request meets the Tier II Minor Communication Facility requirements. • The proposed design is compatible with the surrounding area. • The request is in conformance with the General Plan. Staff recommends the Conceptual Design Review Board take the following action: Approve the requested Tier I) Minor Communication Facility subject to the condition in Attachment 1. SUGGESTED MOTIONS: I MOVE to approve the request subject to the condition in Attachment 1, finding It is compatible with the surrounding area and meets the applicable zoning provisions and the General Plan. 141:1 I MOVE to recommend denial of the request, based on OV1701538 Verizon Celt Tower in Innovation Park Conceptual Design Review Board Staff Report ATTACHMENTS: 1. Condition of Approval 2. Location Map 3. Application 4. Photo Simulation Bayer Vella, AICP Planning Ma Page 4 of 4 Condition of Approval Obtain a Town Council approved lease agreement to locate facilities in a Town owned right- of-way, prior to receiving right -of way and building permits. OQo�PiIEY. A��O' Condition of Approval Verizon Tier II Communications Facility (OV1701538) Attachment 1 FnNNDED ��n ---- ,,� A a{ ., Ar a• t -� 14 4 Venil;pnq Medical ' 4 ti Systeffii� 1 y ; OQ,0 �PI.EV02.9 Location Map Verizon Tier II Communications Facility (OV1701538) UIVDED A Attachment 2 a TUC—VENTANA—SC — Coverage Map Before New Small Cell Site 1 W Legend x LTE: RSRP - Coverage (0) RSRP Level IDLI ItlBm) >=-65 RSRP Level IDq (dBm) >=.70 '. RSRP Level (Dq (dBml >=-75 RSRP Level (Dq (d0m1 > = 40 RSRP level IDLI (dBm1 > = 85 RSRP Level IDLI ItlBml > =-90 RSRP Level IDLI 1d0m) > =-95 RSRP Level IDq idBml > =-100 RSRP LeveIIDLI(d:.Q >_ 105 RSRP Level (DL) Itlml >=-110 RSRP Level (Dq ItlBml >=-115 RSRP Level IDq Id&m) > • •120 TUC—VENTANA—SC — Coverage Map After New Small Cell Site 0 t,x. xsnr - coer.oe um ■ ASAC L"11 IOU job.) , -4$ ■ RSai le.e+tOL, IGO.) ..ao asavt"IIN IPP•rj ••.7S ASAV lerN lot) IOBa , • W ■ ASAP LCW l➢U I • d5 ■ I=leW toU 14B.J •-.90 ■ ASADtewfoU I5BW ■ ASRD teeet M idB.B • •.too ■ ASAP Lerel ft 06.6 , •16S ■ NSAY teW IOU (dW -- Lto ■ RSAi loci (oU IaB" . -.L I ■ RSUP lert+loU 10P.1 , •-L2P APPROVE Y: T /PZ/DRBJBOA A RE PROJECT MANAGER verI onwireless Project Narrative 7/11/17 Verizon Wireless is seeking the Town of Oro Valley's review and approval of a wireless communication small cell to be co -located on an existing street light pole (replaced with a more structurally sound pole), located within the public R.O.W. at the SWC of E Innovation Park Dr and N. Vistoso Village Dr. Verizon has areas within its network where they do not currently have adequate capacity for data to meet their customers' needs. The area at Innovation Park Dr. is one such area. The proposed small cell site will provide data capacity for Verizon customers who need to use their mobile devices in the immediate area. We initially contacted, on 7/3/2014, Greg Thompson, the engineer at Ventana Medical Park, and he was interested in working with Verizon. Unfortunately after months of discussions and lease review, site visit, drawings, etc., Greg's Legal Department decided not to pursue the proposal. The Town's light pole was the only other solution in the area. We tried to locate on existing verticality, so as not to introduce another monopole. Ventana Medical Park opposed the first light pole location, so staff asked us to relocate to a different pole. This proposed wireless site will consist of two antennas that will be attached to a replacement light pole. The height of the new pole will be the same as the existing height at 35.6' AGL; there will be no increase in height. The existing pole is 8.4" in diameter, and the replacement pole will be slightly larger having an 8.625" diameter. The antennas will be installed on the light pole just above the arm. The antennas will be fully enclosed within a screen, painted to match the existing color of the pole. A ground mounted equipment cabinet will be installed near the base of the pole, approximately 6' away. The cabinet will be painted to match the rock within the R.O.W., and screened from view using existing and proposed vegetation located within the R.O.W. The installation of this site will not substantially add to the visual mass of the pole. The installation is compatible with the structure and surrounding area, as this area is a commercial zone. I have included Verizon's Communication Plan with this submittal. It consists of existing sites, as well as proposed sites, within the area. Verizon currently has 8 existing cell sites, 1 proposed cell site to be located on a rooftop at Ironwood High School, and 2 proposed small cells within the Oro Valley/North Tucson area. The sites are depicted on the map provided, as well as geographic coordinates for each of them. Also included is a coverage map of the sites. In addition to this proposed small cell, the other location Verizon has targeted is within the Oro Valley Marketplace. This location also needs additional capacity for data use. They are pursuing a roof top installation on Walmart. Other than that, there are no further sites needed based on current engineering data. Many factors, such as population growth in the area, could impact this in the future, possibly resulting in additional solutions. verizon%' 6/ 18/2017 To: Matt Dean Transmitted via email to: matt.dean(d)walmart.com RE: Verizon Small Cell: Outdoor Site Located at: West corner of E Innovation Park Dr. and N Vistoso Village Dr, Oro Valley, AZ 85755 To Whom It May Concern, We write to inform you that Verizon has performed a radio frequency (RF) compliance evaluation for the above -noted site and based on the result of the evaluation, this site is compliant with FCC Guidelines. The FCC has established safety guidelines relating to potential RF exposure from cell sites. The FCC developed the standards, known as Maximum Permissible Exposure (MPE) limits, in consultation with numerous other federal agencies, including the Environmental Protection Agency, the Food and Drug Administration, and the Occupational Safety and Health Administration. The FCC provides information about the safety of radio frequency (RF) emissions from cell towers on its website at: https://www.fcc.gov/enizineerin2-technolog/electromagnetic-compatibility-division/radio- frequency-safety/fag/rf-safety To ensure general public safety, it is important that you contact Verizon personnel at least 24 hours in advance should general maintenance need to be performed in areas where antennas are present. This is required to comply with FCC guidelines and ensure the environment is safe for general maintenance workers who may not have RF Safety & Awareness training. With notification, Verizon is able to evaluate appropriate actions needed relating to the antennas and