Loading...
HomeMy WebLinkAboutOV1800091p�PAA, Zo TOWNZo OF ORO VALLEY 4 —----. � ,,, , 7 COMMUNITY DEVELOPMENT & PUBLIC WORKS DEPARTMENT 11000 N. LA CANADA DRIVE, ORO VALLEY, AZ. 85737 PHONE: (520) 229-4800 FAX: (520) 742-1022 www.orovallevaz.gov �0UAIDED �9�a 1.2 GENERAL APPLICATION FORM Office Use Only �OV Case #: QVI Application Type ❑ Major General Plan Amendment ❑ Final Plat ' ❑ Rezoning/PAD Amendment ❑ Pre -Application ❑ Planned Area Development ❑ Zoning Verification `rA �016 ❑ Conditional Use Permit ❑ Sign Criteria ❑ Zoning Code Amendment ❑ Sign - PAD Exemcr� ❑ Conceptual Site Plan ❑ Master Sign Pro -ram - ❑ Conceptual Public Art ! Communication Facility — Tier 1 and 2 Minor ❑ Conceptual Architecture ❑ Communication Facility — Major ❑ Final Site Plan ❑ Revised Development Plan ❑ Conceptual Landscape Plan ❑ Other Subject Property Information: Address: 55 E. Tangerine Road Parcel/Tax Code: 219-53-001A Subdivision / Commercial Center Name: Book / Page or Sequence Number: Docket 6745, Page 608 Lot Number(s) Legal Description: IRR PTN S2 S2 ADJ TO RD 6.77 AC SEC 36-11-13 Section/Township/Range: 36-11-13 Area of Property: 6.77 Acres Existing Land Use: R-1-144 Proposed Land Use: Applicant Information: * If more than one, attach list Applicant *: Name: Sprint Spectrum, LP Firm: c/o Smartlink, LLC ATTN: Janet C. McClendon Address: 8502 E. Via de Ventura, Suite 220 City: Scottsdale State: AZ Zip: 85260 Telephone: 205-240-1360 Fax: Email: Janet.mcclendon@smartlinklic.com Property Owner(s) if different from Applicant *: Name: Tucson Electric Power Co. Firm: ATTN: Daniel Madril Address: 4350 E. Irvington Road, Mailstop OH204 City: Tucson State: AZ Zip: 85714 Telephone: 520-661-9460 Fax: Email: dmandril@TEP.com Consultant: Design Firm (Discipline) Name: WYCO Field Services Firm: ATTN: Christ Wolfe Address: c/o 2227 W Pecos Road, Suite 4 City: Chandler State: AZ Zip: 85224 Telephone: 602-281-0223 Fax: Email: cwolfe@wycofs.com 1 Project Description/Narrative: This application is for a modification to Sprint's Existing Array located on an existing 38' Monopole Site. There will be no changes to the existing Wireless Communication Facility. Application is for minor enhancements to existing Facility and modification will enhance service for surrounding Fesidenees, b ^end-eater-gert eal Stealth -applieatTents..?'�1— be mad;-, acllldincl repainting the (e anti antennas, and encasing the cahles I hereby certify that I have read and examined this application and know the same to be true and correct. I am the owner of the property or the Owners authorized representative, and if not the owner, I have obtained the owner's permission to perform stated work. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The approval of this application does not presume to give authority to violate or cancel the provisions of any other federal, state or local law for which this project may be subject to. Notice: It is the applicant/owner's responsibility to ensure all private rules and regulations (such as Covenants, Conditions & Restrictions (CC&R's)) of the subdivision and/or commercial center are adhered to. Contact your Home Owners Association or property management to determine applicable requirements. It is also the applicant's responsibility to coordinate with all outside agencies to secure their acceptance or clearance. Failure to do so may delay issuance of permits. See attached list of agencies. Applicant's Signature Janet C. McClendon Print Name Important Note: All submittals received after 4:00 p.m. will be processed the next day Submittals will be reiected if: 1/10/2018 Date • Not folded using Pima County fold & collated; • There are missing items on the checklist unless otherwise approved by Planning and Zoning Administrator or Town Engineer. • Re -submittals cannot be accepted without a transmittal and a written response to staff comments. I @smartiink VIA HAND DELIVERY Tuesday, January 09, 2018 Ms. Milini Simms City of Oro Valley 11000 N. La Canada Drive Oro Valley, Arizona 85737 RE: Communication Facility application Sprint PH63XC506-A— FILL-IN—TUC015 Address: 55 E. Tangerine Road, Oro Valley, AZ 85737 Ms. Simms: Pursuant to your recent telephone call and follow-up email, we are re -submitting the Zoning Application for the above -referenced Wireless Telecommunications Facility (WTF). We have revised the application to include a proposed cable shroud, mounted to the side of the Existing WTF, and all painted to match (per local jurisdiction requirements.) In connection with the aforementioned, enclosed are two (2) sets of the following documents enclosed: 1. Check 91367 in the amount of $300.00 2. Town of Oro Valley 1.2 General Application Form Communication Facilities: 3. Submittal Narrative; includes: Written description of proposed facility including antennas and ground equipment Pima County Zoning Information Previous Zoning Approval 8.5 X 11 Photo SIM 4. Zoning Drawings Please direct any inquiries to my attention; you may reach me by phone (205-240-1360) or via email (ianet. mcclendon@smartlinkllc.com). On behalf of Sprint and in advance, thank you. J et Clendon 10 F Sma nk LC �`� Phone: (205) 240-1360 Email: janet.mcclendon@smartlinklic.com �''••..',� 8502 East Via de Ventura, Suite 220, Scottsdale, AZ 85258 p 480.878.4881 smartlin!<Ilc.com bA Town of Oro Valley — Tier II Review Project Submittal Narrative PH63XC506-A —Crown Oro Valley 55 E. Tangerine Road, Oro Valley, AZ 85737 .3 lid runIn LU- @smarthink 3 8502 East Via de Ventura, Suite 220, Scottsdale, AZ 8525 Janet McClendon / (205) 240-1360 m net.mcclendon@smartlin hu �oiav4dxeea�•aca."' Wednesday, January 10, 2018 Town of Oro Valley —Tier II Review PH63XC506-A—Crown Oro Valley Sprint Antenna Modification for Existing Wireless Telecommunication Facility PH63XC506-A / Crown Oro Valley 55 E. Tangerine Road, Oro Valley, AZ 85737/ APN 219-53-001A Zoning Drawings The Zoning Drawings dated January 9, 2018 (hereinafter referred to as the "Drawings"), which accompany the application include the following: ✓ Title Sheet (Sheet T1) ✓ Site Plan (Sheet Al) Enlarged Site Plan; Equipment Plan and Antenna Layout (Sheet A3) ✓ Elevations— Existing and New (Sheet A4) Exhibits The following Exhibits are attached hereto and by reference incorporated herein: Exhibit "A" Aerial Photo & Photo of the Compound Exhibit "B" Pima County Assessor Information & Map Exhibit "C" PhotoSim of the Facility (Before and After) Exhibit "D" Zoning Approval (1/31/2014) Basic & Historical Information The following Exhibits are attached hereto and by reference incorporated herein: Address (E911 Address) 55 E. Tangerine Road, Oro Valley, AZ 85737 County Pima APN 219-53-001A Zoning R1-144 Related Cases Reference No. MB1300486 Description of the Existing Wireless Telecommunications Facility This