Loading...
HomeMy WebLinkAboutOV1802935"'%- oPO�ALLEY AR�0 TOWN OF ORO VALLEY COMMUNITY DEVELOPMENT & PUBLIC WORKS DEPARTMENT " 11000 N. LA CANADA DRIVE, ORO VALLEY, AZ. 85737 PHONE: (520) 229-4800 FAX: (520) 742-1022 '. www.orovalleyaz.gov MOUNDED A91% 1.2 GENERAL APPLICATION FORM Office OV Case #: 0A 1 �( Application Type ,< ❑ Major General Plan Amendment ❑ Final Plat f ^..r S� ❑ Rezoning/PAD Amendment ❑ Pre -Application s ❑ Planned Area Development ❑ Zoning Verification 1/ p 21018 ❑ Conditional Use Permit ❑ Sign Criteria ��** ❑ Zoning Code Amendment ❑ Sign - PAD Exemption° K'. •. ❑ Conceptual Site Plan ❑ Master Sign Program " ❑ Conceptual Public Art U Communication Facility — Tier 1 and 2 Minor ❑ Conceptual Architecture ❑ Communication Facility — Major ❑ Final Site Plan ❑ Revised Development Plan ❑ Conceptual Landscape Plan ❑ Other Subject Property Information: Address: In a TEP ROW SW of N La Canada Dr. & W Lambert Ln Parcel/Tax Code: Subdivision / Commercial Center Name: Book / Page or Sequence Number: Legal Description: Section/Township/Range: N/A - TEP ROW Lot Number(s Area of Property: Existing Land Use: Verizon Wireless Antennas attached to TEP Proposed Land Use: Same pole Applicant Information: Applicant *: * If more than one, attach list Name: Carmelina Scigliano Firm: Tectonic Engineering Consultants, P.C. on behalf of Verizon Wireless Address: 3923 S McClintock Drive Suite 409 Clty: Tempe State: AZ— Zip: 85282 _ Telephone: 520-241-2388 Fax: N/A Email: CScigliano@Tectonicengineering.com Property Owner(s) if different from Applicant *: Name: Anna M. Garcia Firm: Tucson Electric Power Company Address: TEP, Attn: Telecom Rep., 220 W. 6th Street City: Tucson State: AZ Zip: 85701 Telephone: 520-916--8360 Fax: N/A Email: Annagarcia(a)TEP.com Consultant: Engineer (Discipline) Name: Adrian Massie, P. E. Firm: Tectonic Engineering Consultants, P.C. Address: 3923 S McClintock Drive, Suite 409 City: Tempe State: AZ Zip: 85282 Telephone: 480 629-5533 Fax: N/A Email: AMassie@tectonicengineering.com Project Description/Narrative: Verizon Wireless proposes modifications to an existing communication facility on a TEP utility pole. This modification will maintain the operation of this public utility / personal wireless service with the latest technological advances. I hereby certify that I have read and examined this application and know the same to be true and correct. I am the owner of the property or the Owner's authorized representative, and if not the owner, I have obtained the owner's permission to perform stated work. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The approval of this application does not presume to give authority to violate or cancel the provisions of any other federal, state or local law for which this project may be subject to. Notice: It is the applicant/owner's responsibility to ensure all private rules and regulations (such as Covenants, Conditions & Restrictions (CC&R's)) of the subdivision and/or commercial center are adhered to. Contact your Home Owners Association or property management to determine applicable requirements. It is also the applicant's responsibility to coordinate with all outside agencies to secure their acceptance or clearance. Failure to do so may delay issuance of permits. See attached list of agencies. Carmelina Scigliano 11/02/2018 Applicant's Si nature Print Name Date Important Note: All submittals received after 4:00 p.m. will be processed the next day Submittals will be rejected if: • Not folded using Pima County fold & collated; • There are missing items on the checklist unless otherwise approved by Planning and Zoning Administrator or Town Engineer. • Re -submittals cannot be accepted without a transmittal and a written response to staff comments. 2 October 25, 2018 Town of Oro Valley Community and Economic Development Department 11000 N. La Canada Drive Oro Valley, AZ 85737 RE: Verizon Wireless - Proposed cell modifications Near the SWC of Lambert Lane and La Canada Drive Pre -application letter, OV1802703 To whom it may concern: The attached General Application is for proposed modifications to an existing cell facility on a TEP utility pole, located near the southwest corner of Lambert Lane and La Canada Drive. This modification will maintain the operation of this public utility / personal wireless service with the latest technological advances. Review and Approval Process - Comments/Responses: Comment: The voltage for any ground equipment being replaced is needed to determine if building permits will be required. Please include information with the formal submittal. Response: The shelter has a 200A 120/240V single phase service from Tucson Electric. The changes inside the shelter, are adding 2 over voltage protection (OVP) shelves (these are essentially circuit breakers to protect the equipment in the case of lightning strike on the tower), and changing out the software and hardware that processes the radio information from the antenna. This software and hardware are run by the existing DC power plant inside the shelter, that is powered by the existing 200A 120/240V single phase service panel inside the shelter. That is what we mean by'like for like' changes. A simple analogy would be like if you changed your cable box router in your house. Comment: A right-of-way permit is required for any work in the public right-of-way. Response: A right of way permit will be applied for when zoning is approved and prior to site work beginning. Proposed Plan — Comments/Responses: Comment: All communications facilities, regardless of tier classification, must utilize stealth applications to the greatest extent possible (Section 25.1.B.5.ii.a). Staff suggests placing the antennas closer to the