proximity of the work location. Please refer to FCC Office of Engineering and Technology Bulletin 65 and the attached RF Brochure if you would like further information on RF exposure guidelines, RF safety, and property owner responsibilities. Policy -related questions should be directed to VZWRFCompliance(&verizonwireless.com. If you have any additional questions or concerns, please contact your local Verizon resource below: Contact Name IContact Email I Contact Phone Adam Chandler I Adam.Chandler VerizonWireless.com 1 480-752-7244 In the event that emergency maintenance must be performed on the facility and the above -noted contact is not available, please call the Verizon Network Operations Center at 800-264-6620 for assistance. Sincerely, Kadie Gavan Manager-RF System Design Verizon APPRT -D '-Y. BOA D� - Property Owner Responsibilities (M.E.N.U) RF exposure safety and the protection of every licensee's infrastructure are very important. Property owners and licensees have a shared responsibility in innainntaining a safe and secure RF environment. Property owners can help in this significant endeavor by-. => Maintaining all necessary wireless licensee contact information. => Enforcing restricted access (help maintain a Controlled Emiromnent). Ensuring all buuildinahnnaintenance personnel are aware that the potential for exposure exists, and follow all appropriate entry and safety procedures. => NotiLring all licensees when any non -carrier requests access to any area with antennas at least 24 hours in advance. => Understanding that compliance with the FCC and OSHA can be achieved with RF Exposure levels above the applicable linut if the proper si_nase, physical bmrier, and access restrictions are implemented. Conunitnnent to compliance and willingness to cooperate are essential. For General RF Safety & Awareness Questions Verizon Wireless E-mail: VZWRFCompliance Ct vzw.com E-mail Subject: "ATTN: RF Compliance' In The Event That Emergency Maintenance Is Reavired 24-Hour Network Operations Center: 1-800-264-6620 RF Safety & Awareness Training Contacts Amirit Technologies (%vww.amirit.com) C-Squared Systems (vnvw.csouaredsystems.comt Dtech Communications (%vvAv.dtechcom.com) EBI Consulting (www.ebiconsulting.com) Global RF Solutions (ww%v.grfs.net) Hammett & Edison, Inc. (www.h-e.com) Lawrence Behr Associates, Inc. (www.lbaizroan.com) LCC (wvrw.lcc.com) Millennium Engineering (www.mil lenni umengineering. nett Pinnacle Telecom Group (%vww.pinnacletelecomgroup.com) Richard A. Tell Associates (wvAv.radhaz.com) RSI (vnvw.rfcomoly.coml SiteSafe (www.sitesafe.com) Telnet (w Av.telnet-inc.com) Trott Communications Group (wv W.trottgroup.com) Waterford Consultants (www.,6vaterfordconsultants.co m) Radio Frequen(y (RF) Emissions Federal Compliance Requirements Compliance Materials The Federal Cvmrmmications Commission (FCC) has established safety guidelines relating to RF exposure from cell sites. The FCC developed those standards, ]mown as hLixiffirm Permissible Exposure (WE) limits, in consultation with numerous other federal agencies, including the Environmental Protection Agency, the Food and Drug Admin- istration, and the Occupational Safety and Health Administra- tion_ The standards were developed by expert scientists and engineers after extensive reviews of the scientific literature related to RF biological effects_ The FCC explains that its standards incorporate prudent margins of safety. The following represents an overview of the most applicable information: Classifications for Exposure Limits Occupational Persons are "exposed as a consequence of their employment" and are fully snare of the poten- tial for exposure and can exercise control over their expostre"- General Population Any persons that `ynay not be madeful6, maare of the potential for exposure or cannot exercise control over their exposure' - Those in this category do not have RF Safety & Awareness Training. Ensuring Compliance with FCC Guidelines Areas or portions of any transmitter site may be susceptible to high power densities that could cause personnel exposures in excess of the FCC guidelines. Wireless Licensees are required by law to implement the following: • Restrict access to areas with transmitting antennas. • Post notification signage on every access point to increase awareness of the potential for exposure BEFORE one enters an arcs with antennas. • Place additional notification signage and visual indicators in an area with antennas (beyond an access point) were RF exposure levels may start to exceed the FCC's limits. Notification Signage 8 waT ' (Notice) RF Guidelines - Informs viewer of the basic safety - - guidelines for working in an RF E ; Environment. •'IX, Ki 151 Information -Provides relevant Thl. b • Y*ft- " •" contact info®ation for any questions or requests. (Blue) Notice - Informs viewer that beyond the 00 sign, RF exposure levels may exceed the General Population MPE limit but will remain _ below the Occupational WE limit A--- (fellow) Caution - Infomu viewer that beyond the sign, RF exposure levels may exceed the General Population and Occupational MPE _ limit. (Red) warning - Informs viewer that beyond the sign, RF exposure levels may substantially exceed the General Population and Occupational MPE limit. Phvsical Barriers In addition to locked doors or ladders, wireless licensees may also be required to place physical barriers as a means of visually demarcating an area where RF levels are ex- pected to exceed the FCC's limits_ Examples of Physical Barrier Materials: plastic chains, buckets, stanchions, plastic cones, fiberglass fences, and poles mounted in cinderblocks_ Antenna Safety Antenna► Types ice_ Antenna that radiates energy in one direction. RF energy has a narrow beam a� Walk behind or under this antenna. Panel - Antenna that radiates �^----�01;" energy in one direction RF�r�—'- p energy beam can range from narrow to very wide. Walk =111 behind this antenna. Stay outm of the general direction that the antenna is pointing. ANUP - Antenna that radiates energy .elh, in ell A;-",;—. 7\rarniain ae much distance as possible from y this antenna. 'Microwave - Antenna that radi- ates energy in one direction- RF ' energy has a narrow beam Walk } under or behind this antenna. " na -%A'isen In An Environment with Antennas: Maintain at least a 3-foot clearance from all antennas. A 10-foot separation distance is preferred Never touch an antenna. Assume all are active. => Read and obey ALL signs on an access point => Read and obey ALL signs in the environment with antemias- => Never walk past an physical barrier without first confirming transmitter inactivity. Never walk in front of or stand in front of an antenna whenever possible. Keep walking. => Contact all wireless licensees at least 24 hours in advance of scheduled maintenance. IC LAMBERT 3HANN6N-RD SC TUCw-OPEN ow TUC_VENTANA_SC WEST VISTOSO TU C_LA-CANADA 1 % � H % 46=4 TUC LA-CANADA-LAI TUC EL-CONQUISTAD6R ft=,P TUC CIRCLE-K Verizon Wireless Proprietary and Confidential 1 I TI I VF=RITAAIA Rim M 7a 1 9 201 UILf7Z'Mwneless VerfZOnwireless TUC - VENTANA-SC SWC E. Innovation Park Dr & Latitude: 320 26'24.4"N N. Vistoso Village Dr. Longitude: 1100 56' 35.80"W Oro Valley, AZ 85755 US JUN 1 9 2017 e f 0r- g4 x ®FORGE, ALL RIC,' 1 S RESERVE W:\Cabinets\Small Alum Cabinets\SW-5091 \ pj�-L ' ' .ANAGcR F.