application is for a modification to a Sprint's Existing Array located on an Existing 38' Monopole (herein after referred to as the Existing WTF). The Existing WTF does and will continue not to have any impact to vehicular or pedestrian pattern (parking); it does not and will not utilize any connections to any water or sewer system or refuse collection. The Existing and Proposed equipment does not and will not emit any odor, dust, gas, noise, vibration, smoke, heat or glare. Zoning & Land Uses of the Subiect Parcel & Adiacent Property The Existing WTF is situated off E. Tangerine Road and West of N. Rancho Viistoso Blvd.; it is surrounded primarily by single family residences with a presence of light commercial. Both ground equipment and the Pole are located within the Tucson Electric Power Company Tangerine substation. The WTF is owned by Tucson Electric Power Co. Sprint's Antenna Array ➢ Purpose of Modification The proposed modification will handle the additional demand for wireless data and voice service for the surrounding area- particularly for residents, emergency personnel and businesses; furthermore, the new antennas and equipment at this site will incorporate the new E-911 call tracking requirement by the FCC. i Sprint's Existing Array: Sprint's Existing Array is comprised of the following: (3) Sprint Antennas mounted at 35' (3) RRH's on the Base of the Pole (9) 7/8" Coax Cables / (3) Hybriflex Cables ➢ Sprint's Scope of Work: Permit will cover the following work to be completed: Install (6) New Antennas, (2) Per Sector Relocate (3) Existing RRHs (from the Base of Pole to the Top behind Panels)* Install (9) New RRH's, (3) Per Sector .Remove Existing (9) 7/8" Coax Cables Install (4) New 1-1/4" Hybriflex Cable / Install (1) New 5/8" Fiber Line Install (1) New Cable Shroud D Sprint's Proposed Arrav: Sprint's Proposed Array shall be comprised of the following: (9) Antennas, (3) Per Sector (12) RRH's, (4) Per Sector (4) 1-1/4" Hybriflex Cables / (1) 5/8" Fiber Line * Per TEP Requirement Mount Per Sheet A3 of the CD's, the mount will be replaced since the SOW calls to increase from Panels to 9 Panels. The proposed mount has an 18" Standoff and has a width of 4'6"; this is the tightest mount which can accommodate the proposed equipment. Stealth Applications To minimize the overall impact of the modification, the CD's indicated the Existing WTF: 1. Paint the Shaft of the Pole; all Antennas and Auxiliary Equipment 2. Install a cable shroud (in the event the cables cannot be ran to the inside of the pole) Sprint's Compound: Ground Equipment There will be no change to the size or dimension to the Lease Area as demonstrated on the Enlarged Site Plan on Sheet Al and the Equipment Plan on Sheet A2 of the Drawings; a photo of the Ground Equipment, which is located within the TEP Tangerine Substation (completely screened), a photo of the Equipment from inside the substation is located on Exhibit "A". Access to the Antenna's and Sprint's Ground Equipment is and will continue to be limited to Authorized Personnel only. Conclusion: No Substantial Change Sprint's Proposed Modification under this application, as described above and supplemented by the Drawings, will not Substantially Change** the physical dimensions of the Existing WTF — as summarized below: No Change to the Centerline of 35' No Increase in the Height of the Tower —Remain at 38' All Existing / Proposed Auxiliary Equipment (RRH's) Shall be Screened /Installed behind the Antenna All Proposed Cables to Run to the Existing Pole (or screened with cable shroud) ** As defined by Section 6409 of the Middle Class Tax Relief and Job Creation Act of 2012 Exhibit "A" Aerial Photo / Source: Pima County GIS Sprint Equipment (screened behind the walls of the Substation) / Source: Sprint WApN1�MG ASSESSOR'S RECORD MAP 219-53 SECTION 36, TOWNSHIP 11 SOUTH, -5 -54 I II I � ' / 1 I N 89-40-48 E (S) 2633.55_(S) FORMERLY MOORE ROAD 202-77 VISTOSO RIDGE 1 Lors 3s1. RANCHO 1 & C.A.••A 53/083 M&P VISTOSO (210-50) NEIGHBORHOOD 7 Aj 4 C. fi PARCEL "A" GflI.DER RANCH � FIRE DlS1RlCT s VIST090 POINTE LOTS I Z. C.A. "A & B" 3, m, 11&P 56/022 EIC � YN i ao/o (219-50) -b ^TS 1 RANGE 13 EAST RANCHO VISTOSO NEIGHBORHOOD 7, PARCEL K N 89-50-40 E (S) LOTS I-3D 263573'(S) 50/18 N&P 1 u. I nwom Hiroo° 5 PLACE O� 1 40, I P ,�� o 6 F 577� O VISTO50 HILLS a� �wce 3B ' P Isr yroa`� ao 0 713.63 LOTS 1-63 I L=500.94' I N 1 a, q& C.A."A & B" 6/ors- '6B4.86' 7 M&P a+s "dry F RC DISZRTCi °fi z � ,e� N"� ai RAN 'NE F wuwuerte novae r� C7 1 x 36.25' I a n uP i d 1� ,L� ",r •n� I LOT 1m nrrartun rucn `I & �-' t•�j� � u_ O 5�853� ; NOW COYOTE RIDGE m THE OVERLOOK AT " 1r J RANCHO VISTOSO I % 9 LOTS 158- o NEIGHBORHOOD 7 a DSO 268 PARCEL F I 16j94. ip LOTS 1-179 om @ bN \ p 51/059 M&P - i-- 100.' v 6B o 9 a 72.27' DETAIL B 1"=150' R=25 L=38.B7' .lZ.422 W •D�' J 4T P v r N A DETAIL A 1 "=300' -9e.lo' °�-eo.s6• �� 50.64'- t19.3P`5Z8 f ASSESSED WITH s SEC 31-11-14 219-54-0030 3B ,ZpAS H R•1075 a, L=169.50 4 m DETAIL C N 1 '= 600' w iLzIl!"I"21 2L2G�L=678.871' 3.46• 2� 1391.29' 62.0 87980' I��� / ry TANGERINE ROAD ------y---------R-LQ7ZQ0l----------------- --------------------------------------------------------------- - 2633.05'(S) T111336 2674.53'tS) I N 89-59-31 V (S> S 09-32-21 Y (S) _ m LACE d i r E 6G �A NOW �K o N SS/ RANCHD G- V19T050 ��a•-r=34\�" •� OFFICE SEE 6'y PARK DETAIL ?�y, UNITS IA-5D VISTOSO B' N&P 67/039 (219- 4) 0 N 6D PARCEL T aN �.------ ----- VEIGt HOOD 5 1-120 4ja & C.A."A" H 129 a- 2015-1 I\ills\I113E36- 10/23/14 5l 0 300 600 900 1?00 FEET Pima County - Parcel Detail Pima County Geographic Information Systems Parcel 2 19-53-OOIA Read the Disclaimer. Information on this pace is unofficial NIail name and address Legal description 219-53-OOIA IRR PTN S2 S2 ADJ TO RD 6.77 AC SEC 36-11-13 UNISOURCE ENERGY CORP TOTAL VALUE OF OPERATING PROPERTY ATTN: TAX DIRECTOR TAXPAYER GROUP NO 660 MAIL STOP HQW802 PO BOX 711 TUCSON AZ 85702-0711 Situs (property) address (:\hoot citus addresses) Street Address Jurisdiction Postal City Zip Code There is no sites address information. Information for this parcel • For Assessor parcel details, copy and paste Parcel ID 219-53001A into the Pima County Assessor's "Quick Search". We cannot link directly. Also see Assessor Record Mans. Real Estate Property Tax Inquttvv and PropertyTax Statement from the Pima Count;• Treasurers's Office. • Recorded Information from the Pima Count Recorder's Office o Recorded Document for Docket 6745, Page 60S. o Voter Precinct and Districts are not available because there is no parcel sites address information. • A Subdivision Plat Map is not available here because the GIS parcel record does not have subdivision Book/Page or Sequence numbers. The parcel may have an associated subdivision Book/Page or Sequence number that isn't