pole, using shrouds around the antennas, or painting them to match the pole to reduce visual impact. Response: Verizon will utilize an antenna mount that places the antennas as close as possible to the pole and paint the antenna to match existing. Comment: Above ground equipment should be completely screened by an architecturally compatible solid wall or opaque fence (Section 25.1.13.5.b.ii.d.2). As such, include height of existing screen wall to ensure the new ground equipment will be fully screened. Response: Verizon has an equipment shelter and generator inside a CMU walled compound. The walls of the compound are high enough (-10' or so) to screen the shelter from view at ground level. The height of the CMU wall has been noted on the drawings. The proposed Verizon Wireless cell facility modification will meet the code requirements of the Town of Oro Valley. Your time and consideration is greatly appreciated! Regards, Carmelina Scigliano Sr. SAQ PM Representing Tectonic Engineering Master Acquisitions 520-241-2388 Cscigliano@tectonicengineering.com 1_ TEP Tucson Electric Power P.O. Box 711, Tucson, AZ 85702 4350 East Irvington Road Tucson, Arizona 85714 Anna M Garcia, Project Manager (OH2O4) Resource Management/Telecommunications Department September 24, 2018 Oro Valley Development & Infrastructure Services 11000 N La Canada Dr Oro Valley, AZ 85737 520-918-8360 e-mail: ACabrera@tep.com RE: Verizon Wireless Site — TUC El Conquistador, 10375 N La Canada Dr., Conversation 715818 Dear Ms. Scigliano: Let this letter serve as notice that Tucson Electric Power Company continues to have an agreement with Verizon Wireless to install antennas on a TEP pole located at 10375 N La Canada Dr. Tucson Electric Power Company is responsible for the installation of antennas and cable on its poles and structures and assures that the structural requirements for the antenna installation are adequate and meet or exceed Tucson Electric Power Company standards as well as the National Electric Safety Code. Verizon Wireless is responsible for any permits and or zoning requirements for the installation of wireless communication equipment. If I can be of any further assistance, please do not hesitate to call me at 918-8360. Sincerely, Anna M Garcia Project Manager :ag cc: C. Scigliano .. 1 VERIZON WIRELESS SITE NAME: TUC —EL —CONQUISTADOR EXISTING 69' UTILITY POLE 10375 N. LA CANADA DR. ORO VALLEY, AZ 85737 MOUNT ANALYSIS REPORT October 11, 2018 Tectonic- PP4[T [Fl SI��IIIIfINS..Y[:PTINI�FI S PYIf F. W.O. 8664. TUC EL CONQUISTADOR } 4. Tectonic 11 October 11, 2018 RE: ANTENNA MOUNT STRUCTURAL ANALYSIS PROPOSED ANTENNA AND EQUIPMENT UPGRADE VERIZON WIRELESS SITE NAME: TUC_EL_CONQUISTADOR VERIZON SITE ID: TUC —EL —CONQUISTADOR SITE ADDRESS: 10375 N. LA CANADA DR., ORO VALLEY PIMA COUNTY, AZ 85737 TECTONIC W.O. NUMBER: 8664. TUC EL CONQUISTADOR This letter is to confirm that Tectonic Engineering Consultants P.C. (Tectonic) has performed a structural analysis of the proposed Verizon Wireless antenna mounting system on the site noted above. The intent of this review is to determine if the load from the proposed modification of appurtenances is within the structural capacity of the proposed antenna mounting system and that the strength requirements for the mounting system are met in accordance with the Verizon Wireless Standard NSTD-445 "Antenna Mounting System Classification Standard", last modified 6/29/17. For the purpose of the analysis, Verizon Wireless provided the following information: • Site Photos. • RF Antenna Design Sheet, "Site Name: Tuc El Conquistador, RFDS Project ID: 1290619," by Verizon Wireless, dated, 07/25/18. • Mount Engineering Letter by Site Prol/Valmont Mounting System: Part Number: RMQP- XXX" by SiteProl, dated 9/8/2017. Based on RF Antenna Design Sheet and site data referenced above, Verizon Wireless currently has three (3) panel antennas (one per sector) and three (3) TMA units mounted on a pipe mount secured along the top of the existing utility pole. The following table displays the existing Verizon Wireless antenna and equipment configuration: Henrico Office 3951 Western Parkway, Suite 160 1 Henrico, VA 23233 804.217.8504 Tel 1 804.270.0503 Fax tecto nicengincering. com Equal Opportunity Employer 1 Tectonic Existing Verizon Wireless Loading: RAD Height Quantity Antenna Model No. 73.8' 6 AMPHENOL - HTXCW631518R000G 73.8' 3 ANTEL - TTA-TWG020H * Items in bold are to be removed Verizon Wireless upgrade consists of removing all of its equipment including the antenna mounting pipe from the utility pole. Verizon Wireless is proposing to extend the existing utility pole so as to accommodate an antenna mounting system. Nine (9) panel antennas (three per sector), six (6) remote radio head units (two per sector), six (6) diplexer (two per sector) and one (1) OVP box are to be installed on the proposed antenna mounting system as part of this upgrade. The following table displays the final Verizon Wireless antenna and equipment configuration: Proposed Verizon Wireless Loading: RAD Height Quantity Antenna Model No. 76' 9 JMA WIRELESS - MX08FRO860-02 76' 3 ERICSSON - B13/ B5 RRH 76' 3 ERICSSON - B2/ B66A RRH 76' 6 COMMSCOPE - CBC78-DF-8-DCB-2X 76' 1 RAYCAP - OVP BOX * Items in bold are proposed to be installed. Based on the documents referenced, the proposed mounting system is a low -profile platform (PN# RMQP-3XX), as manufactured by SiteProl. Verizon Wireless requires all antenna mounting systems to be reviewed in accordance with NSTD 445 "Antenna Mounting System Classification Standard". The Standard is a means to outline the required strength of an antenna mount for a specific site and will allow for an efficient evaluation in the future if loading changes are required. The Standard is to be used in conjunction with the TIA (Telecommunications Industry Association) Mounting System Classification (TIA/TSB-5053), and the ANSI/TIA 222 G Standard. In accordance with NSTD 445, Section 9.3, the effective projected areas at single mounting pipes are to be determined in compliance with ANSI/TIA-222-G "Structural Standard for Antenna Supporting Structures and Antennas". As such, the analysis has been performed using the following design criteria: 8664. TUC EL CONQUISTADOR 2 i Tectonic 1 • Basic Wind Speed, V = 89 mph* • Wind Speed with Ice, V;,e = 0 mph • Service Wind Speed, VS = 60 mph • Ice Thickness, t; = 0 inches • Mount Height, z = 73.8 feet • Structure Class = II • Exposure Category = C • Topographic Category = 1 * The ultimate 3-second wind gust speed of 115 mph is converted to a nominal 3-second gust wind speed of 89 mph per section 1609.3.1 of the 2012 International Building Code, for the use in the TIA-222-G Standard per exception 45 of section 1609.1.1. According to our calculations for the low profile platform, the maximum factored concentrated force required (in accordance with NSTD) to be supported at each mounting pipe location is 600 lbs. Therefore, the minimum mount classification number required for the proposed appurtenance loading is "M600R-3(6)". Per NSTD-445 Section 10, the minimum mount classifications for each region are listed according to maximum design wind speeds and ice thicknesses based on the site location. As such, the minimum Verizon Wireless required mount classification based on the site location would be M750R-4[6]. Based on the documents referenced above, the proposed low profile platform (SiteProl PN # RMQP-496) has antenna mount classification rating of "M100011 (700)-4[6]. Since the antenna mount manufacturer has a pre -specified classification rating, which is greater than that required at this site location, the proposed low profile platform is adequate to support the proposed antenna upgrade. No further analysis is required. Based on above, we conclude that the proposed antenna mounting system has sufficient reserve capacity to support the proposed Verizon Wireless upgrade in accordance with the NSTD Standard. This structural analysis is based on the site photos and the documents referenced above. The contractor shall therefore, field verify existing conditions and notify the design engineer of any discrepancies prior to installation of the proposed upgrade. Any further changes to the antenna or other appurtenances configuration and location should be reviewed with respect to their effect on structural loads prior to implementation. 8664. TUC EL CONQUISTADOR 3 Tectoom,61 Analysis of the existing supporting tower structure is to be completed by others and is therefore, not part of this analysis report. Analysis of the antenna mounting system as a tie -off point for fall protection or rigging is not part of this document. It has been a pleasure working with you on this project. Should you have any questions, please do not hesitate to contact us. Sincerely, Tectonic Edward F. Martella, P.E. Vice President 8664. TUC EL CONQUISTADOR NSTD-445 CLASSIFICATION 1 • r,; Job No.: 8664 - TUC EL -CONQUISTADOR TectonicSheet No.: 1 of 6 Calculated By: SM Date : 10/11 /18 `"a`r""5°`lTIatlS.EX(E—O""`SERVICE, Checked By: KZ Date : 10/11/18 WIND AND ICE LOADS PER TIA-222-G W.O. 8664 - TUC EL -CONQUISTADOR Project Name TUC EL -CONQUISTADOR Location 10375 N. La Canada Dr., Oro Valley, AZ 85737 County Pima Tower Type MP Monopole Structure Class 2 Substantial hazard Exposure Category C Open terrain Topo Category 1 Flat or rolling terrain Height of crest 0 ft Importance Factor Wind only 1.00 8664 TUC El Conquistador- Wind Loading NSTD Loading.xlsx WindLoads-TIA-G Job No.: 8664 - TUC_EL-CONQUISTADOR Tectonic Sheet No.: 2 of 6 Calculated By: SM Date : 10/11/18 P 11ACTICAL SULUTIGNS. ERCEI1II0NAL SERVICE. Checked Bv: KZ Date : 10/11/18 Section 9.1.3 LIMITATIONS (Page 10) Structure Height 76 s 400 feet Good Structure Class or Risk Category II Category I or II Good Exposure category C Category B or C Good Topographic Category 1 Category 1 Good 50-year return, 3-second gust basic wind speed 89 Max 140 mph Good Ultimate 3-second gust wind speed based on risk category 115 Max 180 mph Good 50-year return design ice thickness 0 Max 1 inch Good Ultimate design ice thickness based on risk category 0 Max 2 inch Good Basic wind speed occurring simultaneous with ice 0 Max 60 mph Good Factored wind pressure without ice at mounting elev. 36.82 aM(gz)( Gh) <_ 135 psf Good Factored ice thickness at mounting elevation 1 0.00 tiz <_ 2.75 inches Good Factored wind pressure with ice at mounting elevation 1 0.00 JaM (qz)( Gh) s 15 psf Good All limitations have been satisfied, therefore, mount classifications may be used to determine the suitability and/or requirements of the mount at this location per Sections 9.1 and 9.2 of NSTD-445 Tectonic rm Job No. 8664 - TUC_EL-CONQUISTADOR Sheet No. 3 or 6 Calculated By SM Date: 10/11/18 Checked By KZ Date: 10/11/18 Sheilding Factor Ka =1 0.9 1 NSTD-445 Sec 9.3 Wind Only Load Combinations Alpha sector is considered for detailed analysis Antenna Configuration (E) or (P) Quantity =(ff) Length or Diameter (ft) Width (in) Depth (in) Flat or Cylindrical? Antenna (Ca)T Antenna (Ca)N Face Normal (Aa)N (ftA2) Windward face Normal (CaAa)N Each (ftA2) Side Face (Aa)T (ftA2) Windward Side Face (CaAa)T Each (ftA2) Normal Antenna Wind Load Each (lb) Transverse Antenna Wind Load Each (lb) Antenna Weight (lb) Total Weight (lb) MXDBFROB60.02 P 9 76 7.99 15.40 10.70 Flat 1.47 2.00 3.46 6.23 7.13 9.40 143 216 95.0 855.0 B13165 RRH P 3 76 1.25 13.20 9.30 Flat 1.20 1.20 1.38 IIAS 0.97 1.05 34 