- 82.72 -- -- -- 32.72 0.00 0 - - - 79.625 NMI NAME: SW-5091 Complete Assy DWG: S057142 AGT 04/21 /2015 Volume: 47.0 Cubic feet �20.13� Ivf J UN 1 9 2017 Sheet 1 of 3 `W:\Cabinets\Small Alum Cabinets\SW-5091 \ n lie NAME: SW-5091 Complete Assy DWG: S057142 AGT 04/21 /2015 Sheet 2 of 3' 'W: Cabinets\Small Alum Cabinets\SW-5091 \ NAME: SW-5091 Complete Assy Cutouts in floor DWG: S057142 A = 4.0� � X 4.0� � AGT 04/21 /2015 B = 6.0" X 8.011 32.50 I Sheet 3 of 3I CLIENT: APPROOD Y TC/PZ/DRB/BOA �DA PZ PR JECT MANI AGER venzonl/ TUC VENTANA SC SWC E. INNOVATION PARK DR. & VICINITY MAP 92n P 9 Zo �o s� Of os 5 MOORS RD � � 4 SITE J Z ,Q O U O 2 R= am o Z \ 3 TANGERINE RD TANGERINE RD NORTH I DRIVING DIRECTIONS I SUMMARY: FROM VERIZON OFFICE AT 126 W. GEMINI DR., TEMPE: TAKE 1-10 EAST TOWARD TUCSON; TAKE EXIT 240 FOR TANGERINE ROAD; TURN LEFT ONTO W TANGERINE ROAD; USE THE LEFT TWO LANES TO TURN LEFT ONTO E INNOVATION PARK DRIVE. MAKE A U-TURN AT VISTOSO VILLAGE DR. AND THE DESTINATION WILL BE ON THE RIGHT S10E OF THE STREET. GENERAL NOTES THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT AS SET FORTH IN THE CONSTRUCTION DRAWINGS, CONTRACT DOCUMENTS AND THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECT/ENGINEER OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF THE CONTRACTOR'S PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK UNLESS OTHERWISE DIRECTED. ORO VALLEY, AZ 85755 APN NO. R.O.W. I SITE LOCATION INFORMATION I SITE NAME: TUC-VENTANA-SC SITE ADDRESS: SWC E. INNOVATION PARK DR. & N. VISTOSO VILLAGE DR. ORO VALLEY, AZ 85755 APN NUMBER: R.O.W. SITE COORDINATES: LATITUDE: 32' 26' 24.4" N (NAD 83) LONGITUDE: 110' 56' 35.8" W (NAD 83) ELEVATION: 2,820.9' (AMSL) (NAVD 88) CURRENT ZONING: R.O.W. - NOT ZONED APPLICANT: VERIZON WIRELESS 126 WEST GEMINI DR. TEMPE, AZ 85283 CONTACT: DAN LIVINGSTON PHONE: (253) 255-6038 PROPERTY OWNER: TOWN OF ORO VALLEY OWNER CONTACT: TBD CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 2012 INTERNATIONAL BUILDING CODE (IBC) 2011 NATIONAL ELECTRICAL CODE (NEC) ANSI/EIA-222-0 STRUCTURAL STEEL STANDARDS FOR STEEL ANTENNA TOWERS AND SUPPORTING STRUCTURES STANDARD LOCAL BUILDING CODE(S) CITY AND/OR COUNTY ORDINANCES JURISDICTION: TOWN OF ORO VALLEY Two working days before you dig, CALL FOR THE BLUE STAKE! 1 (602) 263-1100 or 1 (800) STAKE -IT (782-5348) (OUTSIDE MARICOPA COUNTY) PROJECT TEAM CLIENT: VERIZON WIRELESS 126 WEST GEMINI DRIVE TEMPE; ARIZONA 85283 CONSTRUCTION MANAGER: DAN LIVINGSTON MOBILE: (253) 255-6038 RF ENGINEER: SYED NAQVI REAL ESTATE: JAMISON TYLER MOBILE: (480) 777-4336 REAL ESTATE INSITE INC. CONSULTANT: 2035 E. GONDOLA LN. GILBERT, AZ 85234 CONTACT: CHRISTINE TUCKER MOBILE: (480) 586-5180 TUCKER®INSI TE-INC. COM A&E DESIGN SIIND DESIGN MANAGEMENT 16616 EAST PALISADES BLVD, SUITE 102 PROFESSIONAL: FOUNTAIN HILLS, ARIZONA 85268 CONTACT: CHRIS M. SIINO, MBA, MSTL, PMP MOBILE: (602) 672-4311 FAX: (480) 836-1004 CIVIL ENGINEERING PNP ENGINEERING INC CONSULTANT. CONTACT: YONG-JOONG KANG, PE MOBILE: (949) 351-5020 EE CONSULTANT: JOYNGO, LLC CONTACT: TIM ALEXANDER, PE MOBILE: (602) 403-8368 PROJECT INFORMATION OCCUPANCY GROUP: U (LIGHT POLE) & S-2 (CABINET) TYPE OF CONSTRUCTION: V-B AREA OF CONSTRUCTION: 25 SQ.FT. ACCESSIBILITY DISCLAIMER THE PROPOSED PROJECT IS AN UNOCCUPIED TELECOMMUNICATIONS FACILITY AND IS NOT TO BE ACCESSED BY THE GENERAL PUBLIC. THIS FACILITY IS EXEMPT FROM DISABLED ACCESS REQUIREMENTS PER IBC 1103.2 9 LISTED AS AN EQUIPMENT SPACE. SHEETINDEX SHEET NO. SHEET DESCRIPTION T-1 TITLE SHEET LS-1 SITE SURVEY A-1 OVERALL SITE PLAN A-2 ENLARGED SITE PLAN A-3 ELEVATIONS A-4 CONSTRUCTION DETAILS I PROJECT DESCRIPTION THE PROJECT CONSISTS OF THE REMOVAL AND REPLACEMENT OF AN EXISTING LIGHT POLE WITH A NEW LIGHT POLE WITH LESSEE ANTENNA ARRAYS. IN ADDITION, INSTALLATION OF (1) NEW LOW PROFILE EQUIPMENT CABINET AND A METER PEDESTAL. THIS PROJECT DOES NOT INCLUDE WATER OR SEWER. THIS PROJECT INCLUDES PERMANENT TELEPHONE AND ELECTRICAL CONNECTIONS. DEVELOPMENT AND CONSTRUCTION OF THIS PROJECT WILL COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES. verizon 126 WEST GEMINI DRIVE TEMPE, ARIZONA 85293 PHONE: 480.752.7238 INSiinoDesign 16616 EAST PALISADES BOULEVARD UNIT #102 FOUNTAIN HILLS, ARIZONA 85268 PRONE: 480 836. 1701 FAX: 480.836.1004 WWW.SIINODESIGN.COM ENGINEERING CONSULTANT: DRAWING APPROVALS (SIGNATURES) SITE ACQUISITION/PROPERTY CONSTRUCTION MANAGER VERIZON WIRELESS RF ENGINEER LANDLORD APPROVAL DRAWN BY: TINGO CHECKED BY: CMS SCHEDULE OF REVISIONS NO DATE DESCRIPTION BY 1 07/12/17 ZONING COMMENTS CMS 0 05/10/17 1 PRELIM. CDs CMS SITE NALIE� TUC VENTANA SC SITE ADDRESS: SWC E. INNOVATION PARK DR. & N. VISTOSO VILLAGE DR. ORO VALLEY, AZ 85755 SEAL SHEET TITLE: TITLE SHEET SHEET NUMBER: T-1 CLIENT: f \ ELECTRICAL EASEMENT RECORDING NO: 2015-3360226 \ ` \ ,\ RECORDED 12/02/15 PIMA COUNTY RECORDER I � - _ 0 SEE SURVEY DETAIL I ON THIS SHEET /o/' ®/ / / �/ ;.+ • ELEC PULL 3' CHAIN BOXBE EEN / BOLLARDS -- --- ELEC PULL BOX SWG SIGN / /FIRE ET CONNECTI �O o;A: / �Sco 7 SURVEY DATE 04/22/2017 BASIS OF BEARING BEARINGS SHOWN HEREON ARE BASED UPON U.S. STATE PLANE NAD83 COORDINATE SYSTEM ARIZONA STATE PLANE COORDINATE ZONE CENTRAL, DETERMINED BY CPS OBSERVATIONS. BENCHMARK PROJECT ELEVATIONS ESTABLISHED FROM CPS DERIVED ORTHOMETRIC HEIGHTS BY APPLICATION OF NGS 'GEOID 12A' MODELED SEPARATIONS TO ELLIPSOID HEIGHTS DETERMINED BY BASELINE OBSERVATIONS OF THE AZCORS STATION AZ36 CONSTRAINING NGS RID CZ2411. ALL ELEVATIONS SHOWN HEREON ARE REFERENCED TO NAVD88. UTILITY NOTES SURVEYOR DOES NOT GUARANTEE THAT ALL UTILITIES ARE SHOWN OR THEIR LOCATIONS ARE DEFINITE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND DEVELOPER TO CONTACT BLUE STAKE AND ANY OTHER INVOLVED AGENCIES TO LOCATE ALL UTILITIES PRIOR TO CONSTRUCTION. REMOVAL, RELOCATION AND/ OR REPLACEMENT IS THE RESPONSIBILITY OF THE CONTRACTOR. SURVEYOR'S NOTES SURVEYOR HAS NOT PERFORMED A SEARCH OF PUBLIC RECORDS TO DETERMINE ANY DEFECT IN TITLE ISSUED. THE BOUNDARY SHOWN HEREON IS PLOTTED FROM RECORD INFORMATION AND DOES NOT CONSTITUTE A BOUNDARY SURVEY OF THE PROPERTY. FLOOD ZONE THIS PROJECT APPEARS TO BE LOCATED WITHIN FLOOD ZONE "X". AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN ACCORDING TO FEDERAL EMERGENCY MANAGEMENT AGENCY FLOOD INSURANCE RATE MAP(S), MAP ID #04019C1080L, DATED JUNE 16, 2011. LESSOR'S LEGAL DESCRIPTION A PORTION OF THE RIGHT OF WAY OF VISTOSO COMMERCE LOOP, ACCORDING TO THE PLAT OF RECORD IN THE OFFICE OF THE COUNTY RECORDER OF PIMA COUNTY, ARIZONA. RECORDED IN BOOK 54 OF MAPS AND PLATS, PAGE 36, ALSO DESCRIBED AS A PORTION OF THE RIGHT OF WAY OF RENAMED INNOVATION PARK DRIVE, ACCORDING TO THE PLAT OF RECORD IN THE OFFICE OF THE COUNTY RECORDER OF PIMA COUNTY, ARIZONA, RECORDED IN BOOK 56 OF MAPS AND PLATS, PAGE 65 NORM SCALE: T - 30' OVERALL DETAIL D BRASS\ FLUSH ANHOLE i i i POSITION OF GEODETIC COORDINATES LATITUDE 32. 