documented here. See "Subdivision" in the "Development" GIS overlay details group results. As another option, the parcel legal description above may have a subdivision name you can search for in Subdivision Final Plats. e Pima County Sanituy Sewer Connection Search from the Pima County Regional Wastewater Reclamation Departrnent • Permits from Pima County Development Services o Permit Database Search • Historical Pennit Cards - Prior to about 1998 • City ofTueson Development Activity Records are not available because the parcel is not in the City of Tucson. file: C l!sers'lanet.Mcelendon Document; 111-163XC506-A'!o20Fill-Itt""20IVC15 Pima"n20Counh'"o2ll-"„2OParcel''o2UDctaiHum [[11) 30 2017 2:17:20 P\11 Pima County - Parcel Detail • Section Information and hjats for Township I IS, Range BE, Section 36. This parcel's GIS overlie details Grids group is a more complete analysis of sections when parcel boundaries extend outside of the listed section. • Floodplain Information from the Pima Count' Regional Flood Control District o Pa reel Floodllain Inlbrmation. See FENUN Digital Flood IIISLIranee Rate Maps (DFIR Ms) for more. • Town of Oro Valley jurisdiction. Call (520) 229-4818. • ZoomTucson is not available because there is no parcel situs address information. Over 100 parcel details from GIS overlay analysis Learn more about parcel GIS overlay details. See a list of all details. AiLport fUds Schoole Associations incentive Zones Sonoran Desert Conservation Plan Census Jurisdictions Comprehensive Plan Pima Prosper ti Landscape Classifications Transportation DevelopmentDevelol2ment Utilities Floodplain Defined by Pima County RF D \Miscellanenu Zoning Other Regulato(v Areas Floodplain FEMA PC Gov. Property Rights Governmental Districts and Areas Public Sa[ety Parcel GIS geometry details Accuracy is limited to that of the GIS parcel data. All data is subject to this disclaimer. Parcel centroid coordinates Approximately 32.425121 degrees latitude,-110.969790 degrees longitude. Parcel area This is only an estimate from GIS data. The Subdivision Plat Map, if any, may also specify parcel area. See Finding Parcel f\teas. Approximately 6.76 acres or 294,546 square feet. Zoom to maps of the parcel's area o Main ma . I o Main maid o Orthophoto map City of Tucson o tMapTucson Oblique Aerial Photos You can change the view (N,S,E,W) or pan and zoom the oblique photo. If the parcel centroid is outside the oblique photo area, either a flat map is shown or the page remains empty. PICTOMETRY Pic on cdi:y Pl�tis t Legacy Internet Explorer Viewer) Learn more Go -31t Area Map :MAI"WEST'"; Area Mali binu Area Map file: C Users.Jane0leclendon Documents PH63\C506-A' 1,2Ol.ill-In",,20'1I'CI5 Ili ma",,20Cuuugv"„20-"v20Parcel"u20DetA.hunl(10 30 2017 2:17:211 P\IJ qa a oil SHno0esign . (n ch r—t- X In Ln Lno t� rn � �D W( in N (DLn 0 ch G t�D Q. 41� I p' O o O 1' d � r � o� o D C w `y o 00 Ln N V v W o -J Simulation By: Christopher M. Siino, MBA, MSTL, PMP, MCP - csiino@siinodesign.com Charles Chisholm From: Arellano, Rosevelt <rarellano@orovalleyaz.gov> Sent: Friday, January 31, 2014 3:29 PM To: Charles Chisholm Subject: RE: PH63XC506 - OV113-032 - 55 E. Tangerine Rd., Oro Valley, AZ 85737 Follow Up Flag: Follow up Flag Status: Flagged Chuck, The proposed tower modifications can be processed with a Building Permit application. Subsequent to receiving the Building Permit application, the Town's Zoning Staff will review the application to ensure that the design still meets the Zoning Code for a Tier 1 Communication Facility. Please let me know if you have any more questions. Rosevelt Arellano Planner Development and Infrastructure Services Town of Oro Valley Office: (520) 229-4817 Fax: (520) 742-1022 www.orovallevDIS.com Caring for our heritage, our conununity, ow- fattiu-e. From: Charles Chisholm [mailto:charleschisholm@clearblueservices.com] Sent: Friday, January 31, 2014 3:22 PM To: Arellano, Rosevelt Subject: RE: PH63XC506 - OV113-032 - 55 E. Tangerine Rd., Oro Valley, AZ 85737 Rosevelt, Just so I am clear, does your email below mean that as far as zoning goes the site is approved to go to building permit application and that we do not need any further zoning approval? Chuck Chisholm Project Manager Clear Blue Services 602-426-9500 CharlesChisholm@clearblueservices.com Q- Clear BlUe From: Arellano, Rosevelt [maiIto: rarellano@orovalleyaz.gov] Sent: Friday, January 31, 2014 9:49 AM To: Charles Chisholm Subject: RE: PH63XC506 - OV113-032 - 55 E. Tangerine Rd., Oro Valley, AZ 85737 Chuck, Good news! The Planning Staff has determined that your proposed modifications meet the Tier 1 Minor Communication Facility requirements. Please note that the proposed antenna arrays must be painted an earth tone color. This earth tone color shall take into consideration the adjacent neighbors' views from the northwest. . If you have any questions, please contact me. Rosevelt Arellano Planner Development and Infrastructure Services Town of Oro Valley Office: (520) 229-4817 Fax: (520) 742-1022 www.orovallevDIS.com Caring for our heritage, our conznitazhy, our future. From: Charles Chisholm (ma !Ito:charleschisholm(c clearblueservices.coml Sent: Wednesday, January 22, 2014 3:11 PM To: Arellano, Rosevelt Subject: RE: PH63XC506 - OV113-032 - 55 E. Tangerine Rd., Oro Valley, AZ 85737 Rosevelt, We have revised our proposal for the above referenced site based on the meeting I had with you last month. As you can see from the attached photosim, we have altered the proposal so that it is more stealth in an effort to qualify the site for a Tier 1 consideration. The changes from the plan you previously reviewed are as follows: The remote radio heads (RRH units) have been lowered on the pole to a height below the height of the existing CMU wall so they cannot be seen from outside of the substation. The antennas have been designed with a stealth component so that they appear as a more monolithic extension of the pole rather than individual antennas. Please review the attached photosim and let me know if this can receive a Tier 1 administrative approval. Thank you, Chuck Chisholm Project Manager Clear Blue Services 602-426-9500 CharlesChisholm@clearblueservices.com Q-D rlCas' Gfue Sprint ARIZONA STATE CODE COMPLIANCE: ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 2012 INTERNATIONAL BUILDING CODE 2012 INTERNATIONAL MECHANICAL CODE 2011 NATIONAL ELECTRICAL CODE/NFPA-70 ACCESSIBILITY REQUIREMENTS: THIS FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS REQUIREMENTS ARE NOT REQUIRED IN ACCORDANCE WITH THE CURRENT INTERNATIONAL BUILDING CODE. I, CODE BLOCK J APPROVAL SIGNATURE DATE SITE ACQUISITION s ZONING CONsrRu ERON ►I ER A&E MANAGER PLANNING CONSULTANT RF MANAGER PROPERTY OWNER SPRINT REPRESENTATIVE SIGNATURE BLOCK FROM THE SPRINT OFFICE IN PHOENIX, AZ DO MACRO UPGRADE CROWN ORO .'ALLEY PH 63XC506-A 55 E. TANGERINE RD ORO VALLEY, AZ 85737 LATITUDE: 32° 25' 31.3"N LONGITUDE: 1 10°58' 13.0"W TUCSON MARKET FOLLOW N TATUM BLVD AND N 44TH ST TO AZ-143 S/STATE HWY 143 S/HOHOKAM EXPY (10.0 MI), HEAD NORTHWEST ON N TATUM BLVD TOWARD E PARADISE VILLAGE PKWY S (0.1 MI), MAKE A U-TURN AT E PARADISE VILLAGE PKWY S (5.0 MI), CONTINUE ONTO E MCDONALD DR (0.7 MI), CONTINUE ONTO N 44TH ST (1.9 MI), CONTINUE STRAIGHT TO STAY ON N 44TH ST (2.0 MI), USE THE LEFT 2 LANES TO TURN LEFT ONTO E MCDOWELL RD (0.3 MI), FOLLOW 1-10 E TO W TANGERINE RD IN MARANA. TAKE EXIT 240 FROM 1-10 E (91.5 MI), TURN RIGHT ONTO AZ-143 S/STATE HWY 143 S/HOHOKAM EXPY (SIGNS FOR STATE HWY 202) CONTINUE TO FOLLOW AZ-143 S/STATE HWY 143 S (3.8 MI), TAKE EXIT 1A FOR INTERSTATE 10 E/US 60 E TOWARD TUCSON (0.8 MI), MERGE ONTO 1-10 E/US-60 E (0.9 MI), KEEP LEFT AT THE FORK TO CONTINUE ON 1-10 E (6.1 MI), CONTINUE STRAIGHT TO STAY ON 1-10 E (79.6 MI), TAKE EXIT 240 FOR TANGERINE RD (0.4 MI), CONTINUE ON W TANGERINE RD. TAKE W MOORE RD TO N JARREN CANYON WAY IN ORO VALLEY (13.5 MI), TURN LEFT ONTO W TANGERINE RD (5.0 MI), TURN LEFT ONTO N DOVE MOUNTAIN BLVD (1.5 MI), TURN RIGHT ONTO W MOORE RD (5.9 MI), TURN RIGHT ONTO N WOODBURNE AVE (0.9 MI), TURN RIGHT ONTO W FREDDIE CANYON WAY (233 FT), TURN LEFT ONTO N JARREN CANYON WAY DESTINATION WILL BE ON THE LEFT (466 FT) LDRIVING DIRECTIONS J SPRINT PROPOSED THE FOLLOWING: REMOVE EXISTING CABINETS REMOVE EXISTING (9) 7/8" COAX CABLES RELOCATE EXISTING 1900 RRHS TO NEW MOUNT ADD NEW ANTENNA MOUNT ADD (6) NEW ANTENNAS, (2) PER SECTOR ADIT C4)-NEW 1 - 1/4- -HYBRPLEX CABLE ADD (1) NEW 5/8" FIBER LINE ADD (1) 9927 MMBTS CABINET W/ 2.5 CARD ADD (1) 48V BATTERY CABINET. FILL TO CAPACITY I PROJECT DESCRIPTION J APPLICANT: SPRINT C/O SMARTLINK LLC. 8502 E VIA DE VENTURA, SUITE 220 SCOTTSDALE. AZ 85258 CONTACT: PATRICIA RAMSEY PHONE: (480) 206-9896 PROPERTY OWNER: COMPANY: TUCSON ELECTRIC POWER CO. ADDRESS: 4350 E. IRVINGTON RD, MAILSTOP 01-12O4 TUCSON AZ 85714 CONTACT: DANIEL WRIL PHONE: 520-661-9460 EMAIL DMADRIL®TEP.COM ZONING CLASSIFICATION: R1-144 JURISDICTION: TOWN OF ORO VALLEY EXISTING/NEW USE: UNMANNED WIRELESS TELECOMMUNICATIONS FACILITY PARCEL NUMBER 219-53-001A I PROJECT SUMMARY J SHEET DESCRIPTI01N T-1 TITLE SHEET, VICINITY MAP AND GENERAL INFORMATION SP-1 SPRINT SPECIFICATIONS SP-2 SPRINT SPECIFICATIONS, ENGINEERS AND UTILITY NOTES CIVIL PLANS A-1 OVERALL SITE PLAN A-3 aMlING/FINAL EQUIPMENT AND ANTENNA PLAN A-4 E)=NG/FINAL ELEVATION A-6 EQUIPMENT DETAILS A-6 MOUNT DETAIL A-7 RRH CABLE MARKING LOCATIONS A-B 1 EQUIPMENT k CONSTRUCTION DETAILS ELECTRICAL PLANS E-1 1-UNE DIAGRAM. PANT SCHEDULE, ELECTRICAL PLAN & NOTES SHEETINDEX CLIENT: SPRINT 11811 NORTH TATUM BLVD. SUITE P155 PHOENIX, AZ. 85028 CONTACT. TERRY DUFFIELD PHONE: (801) 654-9999 SITE ACQ. CONSULTANT: SMARTLINK LLC. 8502 E VIA DE VENTURA, SUITE 220 SCOTTSDALE, AZ 85258 CONTACT: PATRICIA RAMSEY PHONE: (480) 206-9896 DESIGN FIRM: WYCO FIELD SERVICES 2227 W PECOS RD, SUITE 4 CHANDLER, AZ 85224 CONTACT: CHRIS WOLFE PHONE: (602) 281-0223 CIVIL ENGINEER: AMMTEC CONSULTANTS 2447 W 12TH ST SUITE #1 CONTACT: ALAN MONEY PHONE: (480) 927-9696 911 - I zq� 10 R Know what's -below. Call before you dip 1-800-424-5555 l PROJECT TEAM J Sprint° )P-) Together with Nextel. smart3 8502 E VIA DE VENTURA, SUITE 220 SCOTTSDALE, AZ 85258 X1, FIELD SERVICES 11 here quality still counts. 2227 W PECOS RD, SUITE 4 CHANDLER, AZ 85224 ; ` soej ° "_ i 9� p Fiwms i�TI� A 109/26/171 90% CO'S B 109/27/171CUENT COMMENTSIAPRI C 10/18/17 SOW CHANGES CW 0 11/28/17 SUBMITTAL CD'S CW �1 01/09/18 JX COMMENTS CW CROWN ORO VALLEY PH63XC506-A 55 E. TANGERINE RD ORO VALLEY, AZ 8573 TE4I Etf , VI ITY MAP & GENERL INFO. ° T-1 THESE OUTLINES SPECS IN CONJUNCTION WITH THE SPRINT STANDARD CONSTRUCTION SPECS, INCLUDING CONTRACT DOCUMENTS AND THE CONSTRUCTION DRAWINGS DESCRIBE THE WORK TO BE PERFORMED BY THE CONTRACTOR. SECTION 01 100 - SCOPE OF WORK SHALL COMPLY WITH APPLICABLE NATIONAL CODES AND STANDARDS, LATEST EDITION, AND PORTIONS THEREOF. PRECEDENCE: SHOULD CONFLICTS OCCUR BETWEEN THE STANDARD CONSTRUCTION SPECIFICATIONS FOR WIRELESS SITES INCLUDING THE STANDARD CONSTRUCTION DETAILS FOR WIRELESS SITES AND THE CONSTRUCTION DRAWINGS, INFORMATION ON THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE SITE FAMILIARITY, CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS PRIOR TO PROCEEDING WITH CONSTRUCTION. ON -SITE SUPERVISION: THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. DRAWINGS. SPECIFICATIONS AND DETAILS THE CONSTRUCTION CONTRACTOR SHALL NTAIN A FULL SET OF THE CONSTRUCTION DRAWINGS AT THE JOBSITE FROM MOBILIZATION THROUGH CONSTRUCTION COMPLETION. A. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO PROVIDE A COMPLETE AND FUNCTIONING SYSTEM. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. B. CONTRACTOR SHALL NOTIFY SPRINT CONSTRUCTION MANAGER OF ANY VARIATIONS PRIOR TO PROCEEDING WITH THE WORK.DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS NOTED OTHERWISE MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. C. MARK THE FIELD SET OF DRAWINGS IN RED, DOCUMENTING ANY CHANGES FROM THE CONSTRUCTION DOCUMENTS. METHODS OF PROCEDURE CONTRACTOR SHALL PERFOR WORK AS DESCRIBED IN A COAX COLOR CODING SWEEPS AND FIBER TESTING TS-0200 AND EL-0568 B. CABLE LABELING EN-2012-00 C. APPLICABLE INSTALLATION MOPS IDENTIFIED ELSEWHERE IN THE CONTRACT DOCUMENTS CTION 01 200 - COMPANY FURNISHED MATERIAL AND EQUIPMENT COMPANY FURNISHED MATERIAL AND EQUIPMENT IS IDENTIFIED ON THE RF DATA SHEET IN THE CONSTRUCTION DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR SPRINT PROVIDED MATERIAL AND EQUIPMENT TO ENSURE IT IS PROTECTED AND HANDLED PROPERLY THROUGHOUT THE CONSTRUCTION DURATION. CONTRACTOR RESPONSIBLE FOR RECEIPT OF SPRINT FURNISHED EQUIPMENT AT CELL SITE OR CONTRACTORS LOCATION. CONTRACTOR TO COMPLETE SHIPPING AND RECEIPT DOCUMENTATION IN ACCORDANCE WITH COMPANY PRACTICE. SECTION 01 300 - CELL SITE CONSTRUCTION NOTICE TO PROCEED: NO WORK SHALL COMMENCE PRIOR TO COMPANYS WRITTEN NOTICE TO PROCEED AND THE ISSUANCE OF WORK ORDER. SITE CLEANLINESS: CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH. AT THE COMPLETION OF THE WORK, CONTRACTOR SHALL REMOVE FROM THE SITE ALL REMAINING RUBBISH, IMPLEMENTS, TEMPORARY FACILITIES, AND SURPLUS MATERIALS, SECTION 01 400 - SUBMITTALS & TESTS AT THE COMPANY'S REQUEST, ANY ALTERNATIVES TO THE MATERIALS OR METHODS SPECIFIED SHALL BE SUBMITTED TO SPRINTS CONSTRUCTION MANAGER FOR APPROVAL SPRINT WILL REVIEW AND APPROVE ONLY THOSE REQUESTS MADE IN WRITING. NO VERBAL APPROVALS WILL BE CONSIDERED, TESTS AND INSPECTIONS: A THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION TESTS, INSPECTIONS AND PROJECT DOCUMENTATION. B. CONTRACTOR SHALL ACCOMPLISH TESTING INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 1. COAX SWEEPS AND FIBER TESTS PER TS-0200 REV 4 ANTENNA LINE ACCEPTANCE STANDARDS. 