24 70.0 210.0 B2/B66A RRH P 3 76 125 13.26 11.10 Flat 1.20 1.20 1.38 1.49 1.16 1.25 34 29 75.0 225.0 CBC78-DF-8-DC8-2X P 1 6 76 0.66 5.90 5.70 Flat 1.20 1.20 1 0.32 0.35 0.31 0.34 8 B 13.9 83.4 OVP BOX P I 1 76 2.41 15.73 10.31 Flat 1.21 1.20 1 3.16 3.41 2.07 2.26 79 152 32.0 32.0 tPPAWPH 1.73 1 40 ( 40 lFPAWPT Weinhl Mount Location 1: 7.96 (ftA2) 11.13 (ftA2) 124.28 Ibs Mount Location 2: 10.14(ftA2) 12.85 (ft^2) 222.08 Ibs Mount Location 3: 12.85 (ftA2) 1 14.64 (ft^2) 226.28 Ibs 8664 TUC El Conquistador- Wind Loading NSTD Loading.xlsx Appurtenance Job No.: 8664 - TUC EL -CONQUISTADOR Tectonic Calculated By: SM Date : 10/111/18 Checked By: KZ Date: 10/11/18 PROJECTED AREA AND WEIGHT/MOUNT PROJECTED AREA AND WEIGHT/MOUNT Mount Type: PLATFORM No. of Pipes: 3 Vertical Offset 6 inches Required Reserve 10 (EPA)MPN = 12.85 (ff^2) (EPA)MPT = 14.64 (ff^2) (EPA)MPN (i)= 0.00 ((t^2) (EPA)MPT(i) = 0.00 (ft^2) Wl= 226 Ibs Wt (ice only)= 0 Ibs FORCES PER MOUNT LOCATION F°° = 473 Ibs, each F,° = 539 Ibs, each FZ° = 272 Ibs, each F,,; = 0 Ibs, each F,; = 0 Ibs, each F„ = 0 Ibs, each FOR MOUNT CATEGORY "R" "F" shall be the larger of the following: 1.00 x (Fno) 473 Ibs 1.00 x (Fto) 539 Ibs 2.00 x (Fzo) 543 Ibs 4.00 x (Fni) 0 Ibs 4.00 x (Fti) 0 Ibs (Fzi) 0 Ibs (Fzi) = 0 Ibs, with 10 %reserve Therefore (Fzi) = 0 Ibs F (max) = 543 Ibs F (ult) = 597 Ibs, with 10 %reserve Therefore, F = 600 Ibs Min Req'd Mount Classification: M60QR(0)-3[6] Min Mount Classification (VZW): M750R(0)-4[6] e PRO A valmont V COMPANY September 8, 2017 1545 Pidco Drive Plymouth, IN 46563 Phone: S74.936.4221 Fax: S74.936.8925 Frnail: SP1Ergincering@valmont.com www.siteprol.com Site Pro 1 / Valmont Mounting System: Part Number = RMQP-xxx Part Description = 12' Low Pro -Platform Mount EPA & Weight (no antenna pipes): EPAN = 25.04 Sq-Ft EPAT = 23.89 Sq-Ft Weight = 1205 lb Classification Rating: M 1000R(700)-4[6] Design Standards EPAN (0.5" Ice) = 29.39 Sq-Ft SPAT (0.5" Ice) = 28.23 Sq-Ft Weight (05' Ice) =1475 lb ANSI/TIA-222-G-2012 ASCE 7-10 International Building Code 2012 Verizon Network Standard NSTD-445 1/16/17 Analysis and Modeling Technique EPAN (1" Ice) = 34.02 Sq-Ft EPAT(r" Icc) = 32.62 Sq-Ft Weight (1"Ice) = 1815 lb An elastic three-dimensional frame truss model was created to analyze the mount. The mount was modeled with four (4) mounting locations (antenna, radio etc. + pipe) evenly spaced across the face of the mount, with a 6" vertical eccentricity. Wind directions considered were perpendicular (normal) to the face of the frame and at 30 degree increments up to 90 degrees (tangential) to the face of the frame. Wind, dead weight and ice weight on the mount was also included in the model. Modeling Software Autodesk Inventor R I SA-3 D ANSYS Workbench New York Georgia Indiana Oregon Callfonla texas Florida -888-438-7761 1-866-901-0603 1-888.753 7446 1.888-880-9191 1.888-776-1937 1-888.809 5151 1-844-278.6371 I SITE 1545 Pid i, Clive Plymouth, IN 46563 PRO Phone: 574.936.4221 Fac S74.936.8925 Finail. SP16-,gineering@vdlrnunt.c.on'i A vahnont V COMPANY www.siteprol.com Analysis Design Criteria Maximum Mount Height 400' Maximum Ultimate Wind Speed, no Ice 180 mph 3 sec gust Maximum Design Wind Speed, no Ice 140 mph 3 sec gust Maximum Design Wind Speed on Ice 60 mph 3 sec gust Structure Class I or II Exposure Category B or C Topographic Category I Maximum Design Ice Thickness, ti 1" (2.75" factored ice) Wind Direction Probability Factor, Kd 0.95 Gust Effect Factor, Gh 1.0 Capacity Results The following factored loads at each mounting location represent the capacity of the mount based on the criteria and modeling technique described above. Normal Wind Load (no ice), Fno .....................1000 lb [625 lb Non -Factored] Tangential Wind Load (no ice), Ft. .....................1000 lb [625 lb Non -Factored] Vertical (Dead) Load, FZo .....................500 lb [417 lb Non -Factored] Normal Wind on Ice, Fr,i .....................175 lb Tangential Wind on Ice, Fti .....................175 lb Vertical (Dead + Ice) Load, FZi .....................700 lb Normal Maintenance Wind Load, Fnrn .....................100 lb Tangential Maintenance Wind Load, Fir, .....................100 lb Vertical Dead Load, FZm .....................500 lb [417 lb Non -Factored] Vertical Live Load. LM* .....................750 lb [500 lb Non-Factoredl * In addition to a nominal Live Load of two (2) 250 lb concentrated on either side of a mounting location to provide access for climbers. New York Georgia Indiana Oregon Cahlonla Texas Florida 1-888-438-7761 1-866-901-0603 1-886-753-7446 1-888-880.9191 1-888-776-1937 1-888-809.5151 1-844-278.6371 U V. Im An r + off'. ,^f + OP ! a air *i1 'i+� " r! • r4 A a � • •� !{ • �� �� • Orr :� p 4. « • i �: 71�•� i F.h� to *� �. 1� •� t � ��t• " � � i a 1f �' j • • N it 41 amlE 0 ft *—, �M a r� x� tom• 3 t s•. "its, .� ,� t-'-� . a e . " de o•, w "*` ��= Fla°�, � «*, its• . ; r !� " *�•" s' a �4� v MR Ato a l; 4 •ii' *i,='ay✓l f -<•.