26' 24.4" NORTH (NAD83) LONGITUDE 110. 56' 35.8" WEST (NAD83) GROUND ELEVATION ® 2820.9'(NAVD88) LEGEND AP ASPHALT ----OSTREET LIGHT BLDG TOP OF BUILDING TO AIR CONDITIONING UNIT GONG EDGE OF CONCRETE QT TELEPHONE MANHOLE D/W ACCESS DRIVEWAY FIRE HYDRANT FOR EDGE OF DIRT ROAD LIGHT POLE EP EDGE OF PAVEMENT ID ELECTRICAL TRANSFORMER FC LP FACE OF CURB LICHT POLE m UTILITY PEDESTAL - NG NATURAL GRADE ® UTILITY VAULT R/W RIGHT OF WAY V POSITION OF SL STREET LIGHT GEODETIC COORDINATES SW SIDEWALK N_1 SPOT ELEVATION TREES pQ WATER CONTROL VALVE d SHRUB CURBLINES CONCRETE LIMITS ---- ----------------------------- EXISTING BUILDINGS PARKING STRIPES v — W — v — WATER LINES GAS— GAS— SAS —CAS— GAS LINES —E —E E E —E —ELECTRIC LINES — F/0— F/a— Fi0— Fi0— Fi0— FIBER OPTIC LINES SECTION LINES - - - - — STREET CENTERLINES - -� RIGHT OF WAY LINES -- - -- --- ADJACENT PROPERTY LINE - - - - - - - - - - - - - - - - - - - - - - - - - EASEMENT LINES ------------------------ TIE LINES - - - - — - - LEASE AREA LIMITS - - - --- -- -- - - -- --- -- - - MAJOR CONTOUR INTERVAL -- --- -- ----- ----- -- --- -- MINOR CONTOUR INTERVAL \ \ ` !/ U �� O ELEC \ \ MANHOLE \ 28206FC \ \ \ 3' HIGH PVC POSTS FC ELEC EASEMENT RECORDING NO: 2822.4 \ ��A" ice, 2015-3360226 / �.`I •LNG I� \ ` NO RECORDED 12/02/15 PIMA COUNTY RECORDER Y � 1 1 Nc CONC I I \ 28207 F - NG STOP SIGN-,,,, • . - �C 9 S9F - TRAFFIC SIGNAL 1 •• ��£ : `\\ /�W/ LIGHT POLE LP - �� / '`../ TRAFFIC GRAPHIC SCALE PULL BOX � F2620 3 IN FEET) / / CONc. linch- 10 It / / 2 � yn5o nyo hf PROJECT AFEA— h 00E RD oro A, so z s 8 `'• TAN PIN R Z N IN RD VICINITY MAP N.T.S. STREET LIGHT DETAIL Z O , ELEC / MANHOLE ryry / � / / • / 1:11 TRAFFIC SIGNAL J. / F2C820 / i J NO 021411 TREE / � / CABINET CON ., '. RSA' / 6" STEEL GAS s / jPROPOSED 4, /2821 0 / DQ VERIZON WIRELESS NO / �L zula /1 '� + 28204 / F EQUIPMENT .TRAFFIC CONC U PROPOSED / / / / VERIZON / 5 yy� CENTER OF GEODETIC / o WIRELESS �,r�a'�`�/� / COORDINATES LIGHT POLE Q" METER (TO BE REPLACED) _ PEDESTAL 5 ,� SEE DETAIL ON THIS SHEET ���51 PROPOSED, ° / 28el VERIZON 0 WIRELESS c, 83 . Lp� •_ FIBER VAULT o 'SE , /S u - F2820 0 O o21m �coNc •29224. \ \ O 220 C NO / o a2 38.8 TRAFFIC "'PULL BOX / I TRAFFIC BOX '•E�E_ETPEEE ,/ 3 28198 FC verizon/ 126 WEST GEMINI DRIVE TEMPE, ARIZONA 85283 PHONE: (480) 752-7238 DESIGN MANAGEMENT PROFESSIONAL: SiinoDesign 16616 EAST PALISADES BLVD, SITE FOUNTAIN HILLS, ARIZONA 85U268 102 PHONE: (480) 836-1701 FAX: (480) 836 1004 www.d h. SURVEYING CONSULTANT: ambit consulting 410 E. SOUTHERN AVE. TEM�E, AZ 85282 PH. (480) 659-4072 DRAWING APPROVALS (SIGNATURES) SITE ACQUISITION/PROPERTY CONSTRUCTION MANAGER VERIZON WIRELESS RF ENGINEER LANDLORD APPROVAL DRAWN BY: JM CHECKED BY, MF SCHEDULE OF REVISIONS NO I DATE I DESCRIPTION I BY 2 05/31/17 ADDED ESMNT JM 1 05/10/17 ADDED DESIGN JM 0 05/02/17 IPRELIM SUBMITTAL JM SITE NAIJE TUC —VENT ANA—SC SITE ADDRESS: WEST CORNER OF E INNOVATION PARK DR. & N VISTOSO VILLAGE DR. ORO VALLEY, AZ 85755 SEAL SHEET TITLE: SITE SURVEY SHEET NUMBER: LS-1 OVERALL SITE PLAN KEY NOTES: 1. EXISTING STREET CURB 2. EXISTING CONCRETE SIDEWALK 3. APPROXIMATE LOCATION OF EXISTING U.G. GAS LINE PER BLUE STAKE MARKING 4. APPROXIMATE LOCATION OF EXISTING U.G. ELECTRICAL LINE PER BLUE STAKE MARKING 5. APPROXIMATE LOCATION OF EXISTING U.G. WATER PIPE PER BLUE STAKE MARKING 6. EXISTING ELECTRICAL PULL BOX (TYP.) 7. EXISTING FIRE DEPT. CONNECT 8. EXISTING 3' CHAIN BETWEEN BOLLARDS 9. EXISTING BUILDING 10. EXISTING ELECTRIC MANHOLE 11. EXISTING CABINET 12. EXISTING TRAFFIC PULL PDX 13. EXISTING TRAFFIC SIGNAL WITH LIGHT POLE 14. EXISTING TREE (TYP.) 15. EXISTING SHRUBS (TYP.) 16. EXISTING SIGN (TYP.) 17. EXISTING 1000kVA 277/480V TEP TRANSFORMER 18. EXISTING UTILITY EASEMENT 19. NEW U.G. CONDUIT FOR POWER RUN FROM TEP TRANSFORMER TO NEW 277/480V 100A METER PEDESTAL WITH BUILTIN STEP—DOWN TRANSFORMER APPROVED BY TEP DESIGN CRITERIA REFERENCES FOR STREET LIGHTING: 1. STREET LIGHTING DESIGN SHOULD MEET OR EXCEED THE AVERAGE ILLUMINANCE PER THE AASHTO PUBLICATION, AN INFORMATIONAL GUIDE FOR ROADWAY LIGHTING, 1984. 2. POLE LOCATIONS SHOULD BE POSITIONED BEYOND THE AASHTO CLEAR ZONE REQUIREMENTS SPECIFIED IN THE AASHTO ROADSIDE DESIGN GUIDE, 2006, UNLESS OTHERWISE DIRECTED BY TOWN OF ORO VALLEY ENGINEERING. 3. LIGHT DISTRIBUTION SHALL SATISFY THE MOST RECENT EDITION OF THE OVZCR SECTION 27.5. 4. ALL INSTALLATIONS SHALL MEET THE NATIONAL ELECTRIC CODE REQUIREMENTS. 5. INSTALLATIONS SHALL BE IN CONFORMANCE WITH THE ROADWAY LIGHTING — ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA, ANSI/IESNA RP-8, 2000. LEGEND BLDG TOP OF BUILDING •—O STREET LIGHT CLF CHAIN LINK FENCE V, FIRE HYDRANT GONG CONCRETE rQ POWER POLE D/W ACCESS DRIVEWAY POSITION OF FC FACE OF CURB GEODETIC COORDINATES NG NATURAL GRADE SPOT ELEVATION R/W RIGHT OF WAY TREES pd WATER CONTROL VALVE 4 NEW ANTENNA GROUND ROD 4.1 EXISTING ANTENNA rr GROUND BUS BAR Q REVISION MECHANICAL GRND. CONN. O CONSTRUCTION KEYED NOTE • CADWELD ® GROUND ACCESS WELL x DETAIL REFERENCE ❑c ELECTRIC BOX TELEPHONE BOX ELEVATION REFERENCE LIGHT POLE � `o' SECTION REFERENCE GRAVEL PLYWOOD GROUT OR PLASTER r—'—I (E) BRICK SAND ¢mom (E) MASONRY WOOD CONT. WOOD BLOCKING 0 CONCRETE STEEL EARTH -- --- -- -- — CHAIN LINK FENCE CURBLINES W W W WATER LINES — IRR — IRR IRR IRR IRRIGATION LINES SS SEWER ONES GAS LINES O/H O/H O/H OVERHEAD LINES — E E E E ELECTRIC ONES F/0 F/O F/0 (E) FIBER OPTIC LINES FB—FB FBF8 (N) FIBER OPTIC LINE ----- - - - - ----- STREET CENTERLINES - - - - RIGHT OF WAY LINES - - - - LEASE AREA LIMITS - — — — — — — — — - MAJOR CONTOUR INTERVAL -- --- ---- -- --- ---- ---- -- -- - MINOR CONTOUR INTERVAL OVERALL SITE PLAN Two working days before you dig, CALL FOR THE BLUE STAKE! 1 (602) 263-1100 or 1 (800) STAKE -IT (782-5348) (OUTSIDE MARICOPA COUNTY) I / S' I f / V a, !I I �P5 @ I I!