2. AGL, AZIMUTH AND DOY�NTILT PROVIDE AN AUTOMATED REPORT UPLOADED TO SITERRA USING A COMMERCIAL MADE -FOR THE PURPOSE ELECTRONIC ANTENNA ALIGNMENT TOOL (AAT). INSTALLED AZIMUTH, CENTERLINE AND DOWNTILT MUST CONFORM WITH RF CONFIGURATION DATA 3. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL CORRECTIONS TO ANY WORK IDENTIFIED AS UNACCEPTABLE IN SITE INSPECTION ACTIVITIES AND/OR AS A RESULT OF TESTING. 4. ALL TESTING REQUIRED BY APPUCA13LE INSTALLATION MOPS. C. REQUIRED CLOSEOUT DOCUMENTATION INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING; 1. AZIMUTH, DOWNTILT. AGL FROM SUNSIGHT INSTRUMENTS - ANTENNALIGN ALIGNMENT TOOL (AAT) 2. SWEEP AND FIBER TESTS 3. SCALABLE BARCODE PHOTOGRAPHS OF TOWER TOP AND INACCESSIBLE SERIALIZED EQUIPMENT 4. ALL AVAILABLE JURISDICTIONAL PERMIT AND OCCUPANCY INFORMATION 5. PDF SCAN OF REDLINES PRODUCED IN FIELD 6. A PDF SCAN OF REDLINE MARK-UPS SUITABLE FOR USE IN ELECTRONIC AS -BUILT DRAWING PRODUCTION 7. LIEN WAIVERS 8. FINAL PAYMENT APPLICATION 9. REQUIRED FINAL CONSTRUCTION PHOTOS 10. CONSTRUCTION AND COMMISSIONING CHECKLIST COMPLETE WITH NO DEFICIENT ITEMS 11. APPLICABLE POST NTP TASKS INCLUDING DOCUMENT UPLOADS COMPLETED IN SITERRA (SPRINTS DOCUMENT REPOSITORY OF RECORD). 12. CLOSEOUT PHOTOGRAPHS AND CLOSEOUT CHECKLIST: SPRINT WILL PROVIDE SEPARATE GUIDANCE SECTION 11 700 - ANTENNA ASSEMBLY, REMOTE RADIO UNITS AND CABLE INSTALLATION SUMMARY: THIS SECTION SPECIFIES INSTALLATION OF ANTENNAS, RRH'S, AND CABLE EQUIPMENT, INSTALLATION, AND TESTING OF COAXIAL FIBER CABLE. ANTENNAS AND RRH'S: THE NUMBER AND TYPE OF ANTENNAS AND RRH'S TO BE INSTALLED IS DETAILED ON THE CONSTRUCTION DRAWINGS. HYBRID CABLE: HYBRID CABLE WILL BE DC/FIBER AND FURNISHED FOR INSTALLATION AT EACH SITE. CABLE SHALL BE INSTALLED PER THE CONSTRUCTION DRAWINGS AND THE APPLICABLE MANUFACTURER'S REQUIREMENTS. JUMPERS AND CONNECTORS, FURNISH AND INSTALL 1/2" COAX JUMPER CABLES BETWEEN THE RRH'S AND ANTENNAS. JUMPERS SHALL BE TYPE LDF 4, FLC 12-50, CR 540, OR FXL 540. SUPER -FLEX CABLES ARE NOT ACCEPTABLE JUMPERS BETWEEN THE RRH'S AND ANTENNAS OR TOWER TOP AMPLIFIERS SHALL CONSIST OF 1/2 INCH FOAM DIELECTRIC, OUTDOOR RATED COAXIAL CABLE, MIN LENGTH FOR JUMPER SHALL BE 10"-0". REMOTE ELECTRICAL TILT (RET) CABLES: MISCELLANEOUS: INSTALL SPUTTERS, COMBINERS, FILTERS PER RF DATA SHEET, FURNISHED BY SPRINT. ANTENNA INSTALLATION, THE CONTRACTOR SHALL ASSEMBLE ALL ANTENNAS ONSITE IN ACCORDANCE WITH THE INSTRUCTIONS SUPPLIED BY THE MANUFACTURER. ANTENNA HEIGHT, AZIMUTH, AND FEED ORIENTATION INFORMATION SHALL BE A DESIGNATED ON THE CONSTRUCTION DRAWINGS. A. THE CONTRACTOR SHALL POSITION THE ANTENNA ON TOWER PIPE MOUNTS SO THAT THE BOTTOM STRUT IS LEVEL THE PIPE MOUNTS SHALL BE PLUMB TO WITHIN 1 DEGREE. B. ANTENNA MOUNTING REQUIREMENTS: PROVIDE ANTENNA MOUNTING HARDWARE AS INDICATED ON THE DRAWINGS. HYBRID CABLE INSTALLATION: A THE CONTRACTOR SHALL ROUTE, TEST, AND INSTALL ALL CABLES AS INDICATED ON THE CONSTRUCTION DRAWINGS AND IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. B. THE INSTALLED RADIUS OF THE CABLES SHALL NOT BE LESS THAN THE MANUFACTURER'S SPECIFICATIONS FOR BENDING RADII. C. EXTREME CARE SHALL BE TAKEN TO AVOID DAMAGE TO THE CABLES DURING HANDLING AND INSTALLATION. 1. FASTENING MAIN HYBRID CABLES: ALL CABLES SHALL BE INSTALLED INSIDE MONOPOLE WITH CABLE SUPPORT GRIPS AS REQUIRED BY THE MANUFACTURER. 2. FASTENING INDIVIDUAL FIBER AND DC CABLES ABOVE BREAKOUT ENCLOSURE (MEDUSA), WITHIN THE MMBS CABINET AND ANY INTERMEDIATE DISTRIBUTION BOXES: a. FIBER: SUPPORT FIBER BUNDLES USING %' VELCRO STRAPS OF THE REQUIRED LENGTH 0 18' OC. STRAPS SHALL BE UV, OIL AND WATER RESISTANT AND SUITABLE FOR INDUSTRIAL INSTALLATIONS AS MANUFACTURED BY TEXTOL OR APPROVED EQUAL b. DC: SUPPORT DC BUNDLES WITH ZIP TIES OF THE ADEQUATE LENGTH. ZIP TIES TO BE UV STABILIZED, BLACK NYLON, WITH TENSILE STRENGTH AT 12.000 PSI AS MANUFACTURED BY NELCO PRODUCTS OR EQUAL 3. FASTENING JUMPERS: SECURE JUMPERS TO THE SIDE ARMS OR HEAD FRAMES USING STAINLESS STEEL TIE WRAPS OR STAINLESS STEEL BUTTERFLY CLIPS. 4. CABLE INSTALLATION: a. INSPECT CABLE PRIOR TO USE FOR SHIPPING DAMAGE, NOTIFY THE CONSTRUCTION MANAGER. b. CABLE ROUTING: CABLE INSTALLATION SHALL BE PLANNED TO ENSURE THAT THE LINES WILL BE PROPERLY ROUTED IN THE CABLE ENVELOP AS INDICATED ON THE DRAWINGS. AVOID TWISTING AND CROSSOVERS. c. HOIST CABLE USING PROPER HOISTING GRIPS. DO NOT EXCEED MANUFACTURES RECOMMENDED MAXIMUM BEND RADIUS. 5. GROUNDING OF TRANSMISSION LINES: ALL TRANSMISSION LINES SHALL BE GROUNDED AS INDICATED ON DRAWINGS. 6. HYBRID CABLE COLOR CODING: ALL COLOR CODING SHALL BE AS REQUIRED IN TS 0200 REV 4. 7. HYBRID CABLE LABELING: INDIVIDUAL HYBRID AND DC BUNDLES SHALL BE LABELED ALPHA -NUMERICALLY ACCORDING TO SPRINT CELL SITE ENGINEERING NOTICE - EN 2012-001, REV 1 WEATHERPROOFING EXTERIOR CONNECTORS AND HYBRID CABLE GROUND KITS: A. ALL FIBER & COAX CONNECTORS AND GROUND KITS SHALL BE WEATHERPROOFED. B. WEATHERPROOFED USING ONE OF THE FOLLOWING METHODS. ALL INSTALLATIONS MUST BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND INDUSTRY BEST PRACTICES. 1. COLD SHRINK: ENCOMPASS CONNECTOR IN COLD SHRINK TUBING AND PROVIDE A DOUBLE WRAP OF 2' ELECTRICAL TAPE EXTENDING 2' BEYOND TUBING. PROVIDE 3M COLD SHRINK CXS SERIES OR EQUAL 2.1 SELF -AMALGAMATING TAPE: CLEAN SURFACES. APPLY A DOUBLE WRAP OF SELF -AMALGAMATING TAPE 2' BEYOND CONNECTOR. APPLY A SECOND WRAP OF SELF -AMALGAMATING TAPE IN OPPOSITE DIRECTION. APPLY DOUBLE WRAP OF 2' WIDE ELECTRICAL TAPE EXTENDING 2' BEYOND THE SELF -AMALGAMATING TAPE 3. 3M SLIM LOCK CLOSURE 716: SUBSTITUTIONS WILL NOT BE ALLOWED. 4. OPEN FLAME ON JOB SITE IS NOT ACCEPTABLE SECTION 11 800 - INSTALLATION OF MULTIMODAL BASE STATIONS (MMBS) AND RELATED EQUIPMENT A THIS SECTION SPECIFIES MMBS CABINETS, POWER CABINETS. AND INTERNAL EQUIPMENT INCLUDING BY NOT LIMITED TO RECTIFIERS, POWER DISTRIBUTION UNITS. BASE BAND UNITS, SURGE ARRESTORS, BATTERIES, AND SIMILAR EQUIPMENT FURNISHED BY THE COMPANY FOR INSTALLATION BY THE CONTRACTOR (OFCI). B. CONTRACTOR SHALL PROVIDE AND INSTALL ALL MISCELLANEOUS MATERIALS AND PROVIDE ALL LABOR REQUIRED FOR INSTALLATION EQUIPMENT IN EXISTING CABINET OR INSTALLATION CABINS As SHOWN ON DRAWINGS AND AS REQUIRE BY THE APPLICABLE s. C. COMPLY WITH MANUFACTURERS INSTALLATION AND START-UP REQUIREMENTS kNS PREPARED FOR Sprint` )Pr Together with Nextei. smart i k 8502 E VIA DE VENTURA, SUITE 220 SCOTTSDALE, AZ 85258 xx FIELD SERVICES I>t here quality still counts. 