` TTT ai(y 7f)� i~ yr tot �V1 v { 1 < , i � � `;�'�ai��- it w =_.s.fl,'.1�.. i i•J+ �V i� °` ""''k. � .. — ��FF a LLL�ii _. TUC El Conquistador PHOTO • 10375 North La Canada Drive LOG Oro Valley, Arizona 85737 8664.EIConquistadi Looking southeast from West Lambert Lane. P- • Proposed installation will be visible from this location. Distance from the photographic location to the proposed site is 275'± 8664.EIConquistadoi Looking southeast from West Lambert Lane. S-1 Proposed installation is visible from this location. Distance from the photographic location to the proposed site is 275'± verizon SITE NAME: TUC EL CONQUISTADOR PCS/850/AWS-3/4XTX/ERICSSON CARRIER ADDITIONS TO OBTAIN LOCATION OF PARTICIPANTS UNDERGROUND FACILITIES BEFORE YOU DIG IN ARIZONA, CALL ARIZONA 811 TOLL FREE: 1-800-7825348 OR -.ad.ona811.com I� ARIZONA STATUTE Know whars b2IOW. REQUIRESMINOF2 WORKING DAYS NOTICE Call before you dig. BEFORE YOU EXCAVATE VICINITY MAP SPRINGS ESTATES CANADA. Rt.GE MASTER HILL } CARLIEI ROINTE EIS T�vn9 MOUTE SEE TIRO CANADA HILLS -- CANAEA HILLS ESTATES � n CANADA TA '--SITE THE TO =saeeD u EL CONOUI ADDR OtR R„Mtrn COUNT Cl UB PM `"t'�" LAMBERT LANE PggRAL % THE VILLAGES IGHTS OF LA. CANADA ORO VALL ESTATES am V,nq F TECOLOTE VALORO ESTA DE ORD LOMAS OE TIRO ORO V CANYON nFIG SHADOWS q SADDLE VALLET I DIRECTIONS I DIRECTIONS TO SITE FROM VERIZON WIRELESS TEMPE OFFICE: 1. MERGE ONTO 1-10 E (86.4 MI) 2. TAKE EXIT 244 TOWARD TWIN PEAKS ROAD AND TURN LEFT 3. TURN RIGHT ONTO W LINDA VISTA BLVD 4. TURN LEFT ONTO N THORNYDALE RD 5. TURN RIGHT ONTO W PECOS WAY 6. CONTINUE ONTO W LAMBERT LN 7. TURN RIGHT ONTO N LA CANADA LN 8. DESTINATION WILL BE ON THE RIGHT 10375 N LA CANADA DR ORO VALLEY, AZ 85737 COUNTY OF PIMA PROJECT SUMMARY PROJECT NUMBER: 20181799413 LOCATION CODE 157557 SITE NAME: TUC EL CONQUISTADOR SITE ADDRESS: 10375 N LA CANADA DR ORO VALLEY, AZ 85737 JURISDICTION: TOWN OF ORO VALLEY COUNTY: PIMA COUNTY TAX MAP PARCEL ID: 224-39-001C COORDINATES (NAD83): N 32' 23' 42.47' (32.395137) W 1IT 59' 48.35- (-110.996764') GROUND ELEVATION (NAVD88): 2552.5't AMSL ZONING CLASSIFICATION: PCD STRUCTURE TYPE UTILITY POLE PROPERTY OWNER: TEP 220 W BTH ST CONTACT: TUCSON. AZ 85701 ANNA GARCIA PHONE (520) 916-8360 APPLICANT: TECTONIC ENGINEERING FOR VERIZON WIRELESS 3923 S McCLINTOCK DR, STE 409 TEMPE, AZ 85282 CONTACT: PHONE CARMELINA SCIGLIANO (520) 241-2388 ENGINEER- TECTONIC ENGINEERING CONSULTANTS, P.C. 3923 S McCUNTOCK DR, STE 409 CONTACT: TEMPE, AZ 85282 ADRIAN MASSIE, P.E. PHONE (480) 629-5533 LEASING do ZONING: TECTONIC ENGINEERING CONSULTANTS, P.C. 3923 S McCUNTOCK OR, STE 409 CONTACT: TEMPE, AZ 85282 CARMEUNA SCIGLIANO PHONE (520) 241-2388 SURVEYOR: N/A CONTACT: N/A PHONE N/A SHEET INDEX ENV DESCRIPTION N0. THIS SET OF PUNS SHALL NOT BE UTIUZED AS CONSTRUCTION DOCUMENTS UNTIL ALL ITEMS OF CONCERN HAVE BEEN ADDRESSED AND EACH OF THE DRAWINGS HAS BEEN REVISED AND ISSUED 'FOR CONSTRUCTION'. CODE COMPLIANCE ALL WORK AND MATERIAL SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE LOCAL CODES. CODE TYPE COOS I PROPRIETARY INFORMATION NOT FOR USE OR DISCLOSURE OUTSIDE BUILDING 2012 NTERNATIONAL BUILDING CODE VERIZON WIRELESS EXCEPT UNDER WRITTEN AGREEMENT. MECHANICAL 2012 NTERNATIONAL BUILDING CODE ELECTRICAL 2011 NATIONAL ELECTRIC CODE APPROVALS APPROVED BY DATE I NITIALS COMMENTS RF ENGINEER SITE DEV. SITE ACQ. PM DO NOT SCALE DRAWINGS THESE DRAWINGS ARE FORMATTED FOR 22X34'. OTHER SIZED VERSIONS ARE NOT PRINTED TO THE SCALE SHOWN. CONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS k CONDITIONS ON THE JOB SITE h SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. PROJECT DESCRIPTION MODIFICATION TO AN EXISTING VERIZON WIRELESS UNMANNED TELECOMMUNICATIONS FACILRY TO CONSIST OF THE FOLLOWING: 1. REMOVE (3) EXISTING PANEL ANTENNAS 2. REMOVE (3) EXISTING TMAS FROM TOWER 3. REMOVE (6) UNES OF 7/8- COAX 4. INSTALL NEW PLATFORM MOUNT 5. NSTALL (9) NEW PANEL ANTENNAS 6. INSTALL (6) NEW DUAL BAND RRU. 7. INSTALL (6) NEW DUAL DIPLEXERS 8. NSTALL (1) NEW OVP-12 9. INSTALL (1) NEW 12.24 HYBRID CABLE VERIZON WIRELESS RF DESIGN = JULY 25, 2018 GENERAL NOTES 1. PRIOR TO SUBMITTING A BID, THE CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE SCOPE OF WORK AND ALL CONDITIONS AFFECTING THE NEW PROJECT. 2. CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS AND DIMENSIONS OF THE JOB SITE AND CONFIRM THAT WORK AS INDICATED ON THESE CONSTRUCTION DOCUMENTS CAN BE ACCOMPLISHED AS SHOWN PRIOR TO COMMENCEMENT OF ANY WORK. 3. ALL FIELD MODIFICATIONS BEFORE, DURING, OR AFTER CONSTRUCTION SHALL BE APPROVED IN WRITING BY A VERIZON WIRELESS REPRESENTATIVE. 4. INSTALL ALL EQUIPMENT AND MATERIALS PER THE MANUFACTURER'S RECOMMENDATIONS, UNLESS INDICATED OTHERWISE 5. NOTIFY VERIZON WIRELESS, IN WRITING, OF ANY MAJOR DISCREPANCIES, REGARDING,' THE CONTRACT DOCUMENTS, EXISTING CONDITIONS, AND DESIGN INTENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATIONS FROM A VERIZON WIRELESS REPRESENTATIVE, AND ADJUSTING THE BID ACCORDINGLY. B. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES OF THE WORK UNDER THE CONTRACT. 7. CONTRACTOR SHALL PROTECT ALL EXISTING IMPROVEMENTS AND FINISHES THAT ARE TO REMAIN. CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY OCCUR DURING THE CONSTRUCTION TO THE SATISFACTION OF A VERIZON WIRELESS REPRESENTATIVE. 8. CONTRACTOR PLANS TO ILLUSTRATE THE AS -BUILT CONDITION OF THE SITE. FOLLOWING THE FINAL INSPECTION BY VERIZON WIRELESS, THE CONTRACTOR SHALL PROVIDE VERIZON WIRELESS WITH ONE COPY OF ALL RED -LINED DRAWINGS. 9. VERIFY ALL FINAL EQUIPMENT WITH A VERIZON WIRELESS REPRESENTATIVE. ALL EQUPMENT LAYOUT, SPECS, PERFORMANCE INSTALLATION AND THEIR FINAL LOCATION ARE TO BE APPROVED BY VERIZON WIRELESS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THEIR WORK WITH THE WORK AND CLEARANCES REQUIRED BY OTHERS RELATED TO SAJD INSTALLATIONS. vwlZonA/ 126 W GEMINI DR TEMPE. AZ 85283 Tec_ton_hP T 3 OglnrYip Cavut!•arRa P.GEON� T t. KN NCCIIntoek OT. �� E - I ,m www tectonlcenglneering.com� 18664.TUC EL CONQUISTADOR I JI MR 0 9/21/18 FOR COMMENT 1 10/31/18 FOR PERMIT HELIASEU BY LATE O e `� PALFICq Teo P 4 65322 0 u ADRIAN - m gpMASSIE " 9 ed 1 F 4pVlOS COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE OF THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VALE) COPIES. O 2 3 ORIGINAL SIZE IN INCHES SITE INFORMATION TUC EL CONQUISTADOR 10375 N LA CANADA DR ORO VALLEY, AZ 85737 PIMA COUNTY VZW LC: 157557 VZW PN: 20181799413 SHEET TTTLE TITLE SHEET SHEET NUMBER T-1 II GENERAL NOTES II 1. THIS PROJECT CONCERNS THE INSTALLATION, MAINTENANCE, AND OPERATION OF A PUBLIC URLRY/PERSONAL WIRELESS SERVICE. 