•I / / w / E_/b \T / I I .i j��� . • �r I / / ENLARGED VIEW N TS CLIENT: verizon✓ 126 WEST GEMINI DRIVE TEMPE, ARIZONA 85293 PHONE: 480.752.7238 DESIGN MANAGEMENT PROFESSIONAL sSflnoDesign 16616 EAST PAUSADES BOULEVARD UNIT #102 FOUNTAIN HILLS• ARIZONA 85268 PHONE: 480.836.1701 FAX: 480.836.1004 WWW.SIINODESIGN.COM ENGINEERING CONSULTANT: \ \ I DRAWING APPROVALS (SIGNATURES) \ SITE ACQUISITION/PROPERTY GSTO CONSTRUCTION MANAGER S� `7l("fCcr O� VERIZON WIRELESS RF ENGINEER LANDLORD APPROVAL DRAWN BY: TNGO CHECKED BY: CMS SCHEDULE OF REVISIONS NOi DATE I DESCRIPTION BY NORTH 22"x34"SCALE: 1" = 30'-0" 11"x17" SCALE: 1" = 60'-0" 30 15 0. 1 07/12/17 ZONING COMMENTS ICMS 0 05/10/17 PRELIM. CDs I CMS SITE PI4I.IF: TUC_VENTANA SC SITE ADDRESS: SWC E. INNOVATION PARK DR. & N. VISTOSO VILLAGE DR. ORO VALLEY. AZ 85755 SEAL: SHEET TITLE: OVERALL SITE PLAN SHEET NUMBER: A-1 ANTENNA PLAN KEY NOTES: 1. NEW (1) ANTENNA PER SECTOR, TOTAL OF (2) SECTORS MOUNTED TO NEW REPLACEMENT LIGHT POLE Q 33'-2" RAD CENTER. 2. NEW REPLACEMENT LIGHT POLE (BELOW) WITH RF CANSITER, SEE STRUCTURAL DRAWING BY OTHERS. 3. NEW LIGHT POLE FOUNDATION, SEE STRUCTURAL DRAWING BY OTHERS. 4. NEW LOCATION OF REPLACEMENT LIGHT ARM, FIXTURE TO MATCH EXISTING AND COMPLY WITH TOWN OF ORO VALLEY AND PIMA COUNTY STANDARD DETAILS FOR PUBLIC IMPROVEMENTS. LIGHT POLE AND ANTENNA LAYOUT ANTENNA SECTION KEY NOTES: ENLARGED SITE PLAN KEY NOTES: # 9. NEW LOW PROFILE EQUIPMENT CABINET (CHARLES) MOUNTED ON 22. EXISTING TEUCRIUM X LUCIDRYS (TRAILING GERMANDER) SHRUB CLIENT: NEW CONCRETE SLAB, SEE DETAIL 2 ON SHEET A-4. (TYP.) 1. NEW 35'-0- TALL (8.625" DIA.) REPLACEMENT LIGHT POLE WITH 10. NEW (2) 4" D U.G. CONDUIT FOR COAXIAL CABLE RUNS FROM 23, EXISTING ELECTRIC CABINET MOUNTED ON CONCRETE PAD. ■ RF CANISTER, SEE STRUCTURAL DRAWING BY OTHERS. CABINET TO THROUGH LIGHT POLE FOUNDATION AND TO 24. NEW TEUCRIUM X LUCIDRYS (TRAILING GERMANDER) SHRUB TO venzon 2. NEW U.G. CONDUIT FOR POWER RUN FROM METER PEDESTAL TO ANTENNAS ON LIGHT POLE, SEE DETAIL 3 ON SHEET A-4 MATCH EXISTING (TYP, OF 5) FOR SCREENING. SEE NOTE 4 NEW CABINET, SEE DETAIL 1 ON SHEET A-4 AND SEE 11. EXISTING LIGHT POLE (8.4" DIA.), LIGHT ARM, FIXTURE & ITS 25. NEW LANDSCAPE DRIP SYSTEM TO BE CONNECTED TO EXISTING ELECTRICAL DRAWING FOR DETAIL. FOUNDATION TO BE REMOVED AND REPLACED WITH A NEW DRIP SYSTEM. SEE NOTE 4 3. NEW 277/480V 100A METER PEDESTAL WITH BUILTIN POLE WITH NEW ANTENNA ARRAYS. 126 WEST GEMINI DRIVE STEP-DOWN TRANSFORMER APPROVED BY TEP, SEE ELECTRICAL 12. APPROXIMATE LOCATION OF EXISTING U.G. ELECTRICAL LINE PER TEMPE, ARIZONA 85293 PHONE: 480.752.7238 DRAWINGS FOR DETAILS. BLUE STAKE MARKING NOTES: DESIGN MANAGEMENT PROFESSIONAL: 4. NEW U.G. CONDUIT FOR POWER RUN FROM POWER SOURCE TO 13. APPROXIMATE LOCATION OF EXISTING U.G. GAS LINE PER BLUE 1. NEW REPLACEMENT POLE TO BE PAINTED PER TOWN OF METER PEDESTAL, SEE DETAIL 1 ON SHEET A-4. FINAL STAKE MARKING ORO VALLEY REQUIREMENTS. aSiinoDesign LOCATION TO BE DETERMINED BY PROVIDER. 14. APPROXIMATE LOCATION OF EXISTING U.G. WATER PIPE PER 5. NEW U.G. CONDUIT FOR FIBER RUN FROM SITE VAULT TO NEW BLUE STAKE MARKING 2. ANTENNAS AND MOUNTING HARDWARE SHALL BE PAINTED CABINET, SEE DETAIL 1 ON SHEET A-4. 15. EXISTING TRAFFIC PULL BOX. TO MATCH LIGHT POLE COLOR. 16616 EAST PALISADES BOULEVARD 6. NEW TRAFFIC RATED FIBER SITE VAULT. FINAL LOCATION TO BE 16. EXISTING ELECTRICAL PULL BOX. 3. WHERE EXISTING CONCRETE IS TO BE REMOVED, FOUNTAIN UNITHILLSS jARIZ ARIZONA 85268 DETERMINED BY PROVIDER. 17. EXISTING STREET CURB. CONTRACTOR SHALL FOLLOW THE EXISTING CONCRETE , PHONE: 480.836.1701 7. NEW U.G. CONDUIT FOR FIBER RUN FROM MEET POINT VAULT TO SITE VAULT, SEE DETAIL 1 ON SHEET A-4. FINAL LOCATION 18. 19. EXISTING CONCRETE SIDEWALK. EXISTING ELECTRICAL MANHOLE CONTROL JOINTS AND REPLACE AND FINISH NEW CONCRETE FAX, 480.836.1004 WWW.SIINODESIGN.COM TO BE DETERMINED BY PROVIDER. 20. EXISTING TREE (TYP.) WORK TO MATCH EXISTING SURROUNDING SIDEWALKS. ENGINEERING CONSULTANT: 8. EXISTING-U.G. ELECTRIC LINE. 21. EXISTING DESERT SPOON (SOTOL) SHRUBS (TYP.) 4. NEW LANDSCAPE TO COMPLY WITH TOWN OF ORO VALLEY LANDSCAPE ORDINANCE ,9 4c, 3 w NORTH 1. NEW (2) ANTENNAS. 2 ANTENNANEW RF 2'-4" DIA. SCREEN, STRUCTURAL DRAWNG BY OTHERS. 3. NEW REPLACEMENT LIGHT POLE, SEE STRUCTURAL DRAWING BY OTHERS. 4. REPLACEMENT LIGHT ARM. 5 RAD CENTER I I 1 33'-2" A.G.L. I I I I I I I I I I I I 12 \ 3- e �V 23 /3 / �P5 `O •- / w I , � l18� 22 / w 77' 8 4�� 'o- s• ; NOTE: / 20 4 �/ 3 THE POLE SECTION, LIGHT ARM & FIXTURE 9 \ 24 / SHOWN HERE ARE FOR INFORMATION ONLY. / / / `�` / w 76• / REFER TO STRUCTURAL DRAWINGS BY / �� \ \ ! `0, OTHERS FOR POLE REPLACEMENT DETAILS ANTENNA SECTION DETAIL N.T.S. 2 NOTE: / 2 10 CONTRACTOR TO VERIFY FOR FINAL RF DATA SHEETS WITH CONSTRUCTION MANAGER PRIOR TO ANY CONSTRUCTION. NEW ANTENNA & COAXIAL CABLE TABLE SECTOR AZIMUTH q (FT) 0IOE SIZE L(FT)H COAX TYPE ALPHA 55' 33'-2" 4 }2" ±60' LDF4-50A BETA 145' 33'-2" 4 Y2" ±60' LDF4-50A ANTENNA & COAXIAL CABLE SPECS. 20 w e 7 23 I 15 , 1-E�E-_E 10- �� _ 12 N.T.S. 13 1 ENLARGED SITE PLAN 22"04" SCALE: 1/4" = i'-O" 11"z17" SCALE: 1/8" = 1'-0" 4' 3' 2' 1' O" 4' DRAWING APPROVALS (SIGNATURES) SITE ACQUISITION/PROPERTY CONSTRUCTION MANAGER VERIZON WIRELESS RF ENGINEER LANDLORD APPROVAL DRAWN BY: TNGO CHECKED BY: CMS SCHEDULE OF REVISIONS NOI DATE I DESCRIPTION IBY 1 07/12/11 ZONING COMMENTS CMS 0 15/10/17 PRELIM. CDs CMS TUC_VENTANA_SC SITE ADDRESS: SWC E. INNOVATION PARK DR. & N. VISTOSO VILLAGE DR. ORO VALLEY, AZ 85755 SEAL: SHEET TI TLF. ENLARGED SITE PLAN 9 SHEET NUMBER ELEVATION KEY NOTES:( ELEVATION KEY NOTES: ® CLIENT. 1. NEW 35'-0" TALL (8.625" DIA.) REPLACEMENT LIGHT POLE WITH RF CANISTER ON TOP, SEE STRUCTURAL DRAWING BY OTHERS. 1. NEW 35'-0" TALL (8.625" DIA.) REPLACEMENT LIGHT POLE WITH RF CANISTER ON TOP, SEE STRUCTURAL DRAWING BY OTHERS. ■ 2. NEW LESSEE (1) ANTENNA PER SECTOR, TOTAL OF (2) SECTORS MOUNTED TO NEW REPLACEMENT LIGHT POLE ® 33'-2" RAD CENTER 2. NEW LESSEE (1) ANTENNA PER SECTOR, TOTAL OF (2) SECTORS MOUNTED TO NEW REPLACEMENT LIGHT POLE ® 33'-2" RAD CENTER vel"Izon✓ 3. NEW LOCATION OF REPLACEMENT LIGHT FIXTURE 3, NEW LOCATION OF REPLACEMENT LIGHT FIXTURE 4. NEW LIGHT POLE CONCRETE FOUNDATION, SEE STRUCTURAL DRAWING BY OTHERS FOR DETAILS 4. NEW LIGHT POLE CONCRETE FOUNDATION, SEE STRUCTURAL DRAWING BY OTHERS FOR DETAILS 5. NEW LESSEE 277/480V 100A METER PEDESTAL WITH BUILTIN STEP-DOWN TRANSFORMER APPROVED BY TEP 5. NEW LESSEE 277/480V 100A METER PEDESTAL WITH BUILTIN STEP-DOWN TRANSFORMER APPROVED BY TER 6. NEW LESSEE OWNER PLAQUE ON EQUIPMENT CABINET 6. NEW LESSEE OWNER PLAQUE ON EQUIPMENT CABINET 126 WEST GEMINI DRIVE TEMPE, AR20NA 85293 7. NEW LESSEE LOW PROFILE EQUIPMENT CABINET (CHARLES) MOUNTED ON NEW CONCRETE SLAB 7. NEW LESSEE LOW PROFILE EQUIPMENT CABINET (CHARLES) MOUNTED ON NEW CONCRETE SLAB PHONE: 480.752,7238 8. NEW LESSEE GPS ANTENNA MOUNTED ON NEW CABINET 8. NEW LESSEE GPS ANTENNA MOUNTED ON NEW CABINET DESIGN MANAGEMENT PROFESSIONAL: 9. NEW (2) 4"0 U.G. CONDUITS FOR COAXIAL CABLE RUN FROM CABINET TO NEW LIGHT POLE 9. NEW (2) 4"0 U.G. CONDUITS FOR COAXIAL