2227 W PECOS RD. SUITE 4 CHANDLER, AZ 85224 o uor+Ev A 09/26/17 907.' CD'S APR B 09/27/17 CLIENT COMMENTS APR C 10/18/17 SOW CHANGES CW 0 11/28/17 SUBMITTAL CD's CW 01 01/09/18 JX COMMENTS I CW CROWN ORO VALLEY PH63XC506-A 55 E. TANGERINE RD ORO VALLEY, AZ 85737 SPRINT SPECIFICATIONS SP- I SECTION 26 100 - BASIC ELECTRICAL REQUIREMENTS SUMMARY, THIS SECTION SPECIFIES BASIC ELECTRICAL REQUIREMENTS FOR SYSTEMS AND COMPONENTS. QUALITY ASSURANCE: A ALL EQUIPMENT FURNISHED UNDER DIVISION 26 SHALL CARRY UL LABELS AND LISTINGS WHERE SUCH LABELS AND LISTINGS ARE AVAILABLE IN THE INDUSTRY. B. MANUFACTURERS OF EQUIPMENT SHALL HAVE A MINIMUM OF THREE YEARS EXPERIENCE WITH THEIR EQUIPMENT INSTALLED AND OPERATING IN THE FIELD IN A USE SIMILAR TO THE PROPOSED USE FOR THIS PROJECT. C. IPME : ALL MATERIALS AND EQUIPMENT SPECIFIED IN DIVISION 26 OF THE S E TYPE SHALL BE OF THE SAME MANUFACTURER AND SHALL BE NEW, OF THE BEST QUALITY AND DESIGN, AND FREE FROM DEFECTS SUPPORTING DEVICES: A. ALL EQUIPMENT FURNISHED UNDER DIVISION 26 SHALL CARRY UL LABELS AND LISTINGS WHERE SUCH LABELS AND LISTINGS ARE AVAILABLE IN THE INDUSTRY. B. MANUFACTURERS OF EQUIPMENT SHALL HAVE A MINIMUM OF THREE YEARS EXPERIENCE WITH THEIR EQUIPMENT INSTALLED AND OPERATING IN THE FIELD IN A USE SIMILAR TO THE PROPOSED USE FOR THIS PROJECT, C. ALL MATERIALS AND EQUIP ENT SPECIFIED IN DIVISION 26 OF THE SAME TYPE SHALL BE OF THE SAME MANUFACTURER AND SHALL BE NEW, OF THE BEST QUALITY AND DESIGN, AND FREE FROM DEFECTS SUPPORTING DEVICES: A MANUFACTURED STRUCTURAL SUPPORT MATERIALS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY THE FOLLOWING: 1. ALLIED TUBE AND CONDUIT 2. B-LINE SYSTEM 3. UNISTRUT DIVERSIFIED PRODUCTS 4. THOMAS & BETTS B. FASTENERS: TYPES, MATERIALS, AND CONSTRUCTION FEATURES AS FOLLOWS: 1. EXPANSION ANCHORS: CARBON STEEL WEDGE OR SLEEVE TYPE- 2. POWER -DRIVEN THREADED STUDS: HEAT -TREATED STEEL, DESIGNED SPECIFICALLY FOR THE INTENDED SERVICE- 3. FASTEN BY MEANS OF WOOD SCREWS ON WOOD. 4. TOGGLE BOLTS ON HOLLOW MASONRY UNITS. 5. CONCRETE INSERTS OR EXPANSION BOLTS ON CONCRETE OR SOLID MASONRY. 6. MACHINE SCREWS, WELDED THREADED STUDS, OR SPRING -TENSION CLAMPS ON STEEL 7. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE SHALL NOT BE PERMITTED. 8. DO NOT WELD CONDUIT, PIPE STRAPS, OR ITEMS OTHER THAN THREADED STUDS TO STEEL STRUCTURES. 9. IN PARTITIONS OF LIGHT STEEL CONSTRUCTION, USE SHEET METAL SCREWS. SUPPORTING DEVICES: A. INSTALL SUPPORTING DEVICES TO FASTEN ELECTRICAL COMPONENTS SECURELY AND PERMANENTLY IN ACCORDANCE WITH NEC. B. COORDINATE WITH THE BUILDING STRUCTURAL SYSTEM AND WITH OTHER TRADES. C. UNLESS OTHERWISE INDICATED ON THE DRAWINGS, FASTEN ELECTRICAL ITEMS AND THEIR SUPPORTING HARDWARE SECURELY TO THE STRUCTURE IN ACCORDANCE WITH THE FOLLOWING: D. ENSURE THAT THE LOAD APPLIED BY ANY FASTENER DOES NOT EXCEED 25 PERCENT OF THE PROOF TEST LOAD. E. USE VIBRATION AND SHOCK -RESISTANT FASTENERS FOR ATTACHMENTS TO CONCRETE SLABS. ELECTRICAL IDENTIFICATION: A UPDATE AND PROVIDE TYPED CIRCUIT BREAKER SCHEDULES IN THE MOUNTING BRACKET, INSIDE DOORS OF AC PANEL BOARDS WITH ANY CHANGES MADE TO THE AC SYSTEM. B. BRANCH CIRCUITS FEEDING AVIATION OBSTRUCTION LIGHTING EQUIPMENT SHALL BE CLEARLY IDENTIFIED AS SUCH AT THE BRANCH CIRCUIT PANELBOARD. SECTION 26 20Q - ELECTRICAL MATERIALS AND EQUIPMENT CONDUIT: A RIGID GALVANIZED STEEL (RGS) CONDUIT SHALL BE USED FOR EXTERIOR LOCATIONS ABOVE GROUND AND IN UNFINISHED INTERIOR LOCATIONS AND FOR ENCASED RUNS IN CONCRETE RIGID CONDUIT AND FITTINGS SHALL BE STEEL, COATED WITH ZINC EXTERIOR AND INTERIOR BY THE HOT DIP GALVANIZING PROCESS. CONDUIT SHALL BE PRODUCED TO ANSI SPECIFICATIONS C80.1, FEDERAL SPECIFICATION WW-C-581 AND SHALL BE LISTED WITH THE UNDERWRITERS' LABORATORIES. FITTINGS SHALL BE THREADED - SET SCREW OR COMPRESSION FITTINGS WILL NOT BE ACCEPTABLE. RGS CONDUITS SHALL BE MANUFACTURED BY ALLIED, REPUBLIC OR WHEATLAND. B. UNDERGROUND CONDUIT IN CONCRETE SHALL BE POLYVINYLCHLORIDE (PVC) SUITABLE FOR DIRECT BURIAL AS APPLICABLE. JOINTS SHALL BE BELLED, AND FLUSH SOLVENT WELDED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. CONDUIT SHALL BE CARLON ELECTRICAL PRODUCTS OR APPROVED EQUAL C. TRANSITIONS BETWEEN PVC AND RIGID (RGS) SHALL BE MADE WITH PVC COATED METALLIC LONG SWEEP RADIUS ELBOWS. D. EMT OR RIGID GALVANIZED STEEL CONDUIT MAY BE USED IN FINISHED SPACES CONCEALED IN WALLS AND CEILINGS. EMT SHALL BE MILD STEEL. ELECTRICALLY WELDED, ELECTRO-GALVANIZED OR HOT -DIPPED GALVANIZED AND PRODUCED TO ANSI SPECIFICATION C80.3, FEDERAL SPECIFICATION WW-C-563, AND SHALL BE UL LISTED. EMT SHALL BE MANUFACTURED BY AWED, REPUBLIC OR WHEATLAND, OR APPROVED EQUAL FITTINGS SHALL BE METALLIC COMPRESSION. SET SCREW CONNECTIONS SHALL NOT BE ACCEPTABLE. E. LIQUID TIGHT FLEXIBLE METAWC CONDUIT SHALL BE USED FOR FINAL CONNECTION TO EQUIPMENT. FITTINGS SHALL BE METALLIC GLAND TYPE COMPRESSION FITTINGS, MAINTAINING THE INTEGRITY OF CONDUIT SYSTEM. SET SCREW CONNECTIONS SHALL NOT BE ACCEPTABLE. MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL NOT EXCEED 6-FEET. LFMC SHALL BE PROTECTED AND SUPPORTED AS REQUIRE BY NEC. MANUFACTURERS OF FLEXIBLE CONDUITS SHALL BE CAROL, ANACONDA METAL HOSE OR UNIVERSAL METAL HOSE, OR APPROVED EQUAL F. MINIMUM SIZE CONDUIT SHALL BE 3/4 INCH (21MM). HUBS AND BOXES: A. AT ENTRANCES TO CABINETS OR OTHER EQUIPMENT NOT HAVING INTEGRAL THREADED HUBS PROVIDE METALLIC THREADED HUBS OF THE SIZE AND CONFIGURATION REQUIRED. HUB SHALL INCLUDE LOCKNUT AND NEOPRENE 0-RING SEAL PROVIDE IMPACT RESISTANT 105 DEGREE C PLASTIC BUSHINGS TO PROTECT CABLE INSULATION. B. CABLE TERMINATION FITTINGS FOR CONDUIT 1. CABLE TERMINATORS FOR RGS CONDUITS SHALL BE TYPE CRC BY O-Z/GEDNEY OR EQUAL BY ROX TEC. 2. CABLE TERMINATORS FOR LFMC SHALL BE ETCO - CL2075; OR MADE FOR THE PURPOSE PRODUCTS BY ROXTEC. C. EXTERIOR PULL BOXES AND PULL BOXES IN INTERIOR INDUSTRIAL AREAS SHALL BE PLATED CAST ALLOY, HEAVY DUTY, WEATHERPROOF, DUST PROOF, WITH GASKET, PLATED IRON ALLOY COVER AND STAINLESS STEEL COVER SCREWS, CROUSE-HINDS WAB SERIES OR EQUAL D. CONDUIT OUTLET BODIES SHALL BE PLATED CAST ALLOY WITH SIMILAR GASKETED COVERS. OUTLET BODIES SHALL BE OF THE CONFIGURATION AND SIZE SUITABLE FOR THE APPLICATION. PROVIDE CROUSE-HINDS FORM 8 OR EQUAL E. MANUFACTURER FOR BOXES AND COVERS SHALL BE HOFFMAN, SQUARE "D", CROUSE-HINDS, COOPER, ADALEI, APPLETON, O-Z GEDNEY, RACO, OR APPROVED EQUAL SUPPLEMENTAL GROUNDING SYSTEM A FURNISH AND INSTALL A SUPPLEMENTAL GROUNDING SYSTEM TO THE EXTENT INDICATED ON THE DRAWINGS. SUPPORT SYSTEM WITH NON-MAGNETIC STAINLESS STEEL CLIPS S SIZES RUBBER AS INDICATED GROMMETS. GROUNDING DRAWINGS. CO ROVIDERSTRAN STRANDED OR TINNED BAREEORWIRE, INSULATED CONDUCTORS EXCEPTED AS OTHERWISE NOTED. B. SUPPLEMENTAL GROUNDING SYSTEM: ALL CONNECTIONS TO BE MADE WITH CAD WELDS, EXCEPT AT EQUIPMENT USE LUGS OR OTHER AVAILABLE GROUNDING MEANS AS REQUIRED BY MANUFACTURER; AT GROUND BARS USE TWO HOLE SPADES WITH NO OX. C. STOLEN GROUND -BARS: IN THE EVENT OF STOLEN GROUND BARS, CONTACT SPRINT CM FOR REPLACEMENT INSTRUCTION USING THREADED ROD KITS. EXISTING STRUCTURE: A EXISTING EXPOSED WIRING AND ALL EXPOSED OUTLETS, RECEPTACLES, SWITCHES, DEVICES, BOXES, AND OTHER EQUIP ENT THAT ARE NOT TO BE UTIUZED IN THE COMPLETED PROJECT SHALL BE REMOVED OR DE -ENERGIZED AND CAPPED IN THE WALL, CEILING, OR FLOOR SO THAT THEY ARE CONCEALED AND SAFE. WALL, CEILING, OR FLOOR SHALL BE PATCHED TO MATCH THE ADJACENT CONSTRUCTION. CONDUIT AND CONDUCTOR INSTALLATION: A. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE WILL SE PROXIMITY MO THE STR CLTURE ANFOLLOD EEPTHELLCONDUITSNES OFnIN GHTCTUREENVELOPEIS. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE B. CONDUCTORS SHALL BE PULLED IN ACCORDANCE WITH ACCEPTED GOOD PRACTICE. ENGINEERS NOTES 1. IF A DISCREPANCY ARISES BETWEEN THE DRAWINGS AND FIELD CONDITIONS, OR WHERE A DETAIL IS Sprint')? DOUBTFUL OF INTERPRETATION, OR AN UNANTICIPATED FIELD CONDITION IS ENCOUNTERED, THE ENGINEER SHALL BE CALLED IMMEDIATELY FOR PROCEDURE TO BE FOLLOWED. SUCH INSTRUCTIONS SHALL BE CONFIRMED IN WRITING AND DISTRIBUTED TO ALL AFFECTED PARTIES. 2. THE ENGINEER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES. Together with Nextel. SEQUENCES, PROCEDURES, SAFETY PRECAUTIONS, OR PROGRAMS UTILIZED IN CONNECTION WITH THE WORK, AND WILL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S FAILURE TO CARRY OUT THE WORK IN ACCORDANC CONSULTANT WITH THE CONSTRUCTION DRAWING AND/OR DOCUMENTS. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER LAYOUT OF IMPROVEMENTS BASED UPON SETBACKS/ PROPERTY LINE LOCATION. DIMENSIONAL RELATIONSHIPS TO EQUIPMENT ARE APPROXIMATE AND ARE FOR 0 smart ILLUSTRATIVE PURPOSES ONLY. 4. CONTRACTOR TO MAINTAIN ALL DRAINAGE PATHS FREE FROM ANY OBSTRUCTIONS (I.E. DEBRIS AND SILT). 8502 E VIA DE VENTURA, SUITE 220 5. CONTRACTOR TO PROVIDE POSITIVE DRAINAGE AWAY FROM EQUIPMENT. SCOTTSDALE, AZ 85258 6. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE ENGINEER OF RECORD SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CONTRACTOR AND ENGINEER OF RECORD. 7. SUBCONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES, GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWING. SUBCONTRACTOR SHALL UTILIZE EXISTING TRAYS AND/OR SHALL ADD NEW TRAYS AS NECESSARY. SUBCONTRACTOR SHALL CONFIRM THE ACTUAL ROUTING WITH THE CONTRACTOR. ROUTING OF TRENCHING SHALL BE APPROVED BY CONTRACTOR FIELD SERVICES UTILITY NOTES here quality still counts. 1. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO CONTACT BLUESTAKE AT LUST TWO FULL WORKING 2227 PECOS RD, SUITE 4 DAYS (48 HOURS) PRIOR TO BEGINNING OF ANY EXCAVATING. CHAA NDLER, AZ 85224 2. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO LOCATE ALL STRUCTURES, UNDERGROUND PIPELINES. ELECTRIC AND TELEPHONE CONDUITS, EITHER SHOWN OR NOT SHOWN ON THE PLANS PRIOR TO ANY CONSTRUCTION, AND TO OBSERVE ALL POSSIBLE PRECAUTIONS TO AVOID ANY DAMAGE TO THESE FACILITIES. THE ENGINEERING AND/OR DEVELOPER WILL NOT GUARANTEE ANY ELEVATIONS OR LOCATIONS OF EXISTING 1 UNDERGROUND UTILITIES SHOWN ON THESE PLANS. 1 3. CONTRACTOR TO VERIFY LOCATION AND ELEVATION OF ALL UTILITY CONNECTIONS./ .., e-� CONSTRUCTION NOTES: AISG TESTS TO VERIFY OPERATION IS TO BE PERFORMED AFTER FINAL INSTALLATION OF ANTENNAS AND AISG c MONEY CABLES HAVE BEEN CONNECTED. VERFY OPERATION OF ALL EXISTING SPRINT AISG EQUIPMENT INCLUDING 800MHZ. 1.9GHZ AND 2.5GHZ. TEST INCLUDE COMPLETE DOWNTILT, AZIMUTH (IF APPLICABLE) AND 13EAMWIDTH SWINGS (IF APPLICABLE). DOCUMENT AISG TEST RESULTS IN COAX SWEEP TEST SPREADSHEET. F+Arcs�zn�iti° 1) GENERAL CONTRACTOR MUST INSURE THAT NO OBJECT IS LOCATED IN FRONT OF ANTENNA THIS MEANS NO OBJECT IS TO BE LOCATED 45 DEGREES LEFT AND RIGHT OF FRONT OF ANTENNA OR 67.5 DEGRESS FROM HORIZONTAL FROM TOP AND BOTTOM OF ANTENNA IF THIS IS NOT POSSIBLE. CONTACT RF ENGINEER FOR FURTHER INSTRUCTION. IN ADDITION, 2.6GHZ ANTENNA IS NOT TO BE PLACED IN FRONT OF ANY OTHER ANTENNA USING THE SAME RULES AS ABOVE. THIS INCLUDES SPRINT AND NON -SPRINT ANTENNAS• NO. DATE DESCRIPTION BY- 2) GENERAL CONTRACT IS REQUIRED TO USE A DIGITAL ALIGNMENT TOOL TO SET AZIMUTH. ROLL AND A 09/26/17 907' CD'S JAPR DOWNTILT. AZIMUTH ACCURACY IS TO BE WITHIN 3 DEGREES. DOWNTILT AND ROLL (LEFT TO RIGHT TILT) IS TO BE WITHIN 0.1 DEGREES. IF FOR SOME REASON THIS ACCURACY CANNOT BE ACHIEVED, UPDATE AS -BUILT DRAWINGS AND EMAIL SPRINT RF ENGINEER WITH AS -BUILT SETTINGS. USE 3Z RF ALIGNMENT TOOL OR B 09/27/17 CLIENT COMMENTS APR EQUIVALENT TOOL HTTP://W".3ZTELECOM.COM/ANTENNA-AUGNMENT-TOOL/ C 10/18/17 SOW CHANGES I CW 0 11/28/17 SUBMITTAL CD'S CW ]cW Al 01/09/18 JX COMMENTS PROJECT CROWN ORO VALLEY PH63XC506-A 55 E. TANGERINE RD ORO VALLEY, AZ 85737 SPRINT SPECIFICATIONS, ENGINEERS AND UTILITY NOTES O I • 1 SEE ANTENNA PLAN 3/4 I I A-3 SPRINT HANDHOLE N TANGRINE RD J NOTES: NO SURVEY HAS BEEN PERFORMED ON THIS SITE. ALL PARCEL/PROPERTY LINES SHOWN ARE APPROXIMATE LOCATIONS. ITEMS NOT DIMENSIONED ARE FOR GRAPHICAL REPRESENTATION ONLY Know •hd'. "aW. Owl bean you dip 1-800-424-5555 60' _ 30' 0 _ 30' 60, NORTH HA�L�F SCIMr ALE 1" = 60' Sprint _ Together with Nextel. @smart1hrd,'-- 8502 E VIA DE VENTURA. SUITE 220 SCOTTSDALE, AZ 85258 xx FIELD SERVICES \\ here quality still counts. 2227 W PECOS RD, SURE 4 CHANDLER, AZ 85224 10M u MAM _ MONEV 09. / P yes 171.1All A 09/26/17 90% CD'S APR B 09/27/17 CLIENT COMMENTS APR C 10/18/17 SOW CHANGES CW 0 11/28/17 SUBMITTAL CD'S CW ,& 01/09/18 JX COMMENTS CW CROWN ORO VALLEY PH63XC506-A 65 E. TANGERINE RD ORO VALLEY, AZ 85737 OVERALL SITE PLAN 4-1 OVERALL SITE PLAN NOTES: EXISTING 1900 RRH UNITS AT GRADE AND NOT SHOWN FOR CLARITY TO BE RELOCATED TO NEW MOUNT " �1M�ZN 250 EXISTING ANTENNA PLAN w NEW SPRINT ANTENNAS (3) PER SECTOR, (9) TOTAL a AT EXISTING ANTENNA RAD CENTER. GROUND �G ANTENNA PIPE TO EXISTING GROUND BAR (TYP.); A -POS.1 EXISTING 1900 ANTENNA -POS.2 NEW RFS# APXVTMI4-ALU-120 -POS.3 NEW RFS# APX9ERR18 1 SPRINT RRH (4) PER SECTOR, (12) TOTAL MOUNTED V BEHIND ANTENNAS. GROUND RRH TO EXISTING \ GROUND BAR; -POSH EXISTING 1900 RRH NEW ALU# 80OMHZ -POS.2 NEW ALU# TO-RRHSX20-25 -POS.3 NEW ALU# 80OMHZ 4/5 2 A-5 PyM��N Z50 A NEW 37' CABLE SHROUD MOUNTED - TO SIDE OF EXISTING TRANSMISSION TOWER PAINTED TO MATCH EXISTING FINAL ANTENNA PLAN EXISTING SPRINT ANTENNAS IN POSH (1) PER SECTOR, (3) TOTAL TO BE RELOCATED TO NEW MOUNT; -ALPHA EXISTING 1900 ANTENNA (RFS# APX9ERR18) -BETA EXISTING 1900 ANTENNA (RFS# APX9ERR18) -GAMMA EXISTING 1900 ANTENNA (KMW# ET-X-TU-42-15-37-18-IR-RA) 770• A2GyLrN 2 EW NEWAVE MONOPOLE T—ARM FRAME IMTF3-18825 W/ STIFF ARM #AM1031 1) PER SECTOR, (3) TOTAL PAINT ALL NEW ANTENNAS AND APPURTENANCES TO MATCH EXISTING SITE CONDITIONS, PER LOCAL JURISDICTION REQUIREMENTS FULL SCALE 1" = 1'-0" aax s aa» 2' V 0 1' 2' NORTH HALF SCALE 1/2" = 1'-0" (,,.17 a aa» ITEMS NOT