2. THE PROPOSED UPGRADE IS UNMANNED AND DOES NOT REQUIRE A MEWS OF WATER SUPPLY, SEWAGE DISPOSAL. OR HANDICAPPED ACCESS. 3. THE PROPOSED UPGRADE 15 MINIMAL, WILL CREATE NEGLIGIBLE ADDITIONAL STORMWATER RUNOFF, AND WILL, THEREFORE, NOT IMPACT THE EXISTING STORMWATER DRAINAGE SYSTEM. 4. THE PROPOSED UPGRADE DOES NOT INCLUDE OUTDOOR STORAGE, SOLID WASTE RECEPTACLES, OR PLUMBING. S. ADEQUATE PARKING EXISTS FOR ONE VEHICLE FOR MANTENANCE OR EMERGENCY SERVICE ONCE A MONTH. 8. THERE ARE NO NEW STREETS, CURBS, SIDEWALKS, OR WALKWAYS PROPOSED. 7. THERE ARE NO COMMERCIAL SIGNS PROPOSED FOR THIS UPGRADE SITE NOTES: 1. ALL WORK SHALL BE AS INDICATED ON THE DRAWINGS. 2. DEBRIS AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. • CONTRACTOR SHALL NOTIFY ARIZONA 811 BY DIAUNG 811 PRIOR TO EXCAVATION AT SITE • CONTRACTOR TO LOCATE AND VERIFY ALL EXISTING UNDERGROUND UTILITIES PRIOR TO EXCAVATION • ALL EXCAVATION WORK WITHIN 36' OF EITHER SIDE OF UNDERGROUND UTUTIES MUST BE DONE BY HAND EXCAVATION MEHODS 11 SITE INFORMATION BASED ON A SITE VISIT PERFORMED BY TECTONIC ENGINEERING CONSULTANTS ON 9/4/18, AND DRAWINGS BY 8K DESIGNS DATED 1/4/14. I \ \ SEE ENLARGED SITE \\\ PUN ON SHEET C-2 \\ I OHW OHIN —�OHW I— OHW I I EXISRNG OVERHEAD POWER EXISTING BUILDING (TYP) W LAMBERT UN �\ EXISTING ACCESS APN: 224-39-001C EXISTING PROPERTY LINE n OVERALL SITE PLAN C-1 SCALE: 1' - 20- (22.34 SIZE) 1' 40' (11.17 SIZE) vwlZonAl 125 W GEMINI DR TEMPS, AZ 85283 Tectonic Inurnnl wtmora loanarM �svla. 9 1`elsus� fari4lsK� RG W ww.tsetontcongf—rinq.eom 18664.TUC EL CONQUISTADORI I JMR 1 0 9/21/18 FOR COMMENT 1 10/31/10 FOR PERMIT Ntl.k/LSED 9Y GATE a esw 66322 O ADRIAN e MASSIE A B i0I> F CONES OF THIS DOCUMENT WJDHDUT A FACSIMILE OF THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL SCAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIOERED VA1D COPIES. 1 2 3 ORIGINAL SIZE IN INCHES SITE INFORMATION TUC EL CONQUISTADOR 10375 N LA CANADA DR ORO VALLEY, AZ 85737 PIMA COUNTY VZW LC: 157557 VZW PN: 20181799413 SHEET TITLE OVERALL SITE PLAN SHEET NUMBER C-1 TW OHW OHW OHW OHM OFTW OHW OHW T\\\ N- VE-Xt—STNG OHW OMW OHWOHWDOSTINGEXISTING TEP OVERHEAD POWER UTIIm• POLE DOGHOUSE__ _ — EXISTING PROPERTY LINE 1 1 1 EXISTING VERZON WIRELESS (8) 7/8• COAXCOAX TO BE REMOVED 1� TO REMA N IN EXISTING.U/ CONDUITS PROPOSED VOCON W RElES4 (1) 12124 HYBRID CASE IN1IDOSTRR' U/G CONDUIT 11 EXISTING VERIZON WIRELESS EQUIPMENT SHELTER IX EXISTING VERRON WIRELESS GENERATOR .. I 1 Fl J i -'f fi fi EXISTING CMU WALL EXISTING WAG UNIT EXISTING SLIDING ACCESS GATE 1 �i DETAILED SITE PLAN C-2 SCALE: 1' 3' (22x74 SIZ 1• - B' Itx17 SIZE) EXISTING CMU RETAINING WA11 verizon%l 128 W GEMINI DR TEMPE. AZ B5283 TectonO SSIiCn[At W YTee11L E�II W l SOYIO. Talwiis CgNrM Cgrllleb �F � 342J SeuN YaGInNe4 p. Su14 ba PNen- (b0) 12F6S.11 1w..pw K e4242 S00 424-0.5J1 n WAVW.tectonicengineertnq.com in WORK ORDER NUMBER 664.TUC EL CONQUISTADOR JMR I R 0 9/21/1811 FOR COMMENT 1 10/31/18 FOR PERMIT faaEASW BY DATE I i Op VE LOAiF'4 e^ 65322 O u ADRIAN _- m o MASSIE ` COPIES OF THIS DOCUMENT WrrHOUr A FACSIMILE OF THE SIGNATURE AND AN ORIGINAL EMBUSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VALID COPIES D 1 2 3 ORIGINAL SIZE IN INCHES SITE INFORMATION TUC EL CONQUISTADOR 10375 N LA CANADA DR ORO VALLEY, AZ 85737 PIMA COUNTY VZW LC: 157557 VZW PN: 20181799413 SHEET TTTLE DETAILED SITE PLAN SHEET NUMBER C-2 STRUCTURAL NOTE THIS VIEW DEPICTS THE PROPOSED VERIZON WIRELESS UPGRADES TO THE EXISTING MONOPOLE R DOES NOT INFER THAT TECTONIC HAS EVALUATED ITS STRUCTURAL ADEQUACY FOR THE NEW LOADS IMPOSED. THIS MONOPOLE WILL NEED TO BE EVALUATED BY A PROFESSIONAL ENGINEER TO CONFIRM MONOPOLE HAS CAPACITY TO SUPPORT NEW LOADS PRIOR TO CONSTRUCTION. ANTENNA MODIFICATIONS EXISTING ANTENNAS PRIOR TO UPGRADE 3 PROPOSED ANTENNAS AFTER UPGRADE: 9 II ANTENNA CONFIGURATION II UPGRADES INCLUDE (3) REPLACEMENT PANEL ANTENNAS (TYPE 1) (B) NEW PANEL ANTENNAS (TYPE 1) (2 PER SECTOR) (6) NEW DUAL BAND RRUS (2 PER SECTOR) (6) NEW DUAL DIPLEXERS (1) NEW OVP-12 (1) NEW 12x24 HYBRID CABLE - SEE SHEET C-4 FOR MECHANICAL DOWNTILT ADJUSTMENTS NOTES 1. ALL PROPOSED TOWER TOP EQUIPMENT TO BE PANTED TO MATCH EXISTING. PAIFL ANTENNA (TYPE�A) 7Q BE 7L ANTENNAS AOLNAS �T7f fl � (1/SECIOR-3 TOTAL) TOP OF EXISTING PANEL ANTENNAS 11 ' 11 � n EXISTING SOUTH ELEVATION C-3 SCALE 5' (22x34 SIZE) 1' 10' (11x17 SIZE) C1 PROPOSED SOUTH ELEVATION C-3 SCALE 1:: 5' (22x34 SIZE) 1' - 10' (11x17 SIZE) E ESS PRO M-) vwiZonN/ 125 W GEMINI DR TEMPE. AZ R5283 Tectonic' rzAcrltuaxmwla ta®naNAAzema. 0,. 3 23 ogr�M CaIr.a cse.eA ueal�aaA a. )) i w�ilz Iuznz ��` Ie�DD> e��isR www.tectonleengf—r ing—rzv-e 18664.TUC EL CONQUISTADORI I JMR I 0 9/21/18 FOR COMMENT 1 10/31/18 FOR PERMR RELEASED BY DATE I e � �PIVF IC4IF'L Po „ � 65322 0 ADRIAN - d gMASS!E ¢ es y" COPIES OF THIS DOCUMENT WRHOUT A FACSIMILE OF THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BWE OR RED INK OF THE PROFESSNINAL ENGINEER OR LAND SURVEYOR LL CON SHANOT BE SIDERED VALID COPIES 02 3 ORIGINAL SIZE IN INCHES SITE INFORMATION TUC EL CONQUISTADOR 10375 N LA CANADA DR ORO VALLEY, AZ 85737 PIMA COUNTY VZW LC: 157557 VZW PN: 20181799413 SHEET TYRE TOWER ELEVATION SHEET NUMBER C-3 UPGRADES INCLUDE: (3) REPLACEMENT PANEL ANTENNAS (TYPE 1) (6) NEW PANEL ANTENNAS (TYPE 1) (2 PER SECTOR) (6) NEW DUAL BAND RRUS (2 PER SECTOR) (6) NEW DUAL OIPLEXERS (1) NEW OVP-12 (1) NEW 6.12 HYBRID CABLE - SEE SHEET C-4 FOR MECHANICAL DOWNTILT ADJUSTMENTS EXISTING VETVON WIRELESS PANE_ ANTENNASTO BE TVPE N (1) PER SECTOR, (3) TOTAL SEGSO� 1y EXISTING DOGHOUSE EXISTING ANTENNA VIEW