CABLE RUN FROM CABINET TO NEW LIGHT POLE 10. EXISTING U.G. CONDUIT FOR POWER RUN FROM EXISTING TRAFFIC PULL BOX TO NEW LIGHT POLE 10. EXISTING U.G. CONDUIT FOR POWER RUN FROM EXISTING TRAFFIC PULL BOX TO NEW LIGHT POLE SiinoDesign 11. EXISTING LIGHT POLE (8.4" DIA.), LIGHT ARM, FIXTURE & ITS FOUNDATION TO BE REMOVED AND REPLACED WITH NEW LIGHT POLE (BEYOND) 11. EXISTING LIGHT POLE (8.4" DIA.), LIGHT ARM, FIXTURE & ITS FOUNDATION TO BE REMOVED AND REPLACED WITH NEW LIGHT POLE (BEYOND) 12. EXISTING TREE (TYP.) 12. EXISTING TREE (TYP.) 16616 EAST PALISADES BOULEVARD 13. EXISTING CONCRETE SIDEWALK TO REMAIN 13. EXISTING CONCRETE SIDEWALK TO REMAIN UNIT #102 14. EXISTING STREET CURB TO REMAIN 14. EXISTING STREET CURB TO REMAIN FOUNTAIN HILLS, ARIZONA 85268 PFAX: E480.836.110041 15. EXISTING DESERT SPOON (SOTOL) SHRUBS (TYP.) 15. EXISTING DESERT SPOON (SOTOL) SHRUBS (TYP.) 16. EXISTING TEUCRIUM X LUCIDRYS (TRAILING GERMANDER) SHRUB (TYP.) 16. EXISTING TEUCRIUM X LUCIDRYS (TRAILING GERMANDER) SHRUB (TYP.) WWW.SIINODESIGN,COM 17. NEW TEUCRIUM X LUCIDRYS (TRAILING GERMANDER) SHRUB TO MATCH EXISTING (TYP. OF 5) FOR SCREENING. SEE NOTE 4 17. NEW TEUCRIUM X LUCIDRYS (TRAILING GERMANDER) SHRUB TO MATCH EXISTING (TYP. OF 5) FOR SCREENING. SEE NOTE 4 ENGINEERING CONSULTANT: 2 3 2 3 T � I II II II IIll I II � I Ijjl %" I I I1 II' II DRAWING APPRCVALS (SIGNATURES) z z uj �f z 23'-0" ARM LENGTH ¢ 1 11 SITE ACQUISITION/PROPERTY W 1 Q Ld z z N Ld H K z CONSTRUCTION MANAGER J W QI z W ¢ Li 8.625"0 z X 8-4"0 _� 8.625"0 x Of w W 0 VERIZON WIRELESS RF ENGINEER Ld o W 11 0 H � W 0 N W 0 z LANDLORD APPROVAL ¢ a = z z J X x a J z 3: I- 12 I- Of 0 ¢ z o I, L` (D J a 12 W z LL`'i Q 0 w w DRAWN BY: TNGO CHECKED BY: CMS SCHEDULE OF REVISIONS 0 0 w LLI J o z w z 0 0 a z W l� w o a NO DATE DESCRIPT ON BY Li to LLO 0 � K O Li a W W a r1 0 I v0 1- 0 cN - I 1 07/12/17 ZONING COMMENTS CMS I I - p1 0 0 ~ -. 1--n 1 M 0 05/10/17 PRELIM, CDs CMS - 1 - I 0 -In00 10 w 4 0 r1 SITE NAIAE: 5 TUC VENTANA SC 6 7 8 5 17 15 17 6 7 8 16 I 1 - - SITE ADDRESS. SWC E. INNOVATION PARK DR. & 13 .•��, ti \��i 13 14 .��1 i (. mwl ; I���A✓�� t ` P _ I �- - STOSO VILLAGE DR . ORO 1 VALLEY, IAZ 8575,5 1 I I -;.L. _J SEAL: 10 I I I I 10 I I I I I I I I I I I 4 NOTES: j (4) NOTES: I 1. NEW REPLACEMENT POLE TO BE PAINTED PER TOWN OF I 1 1. NEW REPLACEMENT POLE TO BE PAINTED PER TOWN OF L__J ORO VALLEY REQUIREMENTS. L--J ORO VALLEY REQUIREMENTS. 2, ANTENNAS AND MOUNTING HARDWARE SHALL BE PAINTED 2. ANTENNAS AND MOUNTING HARDWARE SHALL BE PAINTED TO MATCH LIGHT POLE COLOR. TO MATCH LIGHT POLE COLOR. SHEET TITLE: 3. WHERE EXISTING CONCRETE IS TO BE REMOVED, 3. WHERE EXISTING CONCRETE IS TO BE REMOVED, CONTRACTOR SHALL FOLLOW THE EXISTING CONCRETE CONTRACTOR SHALL FOLLOW THE EXISTING CONCRETE CONTROL JOINTS AND REPLACE AND FINISH NEW CONCRETE CONTROL JOINTS AND REPLACE AND FINISH NEW CONCRETE ELEVATIONS WORK TO MATCH EXISTING SURROUNDING SIDEWALKS. WORK TO MATCH EXISTING SURROUNDING SIDEWALKS. 4. NEW LANDSCAPE TO COMPLY WITH TOWN OF ORO VALLEY 4. NEW LANDSCAPE TO COMPLY WITH TOWN OF ORO VALLEY LANDSCAPE ORDINANCE LANDSCAPE ORDINANCE SHEET NUMBER: SOUTHEAST ELEVATION 22"x34" SCALE: „4" _ ' -° 1 x34" SCALE: 1/4" = 1'-0" SOUTHWEST ELEVATION 3 11"x17" SCALE: 1/8" = 1'-O" 4' 3' 2' 1' 0" 4' 11 11"x17" SCALE: 1/B" = 1'-0" 4' 3' 2" 1' 0' 4' SINGLE CONDUIT TRENCH KEY NOTES: # MULTIPLE CONDUITS TRENCH KEY NOTES: CLIENT: 1. MATCH EXISTING SURFACE AND MATERIAL, SEE PCDOT TRAFFIC 1. MATCH EXISTING SURFACE AND MATERIAL, SEE PCDOT TRAFFIC ENGINEERING SD-216 FOR DETAILS ENGINEERING SD-216 FOR DETAILS It An 2. FINISHED GRADE 2. FINISHED GRADE Y ei ZOf'1`� 3. BACKFILL MATERIAL AND COMPACTION SHALL BE IN ACCORDANCE WITH 3. BACKFILL MATERIAL AND COMPACTION SHALL BE IN ACCORDANCE WITH THE PIMA COUNTY / TOWN OF ORO VALLEY SPECIFICATIONS AND DETAILS THE PIMA COUNTY / TOWN OF ORO VALLEY SPECIFICATIONS AND 4. DETECTABLE WARNING TAPE 18" ABOVE CONDUIT DETAILS 126 WEST GEMINI DRIVE 5. SHORING, OR SLOPE SIDES PER OSHA REQUIREMENTS 4. DETECTABLE WARNING TAPE 18" ABOVE CONDUIT TPHONE:ARIZO480.7528Z383 6. BEDDING MATERIAL SHALL CONSIST OF CLASS B PORTLAND CEMENT 5. SHORING, OR SLOPE SIDES PER OSHA REQUIREMENTS DESIGN MANAGEMENT PROFESSIONAL: CONCRETE WHEN REQUIRED BY SECTION 975-3.01 (G) 6. BEDDING MATERIAL SHALL CONSIST OF CLASS B PORTLAND CEMENT 7. PLASTIC CONDUIT SPACERS, INSTALL CONDUIT AS REQUIRED TO MAINTAIN CONCRETE WHEN REQUIRED BY SECTION 975-3.01 (G) CONDUIT AUGMENT. TIE DOWN SPACERS TO PREVENT DISPLACEMENT 7. PLASTIC CONDUIT SPACERS, INSTALL CONDUIT AS REQUIRED TO S i i n o D e s i g n DURING ENCASEMENT. MAINTAIN CONDUIT AUGMENT. TIE DOWN SPACERS TO PREVENT 8. PVC CONDUIT PER SITE PLAN SPECIFICATION DISPLACEMENT DURING ENCASEMENT. 16616 EAST PALISADES BOULEVARD 2 3 B. PVC CONDUITS PER SITE PLAN SPECIE TIO UNIT #102 ARIZON70 85268 FOUNTPHONE:: 1 2 1 3 480.836. FAX: 480.836.1004 4 �l j 5 , WWW.SIINODESIGN.COM ENGINEERING CONSULTANT: - Z I 8 f7 � / i7 1 6 NOTES: NOTES: 1. THIS DETAIL NOT APPLICABLE 7 1. THIS DETAIL NOT APPLICABLE 7 TO WATER LINE(S) i TO WATER LINES) 3" 3„ 2. REFER PCDOT DETAIL # 3" 3" z 2. REFER PCDOT DETAIL # MIN. MIN. z FO-100 TYPE 1 FOR MORE MIN. MIN. " FO-100 TYPE 1 FOR MORE 3,. DETAIL DETAIL MIN. SINGLE CONDUIT TRENCH DETAIL N.T.S. 1 MULTIPLE CONDUITS TRENCH DETAIL N.T.S. 3 NOT USED N.T.S. I g CABINET CONCRETE SLAB KEYED NOTES: DRAWING APPROVALS (SIGNATURES) ® OWNER SIGN KEY NOTES: 1. OUTLINE OF CABINET. THIS CABINET IS APPROXIMATELY 44 CUBIC -FOOT 1. 6" WIDE 4" HIGH SIGN WITH BLACK SITE ACQUISIT ON/PROPERTY WITH CONCRETE PAD LETTERS ON WHITE BACKGROUND 2. 3/4" CHAMFER EDGE (TYP.) 3. LOCATION OF 3/4"0 HOLE (TYP.) CONSTRUCTION MANAGER 4. USE ITW RED HEAD TRUBOLT + WEDGE ANCHOR Yz DIA. ANCHOR BOLT W/ 6" 3Y4" MIN EMBEDMENT (TOTAL 4); VERIFY SIZE W/ MANUFACTURER SPECS. VERIZON WIRELESS RF ENGINEER 5. 3" REINFORCEMENT CLEARANCE FROM SLAB PERIMETER 6. NATURAL SOIL 7. 6" THK. MIN. CRUSHED STONE OR COMPACTED GRANULAR FILL • • LANDLORD APPROVAL 8. FINISHED GRADE LEVEL 9. 6" THK. SLAB W/ #4 @ 12" O.C. EACH WAY; SLAB FINISH 3" ABOVE GRADE DRAWN BY: TNGD CHECKED BY: CMS 10. CUTOUT IN FLOOR FOR COAXIAL CABLE STUB -UP This is an Antenna Site 11. CUTOUT IN FLOOR FOR FIBER AND POWER STUP-UP Site ID. SCHEDULE OF REVISIONS 1_g�/2" 3 For information, Call: NO DATE DESCRIPTION BY NOTES: 4 u 800-264-6620 1. VERIFY DIMENSIONS WITH 10 CABINET 1 07/12/17 ZONING COMMENTS CMS MANUFACTURER NOTE: 0 05/10/17 PRELIM. CDs CMS ALONG WITH ALL FACILITY PLAQUES TO BE n- IaI.IE LOCATION OF MOUNTED AT EQUIPMENT CABINET BASE FRAME TUC VENTANA SC OWNER SIGN N.T.S. 4 NOT USED N.T.S. 6 NOT USED N.T.S. 9 CONNECTIONS. 1 + 2. THIS CABINET IS �� - - APPROXIMATELY 35.5 CUBIC -FOOT 0-1. I SITE ADDRESS: BATTERY WARNING SIGN KEY NOTES: ® 1. RED DIAMOND SWC E. INNOVATION PARK & 1'-0" 2. YELLOW DIAMOND N. VISTOSO VILLAGE DR. O . 