DIMENSIONED ARE FOR GRAPHICAL REPRESENTATION ONLY EXISTING ANTENNAS REMOVED FOR CLARITY EXISTING METERS T— EXISTING TELCO BOX EXISTING CENTURYLI* TELCO BO) 3 I EXISTING EQUIPMENT PLAN 3_ 1 EXISTING METER A2iM�TH 78• 1 EXISTING TELCO BOX 0 i 2 N EXISTING CENTURYLINK TELCO BOX VL NEW (1) 2" METAL CONDUIT & LIQUID TIGHT 3/4 FLEXIBLE METALLIC A-8 CONDUIT WITH (3) #1 AWG AND (1) #6 AWG GROUND FROM NEW 80/2 BREAKER FROM PPC TO NEW 9927 MMBTS FULL SCALE 1" - 1,-O. (2-4 2' 1' 0 1' 2' NORTH HALF SCALE 1/2" = 1'-0" (n.n —T aw» 4 I FINAL EQUIPMENT PLAN EXISTING DISCONNECT EXISTING PPC CABINET W/ GEN PLUG --EXISTING FIBER DISTRIBUTION BOX �I EXISTING MOD-CEL TO BE REPLACED I EXISTING COAX SUPPORT FRAME I I EXISTING CPS ANTENNA (TYP. OF 2) EXISTING BATTERY CABINET (BBU) TO BE REPLACED EXISTING CIENA Ix I I EXISTING DISCONNECT EXISTING PPC CABINET W/ GEN PLUG I 1 1 1� 1 I 1 I_ 1 1 1 00 FOUL �C�n 3/8" = 1'-0" 4' 2' 0 V 2' V 6' NORTH HALF SCALE _ 3/16" = 1'-0" (n.n — 00M 1 NEW (1) 1 e BATTERY CABINET, A-8 FILL TO CAPACITY NEW (1) 992E ej MMBTS CABINET A-8 W/ 2.5 CARD EXISTING FIBER DISTRIBUTION BOX — ANEW (1) 2" METAL CONDUIT & LIQUID TIGHT FLEXIBLE METALLIC CONDUIT WITH (9) FIBER OPTIC CABLE FROM NEW 9927 MMBTS TO EXISTING NV DISTRIBUTION BOX 3/4 jI� A-8 NEW (1) 2" METAL CONDUIT & LIQUID TIGHT FLEXIBLE METALLIC CONDUIT WITH (2) #2 AWG AND (1) #6 AWG GROUND FROM DISTRIBUTION CABINET TO 9927 MMBTS 3/4 I A-8 —EXISTING CPS ANTENNA (TYP. OF 2) EXISTING CIENA 4/12�(�m�u ' ALE 3/8" = 1'-0" 4' 2' 0 t' 2' 3 8' NORTH HALF SCALE 3/16" = V-0" 2 4N5 HKtrAKtU tUK Sprint° )?� Together with Nextel. smart rik, 8502 E VIA DE VENTURA, SUITE 220 SCOTTSDALE, AZ 85258 -ENGINEER OF RECORD xx FIELD SERVICES 11 here quality still counts. 2227 W PECOS RD, SUITE 4 CHANDLER, AZ 85224 A 09/26/17 909 CD'S APR B 09/27/17 CLIENT COMMENTS APR C 10/18/17 SOW CHANGES CW 0 11/28/17 SUBMITTAL CD'S CW Qt 01/09/18 JX COMMENTS CW CROWN ORO VALLEY PH63XC506-A 55 E. TANGERINE RD ORO VALLEY, AZ 85737 EXISTING/FINAL EQUIPMENT AND ANTENNA PLAN SHEET A-3 EXISTING SPRINT ANTENNAS IN POSH (1) PER SECTOR, (3) TOTAL TO BE RELOCATED TO NEW MOUNT; -ALPHA EXISTING 1900 ANTENNA (RFS# APX9ERR18) -BETA EXISTING 1900 ANTENNA (RFS# APX9ERR18) -GAMMA EXISTING 1900 ANTENNA (KMW# ET-X-TU-42-15-37-18-IR-RA) NOTES: STRUCTURAL ANALYSIS MUST BE PERFORMED ON ALL POLES, TOWERS & ROOFTOPS BEFORE INSTALLATION OF ANY NEW ANTENNAS AND/OR RRH'S. STRUCTURAL ANALYSIS PROVIDED BY TEP DATED 10/18/17 MOUNT ANALYSIS PROVIDED BY ISE INC DATED 11/18/17 ANTENNA CLEARANCE AND MOUNTING TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION WITH FINAL ANTENNA SPECIFICATIONS, MOUNTING HARDWARE, AND RF DESIGN. ANTENNA PIPE MOUNT MODIFICATION MAY BE REQUIRED. PAINT AL:NEW ANTENNAS5 IAPPURTENANCES, ANDTRANSMISN TOWER TO MATCH EXISTING SITECONDITIOPER LOCAL JURISDICTION REQUIREMENTS CONTRACTOR TO TAKE SPECIAL CARE WHEN INSTALLING NEW MOUNT AND TOWER EQUIPMENT TO STAY CLEAR OF EXISTING ELECTRICAL LINES kNS PREPARED FOR Sp ri nt° )019 Together with Nextel. smartlin 8502 E VIA DE VENTURA, SUITE 220 SCOTTSDALE. AZ 85258 FIELD SERVICES - _ - _ - — Alk here quality still counts. EXISTING STATIC WIRE 2227 W PECOS RD, SUITE 4 CHANDLER, AZ 85224 SPRINT RRH (4) PER SECTOR, (12) TOTAL MOUNTED BEHIND ANTENNAS. GROUND RRH TO EXISTING GROUND BAR; I -POSH EXISTING 1900 RRH NEW ALU# 80OMHZ / I -POS.2 NEW ALU# TD-RRH8X20-25 -POS.3 NEW ALU# 80OMHZ 4/5 A-5 EXISTING STATIC WIRE r •�°w r�" 11 I I of I 0 Li 1/2 NEW NEWAVE MONOPOLE T-ARM FRAME 1 q"e cxE° P w < A-8 #MTF3-18825 W/ STIFF ARM #AM1031 EP.1sn+ti° V) I (1) PER SECTOR, (3) TOTAL Cn of m tn of z 3 d1 I EXISTING LINE CONFIG: z 3 < (4) NEW 1-1/4" HYBRIFLEX CABLE w ¢ < I (9) 7/8" COAX CABLES w of z 0. DATE — ATE DESCRIPTION BY z I (1) NEW 5/8" FIBER LINE ~ a_ I TO BE REMOVED w I z< z z o_ I z z � NEW SPRINT ANTENNAS (3) PER SECTOR, (9) FINAL LINE CONFlG: A 09/26/17 907." CD'S APF 0 - < < 0 zz TOTAL AT EXISTING ANTENNA RAD CENTER. GROUND I (4) 1-1/4" HYBRIFLEX CABLE z N �¢ z I z ANTENNA PIPE TO EXISTING GROUND BAR (TYP.); I (1) 5/8" FIBER LINE B 09/27/17 CLIENT COMMENTS APF of f z - I ZE -m z -POSA EXISTING 1900 ANTENNA vv) 2: w < I N z 0- -POS.2 NEW RFS# APXVTMI4-ALU-120 I z Ir z w j 0 o N -POS.3 NEW RFS# APX9ERR18 1 C 10/18/17 SOW CHANGES CW z r 0 I NEW 37' CABLE SHROUD MOUNTED / / 0 r z I 0 z T 2 2 0 11 28 17 SUBMITTAL CO'S CW w Ln 0- ¢ w N En Z X A-5 A-8 TOWER TO EOF PAINTEDI TO MATCHSMISSION EXISTING 01 01 /09/1 B JX COMMENTS CW 0 w of j wo w L- a- Ld TRANSMISSION TOWER L. z V) o w 0 0 U) 0 I 0 0 0: o 52 z a PROJECT INFORMATION I w I o z w N I o F w Co 0 0 w I 0 a U W 0 I M zUj of I I L) U I EXISTING RRH'S TO BE 0 w RELOCATED (1) PER M I O^I O 0 O 0 EXISTING CMU BLOCK SECTOR, (3) TOTAL EXISTING CMU BLOCK I CROWN v COMPOUND WALL I COMPOUND WALL M o<fo i VALLEY PH63XC506—A 55 E. TANGERINE RD - - - - - - _ ORO VALLEY. AZ 85737 ❑0 - - - - _ �p SHEET TITLE EXISTING/FINAL ELEVATION EXISTING EAST ELEVATION psi SCAL 3/8" = 1'-0" 4' 2' 0 1' 2' 3' 6' HALF SCALE 3/16" = 1'-0" (11.11 s uah 2 1 FINAL EAST ELEVATION FULL SCALE 1 /8" = 1'-0" 0 6' 16' HALF SCALE 1/16" = 1'-0" t11.17 a a" A-4 Town of Oro Valley Development and Infrastructure Services January 25, 2018 Janet McClendon Sprint Spectrum, LP 8502 E. Via de Ventura, Suite 220 Scottsdale, AZ 85260 Re: OV1800091, Engineering Acceptance Letter for Type 1 Wireless Communication Facility (55 E. TANGERINE RD) Dear Ms. McClendon, Development Engineering has completed review of the subject project and has no comments. If you have any questions, please call me at (520)229-4824. Sincerely, Steve C Tineo, P.E. Senior Civil Engineer cc: File Oro Valley, it's in our nature. 11000 N. La Canada Drive, Oro Valley, Arizona 85737 www.orovalleyaz.gov I phone: (520) 229-4800 1 fax: (520) 742-1022 Y .4 OQ� Oy9 t, A1001YDED 191b. Town of Oro Valley Community Development and Public Works February 9, 2018 Janet McClendon Patricia Ramsey 8502 E. Via de Ventura, Suite 220 8502 E. Via de Ventura, Suite 220 Scottsdale, AZ 85260 Scottsdale, AZ 85260 Janet. mcclendon(asmartlinkllc.com Patricia. ram sey(cDsmartlinkllc.com Re: Tier II Communication Facility 55 E. Tangerine Road Action Letter (OV1703061/ OV1800091) Dear Ladies, During their regularly scheduled meeting on February 6, 2018, the Planning and Zoning Commission approved the proposed modifications to the existing Tier II Communication Facility, located at 55 E. Tangerine Road. The approved modifications do not require building permits, so you may proceed with installation. If you have any questions, please contact me at msimms@orovalleyaz.gov or 520-229-4836. Best regards, WL-9wAW-0 Milini Simms Planner msimms(@orovalleyaz.aov 520.229.4836 CC: File Oro Valley, it's in our nature. 11000 N. La Canada Drive, Oro Valley, Arizona 85737 www.orovalleyaz.gov I phone: (520) 229-4800 1 fax: (520) 742-1022