ETOSTING &V STEALTH CANISTER CAP AT TOP OF DOSTING TEP UIUM POLE TO BE REPLACED �1q � SECTOR a 7za (]:) EXISTING CONFIGURATION (ELEV = 73'-8") C-4 SCALE: 1' = 1'-0- �22.34 SIZE) 1/2' - 1'-0 (11x17 SIZE) g'-O'i 4'-6*t PROPOSED ANTENNA VERIZON WIRELESS O PANEL ANTENNA (TYPE 1 � (3/�--9 TOf y Nl 12 a IT PROPDUALOSED �S11 M1RF1ES5 PROPOSED VERIZON WIRELESS a r�' (2/SECTOR-0 TOTAL) PLATFORM MOUNT (SITE PRO ((�� RMQP-396 APPROVED EQUAL) LJ PROPOSED VERIZON WIRELESS OVP-12 (TYP OF 1) LJ tOR c ` EXISTING SF,G UTILITY POLE 6 G�� ryA6 �q SFC PROPOSED VERIZON WIRELESS DUAL DIPLDERR (2/SECTOR-0 TOTAL) (a:) PROPOSED CONFIGURATION (ELEV = 71'-91p) C-4 SCALE: 1/2- = 1'-0" (2204 SIZE) 1/4' = 1'-0' 1Ix17 SIZE) %wizon`' 126 W GEMINI DR TEMPE. AZ 85283 N Tectonic' P41[IICALlOLMlloet®mPPALwnu. T.v3 S eu[n 1 M-' McClintock Dr ( ) r.mw�nz B3TB2 Phone: (00) 6TB-6S�St h W—tactonicengineertng.com �n WORK ORDER NUMBERDRAWN B Y w 8664.TUC EL CONQUISTADORI JI MR I 4 0 9/21/18 FOR COMMENT 1 10/31/18 FOR PERMIT RELEASED 6Y 0.47E e 0 65322 0 „ U ADRIAN _- ofMASSIE r F+p res COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE OF THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VALID COPIES 0 1 2 3 ORIGINAL SIZE IN INCHES SITE INFORMATION TUC EL CONQUISTADOR 10375 N LA CANADA DR ORO VALLEY, AZ 85737 PIMA COUNTY VZW LC: 157557 VZW PN: 20181799413 SHEET TITLE ANTENNA CONFIGURATION SHEET NUMBER C-4 ANTENNA & CABLE SCHEDULE SECTOR ANTENNA POSITION STATUS FREQUENCY ANTENNA RAD FE ANTENNA AZIMUTH MECH DOWTN ELECTRICAL DOWN TILT DIPLEXER RRH OVP TMA COAX QTILUANTITY COAXIAL Dw1E ER HYBRID CABLES ALPHA 1 PROPOSED 5508 COW 71'-9' O' 0' 7 - - (1) OVP-12 - 2 7/8' 1 12�d4 ALPHA 2 PROPOSED 700/880A LTE/PCS 71'-9' O' R 2'/P/Z (2) DUAL 1 _ _ - ALPHA 3 PROPOSED 700/8.90A LTE/AWS 71'-9' 0' O 2/9'/i ALPHA 4 BETA 1 PROPOSED 850E COW 711-V 120' IT 2' - - - 2 7/8' BETA 2 PROPOSED 700/8504 LTE/PCS 71'-9' 120' 0' 8'/S/T (2) DUAL 1 - - - BETA 3 PROPOSED 700/&— LTE/AWS 71'-9' 120' O S/C/4 BETA 4 _ _ _ _ _ _ GAMMA 1 PROPOSED 8500 COMA 71'-9' 240' V 2' - - - 2 7/8' GAMMA 2 PROPOSED 700/&%A LTWPCS 711-9' 240' O' T/Y/Z (2) DUAL GAMMA 3 PROPOSED 700/— LTE/AWS 71'-9' 240' 0' 7/T/lr GNAW 4 _ CABLE SCHIDUIE NOTE (6) 7/8' COAX TO BE REMOVED, (6) 7/e' COAX TO REMAIN GENERAL NOTES 1. ALL WORK PRESENTED ON THESE DRAWINGS MUST BE COMPLETED BY THE CONTRACTOR UNLESS NOTED OTHERWISE. THE CONTRACTOR MUST HAVE CONSIDERABLE EXPERIENCE IN PERFORMANCE OF WORK SIMILAR TO THAT DESCRIBE HEREIN. BY ACCEPTANCE OF THIS ASSIGNMENT, THE CONTRACTOR IS ATTESTING THAT HE DOES HAVE SUFFICIENT EXPERIENCE AND ABILITY, THAT HE IS KNOWLEDGEABLE OF THE WORK TO BE PERFORMED AND THAT HE IS PROPERLY LICENSED AND PROPERLY REGISTERED TO DO THIS WORK IN THE STATE AND/OR COUNTY IN WHICH R IS TO BE PERFORMED. 2. ALL MATERIALS AND EQUIPMENT FURNISHED SHALL BE NEW AND OF GOOD OUALRY, FREE FROM FAULTS AND DEFEGIS AND IN CONFORMANCE WITH THE CONTRACT DOCUMENTS. ANY AND ALL SUBSTTRITIONS MUST BE PROPERLY APPROVED AND AUTHORIZED IN WRITING BY THE OWNER AND ENGINEER PRIOR TO INSTALLATION. THE CONTRACTOR SHALL FURNISH SATISFACTORY EVIDENCE AS TO THE KIND AND QUALITY OF THE MATERIALS AND EQUIPMENT BEING SUBSTITUTED. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INTLATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS W CONNECTION WITH THE WORK THE CONTRACTOR IS RESPONSIBLE FOR INSURING THAT THIS PROJECT AND RELATED WORK COMPUES WITH ALL APPUCABLE LOCAL, STATE, AND FEDERAL SAFETY CODES AND REGULATIONS GOVERNING THIS WORK. 4. ALL DIMENSIONS SHALL BE VERIFIED WITH THE PLANS (LATEST REVISION) PRIOR TO COMMENCING CONSTRUCTION. NOTIFY THE OWNER IMMEDIATELY IF DISCREPANCIES ARE DISCOVERED. 5. ALL MATERIALS AND WORKMANSHIP SHALL BE WARRANTED FOR ONE (1) YEAR FROM DATE OF ACCEPTANCE. II SCHEDULE NOTES 11 1. MARKING TAPE MUST BE APPLIED AT TOP OF FEED LINES AND AT BASE OF TOWER. 2. CHECK ALL ANTENNA INFO WITH VERIZON WIRELESS PRIOR TO CONSTRUCTION. 3. DESIGN REQUIREMENTS FOR ANTENNA, SUPPORTING STRUCTURES EQUIPMENT CABINETS, AND PPC CABINETS PER BUILDING CODE (LATEST EDITION) WIND SPEED REQUIREMENTS AS LISTED ON SHEET T-1. 4. HYBRIFLEX CABLE IS 1.54', RET CABLE IS 0.315' 5. CAP AND WEATHERPROOF UNUSED PORTS AND UNES 7.6' FRONT SIDE 2.0• TOP r7-� EXISTING ANTENNA DETAIL C-5 SCALE: 1/2' a 1'-0• (22x.T4 SIZE) i/4:. 1'-0' (1107 SIZE) 10.7' FRONT SIDE 15.5' I. TOP n PROPOSEDANTENNA DETAIL C-5 SCALE. 1%4' 1'-0' (22.34 SIZE) 11x,7 SIZE) ro .—i r5 -,ti PROPOSED VERRON WMIFIESS IQtUS WE MOUNT PROFlE CLAMP ASSEMBLY ER ICSSON UUNINAA:IUN IU UIIULL LIIISIING ANTENNA MOUNTING PIPE UNLESS FIELD CONDITIONS WARRANT USE OF NEW VERTICAL MOUNTING PIPE. �RRUS RAIL MOUNT DETAIL C-5 SCALE. NIS RRUS OVERVIEW TYPE LTE/700 AWS/21 DO PCS/1900 AWS/2100 HAND B13 I B5 82/B25 84/B66 MODEL DUAL LOW BAWD RRUS DUAL HIGH BAND RRUS OUTPUT 4x4O/2x60 4.40 HEIGHT (H) - IN 18.0 18.0 WIDTH (W) - IN 13.2 13.2 DEPTH (D) - IN 9.4 11.3 W.— - LBS 70 75 'WITH MOUNT n DUAL BAND RRUS DETAIL C-5 SCALE: NTS r6.7611 n PROPOSED DIPLEXER DETAIL C-5 SCALE' NTS WEIGHT: 616Kg vwizon✓ 126 W GEMINI DR TEMPE, AZ 85283 Tectonic' R. �ucnAuaounweaevnesuxvVl L i son r No,e M— —cen.4e.lw� et(( ) www.tectonicengin"ring.COM N n 18664.TUC EL CONQUISTADOR] I JMR I 0 9/21/18 FOR COMMENT 1 10/31/18 FOR PERMIT RELEASED BY DATE 0 ¢ssb u AFICATF% a- 65322 0 ADRIAN m e MASSIE es. CONES OF THIS DOCUMENT WIIIIOUT A FACSIMILE OF THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BWE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR SINLL NOT BE CONSIDERED VALID COPIES. D 1 2 3 ORIGINAL SIZE IN INCHES SATE INFORMATION TUC EL CONQUISTADOR 10375 N LA CANADA DR ORO VALLEY, AZ 85737 PIMA COUNTY VZW LC: 157557 VZW PN: 20181799413 SHEET TITLE EQUIPMENT SCHEDULE & EQUIPMENT DETAILS SHEET NUMBER C-5 n15.73' V 00 10.28' PAN