3BLUE DIAMOND 4. WHITE DIAMOND ORO VALLEY, AZ 85755 5. 3" X 3" DIAMOND HAZARD SIGN SEAL: BOTTOM VIEW 1 -0„ 1 0 0 2 I 1 N N 3 4 5 ELEVATION VIEW 5 �7 2 9 7 8 SHEET TITLE: 3" CONSTRUCTION H �6 N OTE: 6"2'-0"6„ �J ALL FACILITY PLAQUES TO BE ALL MOUNTED AT EQUIPMENT CABINET - SHEET NUMBER: CABINET CONCRETE SLAB DETAIL N.T.S. 2 EMERGENCY PLAQUE DETAIL N.T.S. 5 NOT USED N.T.S. 17 NOT USED N.T.S. 10 A-4 NOTICE FORM CHECKLIST OV Number: OV 1 70 ;Q3 Meeting Name & Date: Application Type: Com rn tkli CoU 011 r-A--O 15-day Notice DEADLINE: Publish in Daily Territorial Yej No Day of Publishing: 2pm submission deadline: -rS Date/Time emailed: Publishing #: 1 ,2�21 J' Cost: f 2 �� Paper copy (attached): -1 /1 i 111 Scanned to OV file: Affidavit scanned to OV file: �- -7 - Lr Original to Town Clerk: HOA Notification? No All Affected Total: �' V 1t/4 Spreadsheet into file: Date mailed out: Notification Boundary? 6;;) No nn Notification radius: feet Spreadsheet into file: Total residents: I+DA Date mailed out: Property Posting? Yes No Stickers given to Planner: Posting on Town property. Yes No Date posted: 2 Post on Planning Page? Yes No Date posted:( - Notes: '. 4 12 • JULY 21, 2017 HUD-adstida donde los solicitantest una vez Ilegando a Is parte superior de la Late de es ekgibilldad do ingraw debe ester on o dcbajo de ks hmhes de ingresos may bajos previa a la eolidtud No tengo un oomputadon on ast pore, rec&d on vale pars lxalirar so pmpio apartamento, can a otn unhlad de 0denda. comp dgar. por favor ver pdgina adjuma titulada'Sistema de documen&cida de FY puedo irpare salldtado on Una? CoAquier ordenador, amarVl— Q Vales ore poeden utilirar on cualquier lugar quo time una autoddad de vivienda con on 20171ngmws lknices 1Hsy otms factores quo podrLw hacerme tivo de Internet activado puede m ilk completer uns solidtud Pre - * pmgmma do vivienda de secci6n & inekvl)k? las biblmccas dens aceeso gratuito# FCufles son Ins atterios de eleglbilldad Para el progmma de vales do secci6n 8 vtvienda? C]iterios de ekgWWad adicionales requiere dudadania o estatus de inmigrante legal. pQuel i --16n necesito sohcitat Forma pravia a Is solicitud req—i# Para efectos de degibMW Para este . prognma, se aphcafn In aigufentes documentaddn de tarjetas de Scguro Social Para todos Ins miembros del hogar, furmar dguknte iafonnsct6n: • Nombre, rdad6n. fiche de usciu ! de6nicione8 fotmularius de consentimiento necesarios y cada miembro de le families 1. Personas soles, fandHas o personas con _ aiterlos de `Woneldae adicional que regal- • Ndmews de seguro social pan tod diyapaddad puedenviiac A. Una'fsmilis: aeon to definido por 11UD, am una verificari6n de antecedcn" pendes pan todos ks adaltos mimtbros del hogar. miembros del hogar Ingreso bruto mmsualpan el ho� incluye porn no edi llmindo a lo siguiente, independientemmte de la identidad do Awerdo con la politics STHA el dguiente to halo inelcoles de lmpuestos y otras deducciones) Pot favor tongs esta lnf nad6n da g6nero o estado dvil, orlentaci6n sesual real A. Aduhos (18 shos o mayvnx) Is negadva antes de iniclar el pro eso prevkti P una 8uia quo puede ser Pew P 4 a firmar la h'brrad6n de la forme do la in- solicitud. Forma penis a la soh*w ' uns persona endana, Persona disapaatada, formad6n; Phi 8—dar Paciahnente tcq persona carte de- ancianos o cuakpder otra persons solo; o un grupo de persona quo & Cualquia mlembro del hogar mjeto a - requldtos de registro de por vpda bajo on pro- pre-solicitud- eNecedto on Mancro de acgaro sod vh= juncos. De est. grupw cnduyen. Pero grama de rcgistro do estado sezo dellncucntq aplicar? no se limita a on& fnmft can o do hijos (un C Nadk actual m:nte involucrados en adtvi- SL todos Ins miembros del hogar oK nft quo estd tempotalmente fuera de In teen dades dellctivas relacionadas con less drogm tenor on SSN vilido. Pdngase en c3 debido a Is colocad6n en aridado de slams adhidad criminal ttolents, drogas, umduct& con el Segura Social shoe pars rare '': se considers a un m>iembro de le familia), una sexual criminal: y proceso d mt times un ndmao. farad', de Is tercera edad, one mmilia cenca D. Adualmente caakoer persona dedicada 1puede mi familia presentar mis d de ancianos, una f6milia desplazada o lxs a Is producci6n do metanfltamina colas solldtud previal a restantes ndembros de una fam0is. instalaciones der una vitdenda sststida por el No. Nomas se pawde solamente d Una SrmOle tambiin induye a dos o ends pa- sonas que no edla rdadondoz por saugm gobiemo federal 1C6mo solicitor el program& de vales de sec- pU-solicitud por familia Las [antic prescntan mis pre-splicedones peA '+ matrimonlo, adopci6n u otn opend6n do d6n 8 vivienda? deswlifiendas• Is ley, porn que tampoco Paeans demosnar Loy interesados presentardn una forma previs }Como sd d mi solidtud Previa Pas quo ban vivido anteriormente o certificar que e1 ing eso de calla individuo y otros wcursos a la soUdtud en linen enel sitio web de la . dudad de 1Lcson del sur en httpJ/south- travels del Al final del proaso pw%is, a Is solk esbu-In disponibl s Pan setisf cer las neced- tucwnmgfstha. cualquier momento. Las usted redbir6 un a mail de confirm dades de la His Personas con dlscapacidad pueden aolidtar de so presentaddn El correo cant; Cadafamilia debe identificar a los in ilviduos una pre-solicitud por Fax llamando al (520) so pre solicitud ha sido recibida R a ser induldos en Ia f unilia en el momento 623.8481 y envlar por fax so solicitud previa guerdc uoa copia del wrreo eleckd de la solicitud y deberi acludizar esta Para (520) 770.0051 o por recibir una aopia referenda future en easo de cw* informad6n d cambia Is compodci6n de Impress presolicitud on la oficfnn de SM on respecto a so aplicacidu amerim - 1, fam0ia 1713 S 3rd Avenue, South 1Lcson. AZ 85713. ILa apliad6n previa eaten dispw A 11n medio familiar con discapacidad *, La apIkad6n previa recoge_informad6a otros idioms, sparte del ln$W families cuya abeza. c6n)mp o dnico m il� -t minima sobre hogares de sohdtante a efectos SL Es en inglda y espahol juncos. St ben es una persona con disapacidad. j'uede de llevara wbo uns bterlt pars deterndnar ei nlresita ayuda con otro Idioms kg _ Induir dos o mis personas con dbxaPaddad n*wm y omen de las famihas que se atiade a tradudor a ayuda& que viven juntm o una o mis personas la Esn de apem. Si fimar el formulark de pre -solid non disapacidad que vivm con uno o m6s IQ= se realize Is Work? lines. lesto signifies rudbirin asim ayudantes Una vez quo el pcvfodo de inycripci6n previa vhienda? G Las persons con discapaddad: una a la solicited se dam Q dcAgosto de 2017 No. 1$ aphacidn previa allo it der persona qur on 5;oo PX), S19IA ekgH d azar 250 oportmn idad Paser eolocadoo a a. Time una discapacldad tal Como w define solicit rotes de todos Ins solicitudes redbidas de soliduntes que se utilizari Perri en 43 Fstados Unldos G 423; de la lista de espera nar Ia )ism de las 250 fsmilcas quo: b: Se determine con an lmpedimenm 3cdmo sabre d fur sdecctonsdo on Is l tcris enlists de espera. Se le notifies i Asico, mortal o emodsmal, en vlrtud de las quo se aaeda a la lista do esperat d f cron seleccionados a travels dad reguledones de HUD. qoe SI IU envlard on& arts en el Correa pan uo- no el sortco al a rse (1) Se esters que sea de dund6a indefinida tihcar a ada solicitante de Ins resultados de Is 1Cudndo sabr6 d he lido selecdosp y pnakngado; loteria. Ustcd redbird una art& de d fuerou aer oolocado on is We de espers? (2) Impidc cousiderabblemente so apacided o no facet seladonados en la loteria. Sl Se le enviari una arta lndiwmdo: Pam vtvir lmlependienhmem e; y ustcd es selydondo en Is loterfa• so arts seleccianados en Is loteda o no, S). (3) Es de tal mturakza que podria mljorarse tambt6n le informard de so pusid6n on la aelecdunados Pam sa coloado ca la capacidad de vtvir Independtmtemente por list& de espera debiddal order aleatoric espera, nuestra arts le permM s lea condidones do vivienda mds adecusdas; o lPor qua usas Is loteria Pam determiner I" faemn wkedonados y tambldn d& a Tiene una discapacidad del desanwk) poadones en Has de espera? INo aeria mis pasid6n do la Ifda de;gvm. coma se define en 42 Estados Unidos C. judo d it lists fuen Primer Ilegado, prim cr IEn TA Orden se coloari la pm 60001. d. No exchdr a ka personas qua lumen la wrvido? La loteria es la mis belfa mantra de dar a lids deespera? t Una vez quo Be dorm el periodo qt enfermedaddel sfndrome de inmunod•fi- tacos Opal opormuidad de ser a6adidu a is d6n prole a In wHdtud, STM m Benda adgoirida o enkrmedades derivadas lista do espera. Esto evita quo las famllias tm- lotak Easada role I>r6ormsd6m del agente cdolbgko de sindrome do inmuno- gan quo esperar horse on lium ya quo es para trade en Is spllcad6n de le format def dencia adquirida• a ser el pdmero on apliar. Aplicar temprano autumdtlamcmtc ssigoado un hW e. Pan efactua de Is alifiad6n de vtvienda no mejorard las posibilldales de alguicn de de tapers, M ..MIA tieoe preforem de bejos ingtoos, induye a Is Parson cuya ser wIcWonado Pam la loteri& Todas las berm n6meros asignados a ella is timalidez se bass dnicamento en cualqukr essay tendr6n In misma prubebilidad der ser dose en sus pmfercndas, at algma. dependencia de drogas o alcohol. selecd,nado pan la loteria independiente- automdtlamente se &dgnsrl a sue 2. Ingreso aortal bmto de Is familia de le memo de cuando se aplkau dummc Is Epvca la lists do espen. Si usted y obw4 amen is mfama puumad6n dew de de lefix-hayhon roc k— wr pretia decidlriu q ft es 1a mkil der espera. icudtWspne splimcionestotaldo se aceptarin? No hay limite pan el nfimem de q antes que el SMA acepnri SIPA permitlri s6lo una pro-solicitud. W Hogares que presmcan misde up pwvla podrin ser daali5ado selecctonann 250 la spliadonesI as loteria en lista de espaa. SComo contactar MiA d estoyte pxoblemas can In pre q&RdBo di Usced prude Lamar a STHA en (Si 8481. Ya que eanmos esperande f vol6menn de Hawed— telefdnCas la Epoea previa a Is solicitud part[ padente- Responderemos a sw j Q0 ,LEY Ati9 TOWN OF ORO VALLEY o DEVELOPMENT & INFRASTRUCTURE SERVICES DEPARTMENT 11000 N. LA CANADA DRIVE, ORO VALLEY, AZ. 85737 PHONE: (520) 229-4800 FAX: (520) 742-1022 www.orovalleyaz.gov/dis 1.2 GENERAL APPLICATION FORM office Application Type: ❑ Major General Plan Amendment ❑ Rezoning/PAD Amendment ❑ Planned Area Development ❑ Conditional Use Permit ❑ Zoning Code Amendment ❑ Conceptual Site Plan ❑ Conceptual Public Art ❑ Conceptual Architecture ❑ Final Site Plan ❑ Conceptual Landscape Plan Subiect Propertv Information: ❑ Final Plat g�� ❑ Pre -Application UNo� % ❑ Zoning Verification ❑ Sign Criteria 1y+ b bbYYYb YOeeeeeee •eeeeeee ❑ Sign - PAD Exemption ❑ Master Sign Program 21 Communication Facility — Tier 1 and 2 Minor ❑ Communication Facility — Major ❑ Revised Development Plan ❑ Other Address: 1910 1/2 E Innovation Park Dr. Parcel/Tax Code: R.O.W. Subdivision / Commercial Center Name: Book / Page or Sequence Number: Lot Number(s) Legal Description: This site lies within the Town of Oro Valley's R.O.W. Section/Township/Range: Area of Property: Existing Land Use: Public R.O.W. Proposed Land Use: Public R.O.W. Applicant Information: * If more than one, attach list Applicant *: Name: Verizon Wireless Firm. - Address: 126 W Gemini Dr City: Tempe State: AZ Zip: 85283 Telephone: Fax: Email: Property Owner(s) if different from Applicant *: Name: Town of Oro Valley Firm: Address: Telephone: Consultant: Name: Christine Tucer Address: 2035 E Gondola Ln Fax: (Discipline) Telephone: (480) 586-5180 Fax: Contact: Michael Hicks City: — Email: Firm: _ City: _ Email: 4 State: Zip: Insite Inc. Gilbert State: AZ Zip: 85234 tucker@insite-inc.com I Project Description/Narrative: The project consists of the removal and replacement of an existing light pole with a new light pole with lessee antenna arrays. In addition, installation of one (1) new low profile equipment cabinet. This project does not include water or sewer. This project does include permanent telephone and electrical connections. Development and construction of this project will comply with all applicable codes and ordinances. hereby certify that I have read and examined this application and know the same to be true and correct. I am the owner of the property or the Owner's authorized representative, and if not the owner, I have obtained the owner's permission to perform stated work. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The approval of this application does not presume to give authority to violate or cancel the provisions of any other federal, state or local law for which this project may be subject to. Notice: It is the applicant/owner's responsibility to ensure all private rules and regulations (such as Covenants, Conditions & Restrictions (CC&R's)) of the subdivision and/or commercial center are adhered to. Contact your Home Owners Association or property management to determine applicable requirements. It is also the applicant's responsibility to coordinate with all outside agencies to secure their acceptance or clearance. Failuretodo so may delay issuance of permits. See attached list of agencies. Christine Tucker 10/20/2015 Applicant's Signature Print Name Date Important Note: All submittals received after 4:00 p.m. will be processed the next day Submittals will be rejected if: • Not folded using Pima County fold & collated; • There are missing items on the checklist unless otherwise approved by Planning Division Manager or Town Engineer. • Re -submittals cannot be accepted without a transmittal and a written narrative summary describing the purpose of submittal. 5