WIEW ROPOSED VERIZON / WIRELESS OVP ISTINC STANDOFF E CLAMP (2) OVP MOUNTING DETAIL C-G SCALE: NTS PM13lSf M34 PART NO. PART DESCROPTLON LOWN LWTWT. NET Y/T, �J 1 3 XiWRN RING NONNT W IXT MAI 306.43 2 9 GSRR•24 WX24"TrIR6ADm PI10 HOG 0.40 339 \ 2 9 Gs" ST" x ae" TXREAO® ROD ) 0.40 339 3 3 X•SV196 LOW PROPIIE PLATFORM DDRUM =10 6.16.31 i 4 12 ASII A Wr X 2-3W HDG AM HFx WILT 2.73 0.3E 427 6 12 ASSFW 3 "HDG A323 RATWA 0.03 0.41 6 30 GSBLW e"WGLW(WAF6R 0.03 0.7E 7 30 ABBNur E "NOG A325 HEX NUT 0.13 3.00 2 e 3 P3140 SVr X LW SON 40 GALVAM= PtK 15D4W in 9490 294.a0 6 9 30 XUBL06 ur X 3-wr X 6• X 3" U80LT (Hoa) 0.25 7.71 10 96 1 G177W HOG IUTWA91Et 00.T 327 7 xi 11 96 G12LW iR'HDG IDDGYA9EIl 0.01 IJ7 DETAIL 8 u 981 GLmvr "HDGHFAVY2HFVMUf 107 6.6E 4 13 9 X-SP219 SNlALl 9)PWRT GA RATE UNlle 66L 1 30 14 1 18 1 %LI21 B1 1 %4U2"XTIYsxT 0.2E 1 4.63 c S 13 9 B PMOBU MOlMTZC POPE C 0 B i I-� PDETAILA 9 3 xi 10 X2 xi l X2 xiA DETAIL C D. WRTIM MOMM PV S A3$96LY ND. •A- I PARHET vNTAL WEIGHT 63 20.IS 181.62 149aJ7 7i Z3.97 207.63 1A0.18 RMOP- 81' 26.91 1 242.19153/99 P246 96" 70.7E i v M SSB0.59 Pa126 26• 40.7E 360.74 1679.SO TOLERANCE NOTE Dlernox m TOURANOBE ON lllld EIGM. UNLESS OTHBAWMENOTEO ARE m LOWPROFlLECOAACATNNI PLATFORM I 0 Icy BAWED,AWDOAOAN00AB CUTEOOE-)-O.COO FOR 9 ANTENNA3.WIIRt,L6"FACE WNOTjj_ _ RO ♦rr"t oxn.a ----O0.ILLGO ANDOA9piTH0.P6jYQ.030� NO COWNOOFIi0t8- - FOR12-36'DIAMETERPOLES BA9Mt0UT[D068 AMD XOlAT1 (t0.010'T-NOOONINO WXOIF9 AxAtw°rNTmBr Dxw.n B OT IRAv2 V(20 ALL OINFR MAOXx11N0 (: D.0]0'1 ALLOTNERAS>f/1®LY (f O.oen ln SEEASSEMBLYNO. A 10 ANIENR4 HOUNT1rvG P[Pes C6X /72G1e CEKY 1/t B12012 Ber CUSTOMER PROPRIARY NDTB 2 oNorRensAx+s cPo eY� p4TE zm xo. RMQP-3XX FI REVS xuTprc BMC 1/2312D12 x %mrx ow.) X TOLERANCE NOTE oAeclarrox TOUMM1409SON MMENSION3. UNLESS OTNERW18E NOTFDARE LOW p.....O--LOCATION PLATFORM SITE BAWE0, 6NBARED AN00AB CUT®OE6l2 O.O407 wErwO°"�1T.s r N. {".O5 FORS ANTENNAS WITH 12 E" FACE MOTH PR ORILIEDANDOAe WfMOLFD (x O.030•j•NO CDNB3G OF HDlE9 t4166T6STM{ nix WI RCUTEDGPB AND XOlFE O°OA10'7 N0 CONING OP H0113 FOR1Y-36'OIAMETER POLES .XInuNYa�B 'n BENDBAREA112 DEGREE-ALLOTNER MACNWINOf20.030ry ALLOTHERABBEMBLY(l CD60") duwx eY aro nn OtAw°ac V5n9E A AODEo tD 6•AN1Exw,MwR+Tv+G Pees t cW 1/19/2012 -b CUSTOMER «a SEE ASSEMBLY NO."A" F DPrRIPNCN OP REWSII%K D BYi DATE PROPRIETARY NOTE cHwx�n . xo. w � REtnsaN InsrTar I BMC 1/2312D12 RMQP-3XX (2) PROPOSED SITE PRO RMQP-396 DETAIL C-6 SCALE NTS %WIZon,-/ 126 W GEMINI Oft TEMPE, AZ 85283 a a W Tectonic' ru[OGLL4ol4rIBrM. ISOnOYL U. W Twbnb C"IIDnxNq CawIbPN P.Gro„ >P` Scxtn MOCllntock Or. 409 P1wnr. 2R-axx Temp", AZ tect 0g. o 1 N www.tectonicengtneering.com In N WORK ORDER NUMBER DRAWN BY w 0 664.TUC EL CONQUISTADOR I JMR Q 0 9/21/18 FOR COMMENT 1 10/31/18 FOR PERMIT RELEASED BY DATE n tSXF ICA 7F' a n oe 65322 o e ADRIAN _- Q MASSIE " es. F+p �s I', 0 PAGE BP NOT TO BE SUBMITTED FOR REFERENCE ONLY DIPLEXERS 17'-4' (INTERIOR) REMOVE 12) REMOVE EKISTING AND BBLI AND REPLACE WITH lEIII!s ERICSSON DWSHELVE ML 1() FOR 700/&W&AWAWS 12 ON NEVI 19' RACK NEW 0 AWS/700 MOD CELL FIBER BBUU 850B COMA (I) SHELTER INTERIOR PLAN SHLTR SCALE 3/4' a 1'-0- (22.34 SIZE) 3/8' - 1'-0' (11.17 SIZE) EXISTING COAX ENTRY PORT POB I BATTERIES A/C DISTRIBUTION BOX COMMENT MODIFICARON TO AN EXISTING VERIZON WIRELESS UNMANNED TELECOMMUNICATIONS FACILITY TO CONSIST OF THE FOLLOWING: 1. REMOVE (1) EXISDNG BBU 2. REMOVE (3) EXISDNG PANEL ANTENNAS 3. REMOVE (1) ETOSnNG AWS TRDU 4. REMOVE (1) EXISTING 700 TRDU S. REMOVE (3) EXISDNG TMAS FROM TOWER 6. REMOVE (3) OUSTING ATEL DPX-22 DIPLEXERS FROM SHELTER E M 7. ROVE (3) EXISRNG ATEL DPX-076 DIPLEXERS FROM SHELTER 8. REMOVE (6) EXISDNG RFS FDL85002 DIPLEXERS FROM SHELTER 9. INSTALL (9) NEW PANEL ANTENNAS (REQUIRES NEW PLATFORM) 10. INSTALL (3) NEW ERICSSON RRUS-4N9 B13/B5 ON TOWER BEHIND ANTENNA 2 11. INSTALL (3) NEW ERICSSON RRUS-8843 82/B66A ON TOWER BEHIND ANTENNA 3 12. INSTAL (5) NEW COMMSCOPE CBC78 DUAL DIPLEXERS ON TOWER 13. INSTALL (1� NEW ERICSSON BB-6630 14. INSTALL (1 NEW 602 HYBRIFLEK HYBRID CABLE 15. INSTALL (2) NEW OVP-SHELF IN SHELTER vwizonJ 126 W GEMINI DR TEMPE. AZ 85283 TectoniP T..dM. o.�... ►S s�R. 4ov Pne.e .e¢JJ .-I www.tectonlcanginserinq.com in WORK ORDER NUMBER DRAWN 8664.TUC EL CONQUISTADOR JMR z NO. DATE ISSUE 0 9/21/18 FOR COMMENT 1 10/31/18 FOR PERMIT Nt1tA R:V t1Y DATE ¢sw `o pt1F ICAr e ¢ 65322 0 % a ADRIAN m a MASSIE`" COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE OF THE SIGNATURE AND AN ORIGINAL EMBOSSm SEAL OR ORIGNAL STAMP IN BWE OR RED INK OF THE PROFESSION4l ENGNEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VAUD COPIES, 0 1 2 } ORIGINAL S1ZE IN INCHES SITE INFORMATION TUC EL CONQUISTADOR 10375 N LA CANADA DR ORO VALLEY, AZ 85737 PIMA COUNTY VZW LC: 157557 VZW PN: 20181799413 SHEET THE SHELTER PLAN SHEET NUMBER SHLTR 3 oQO.4 ,LIEY .qR/2029 �D�/NDED 19�� Town of Oro Valley Community and Economic Development Department February 6, 2019 Carmelina Scigliano 3923 S. McClintock Drive, Suite 409 Tempe, AZ 85285 Cscigliano(aD-tectonicengineering.com Re: Tier II Communication Facility Near the SWC of Lambert Lane and La Canada Drive Action Letter, OV1802935 Dear Ms. Scigliano, During their regularly scheduled meeting on February 5, 2019, the Planning and Zoning Commission approved the proposed modifications to an existing Tier II Communication Facility, located near the southwest corner of Lambert Lane and La Canada Drive. The approved modifications do not require building permits. However, please proceed with acquiring a right-of-way permit for installation. If you have any questions, please do not hesitate to contact me. Best regards, i� '4" Milini Simms Senior Planner 520.229.4836 msimms@orovalleyaz.gov