HomeMy WebLinkAboutOV1601138CLIENT: venzonv TUC VENTANA-2 SC 2150 E. TANGERINE ROAD VICINITY MAP z �O o zz h�foso SPNGER�NE R� SITE o R � m Z J n PALISADES RD I NORTH DRIVING DIRECTIONS SUMMARY: FROM THE VER'ZON OFFICES IN TEVPE: TAKE 1-10 SO'JTh TO TUCSON. _AK- EX,T 240, TURN LEFT ONTO W. TANGERINE RD. TURN RGHT ONTO N. INNOVATION MARHET DR. SITE IS ON TIIE LEFT ON THE ROOF TOP OF WAL MART BUILDING. GENERAL NOTES THE ARCHITECTS/ENGINEERS HAVF MADE EVERY EFFORT AS SET FORTH IN THE CONSTRUCTION DRAWINGS, CONTRACT DOCLVENTS AND THE CCVPLLTE SCOPE OF WORK. CONTRACTORS BIDDNG TH- JOB ARE NEVERTHELESS CAUTIONED TrAT MINOR OMISSIONS OR ERRORS IN THE DRAWNCS AND SPECIFICATIONS SHALL NOT EXCUSE SAD CONTRACTOR FROM CCVPLELNG THE PROJECT AND IVPRCVLMLNTS IN ACCORDANCE WITH THE n\iENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR TnE RESrO\'SBLITY OF NOIFYItiG (IN W'RITNG) THE ARCHITECT/ENGINEER 0: ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF THE CONTRACTOR'S PROPOSAL. IN THE EVENT 0, D SCREPAINC LS TnL CONTRACTOR SHALL PR CE TLE MORE COSTLY OR EXTENSIVE WORK UNLESS OTHERWISE DIRECTED. ORO VALLEY, AZ 85755 AP N NO. 220-04-3240 Two WO'K',rg days before you dig, CALI FOR THE BLUE STAKE! 1 (602) 263-1100 or 1 (800) STAKE -IT (782-5348) (OUTSIDE MARiCOPA COUNTY) SITE LOCATION INFORMATION PROJECT TEAM STE NAME: TUC_VENTANA_2_SC CLIENT: VER170\ WIRELESS 126 WEST GLV N: DRNE SITE ADDRESS: 2150 E. TAN'CERINE ROAD 7EM7)E, ARIZONA 85283 ORO VALLEY, AZ 85755 CONSTRUCTION MANAGER: DAMON GAUTHIER APN N'dVBFR: 220-04-3240 M BI : (602) 291-b983 CENTER OF LAT.TUDE: 32' 25' 33.7" N (NAD 83) R ENGINEER: SYED NAQV BUiLO''NG LONGTUDL: 110' 56' 27.4" W (NAD 83) COORDINATES: E'_EVATO\: REAL ESTATE: JAM SON TYLER 2,671.0' (AVSL) (NAVJ 88) MOBI _�: (480) 777-4336 SECTOR "A" LATITUDE 32' 25' 32.0" N (NAD 83) COORDINATES: LONGTJDE: 110' 56' 30.4" W (NAD 83) REA_ LS1AT= INS'TE INC. CONSULTANT: 2035 E. GO\DD_A LN. SECTOR "B" LATITUDE: 32' 25' 31.8" N (NAD 83) CiLBLRT, AZ 85234 COORDINATES: LCNGITJDC 110' S6' 24.4" W (NAD 83) CONTACT: CHRIST\E TUCKER MOBILE: (480) 586-5180 CURRENT ZONAG: TBD TUCKER@\STE-INC.COV A&E DESIGN SI,NO DES ON A=PLICA\T: VERIZO\ WIRELESS MANAGEMENT 16616 EAST PALISADES BLVD, SJ'TE 102 126 WEST GEVAI DR. PROFESSIONAL: FOUNTAIN HILLS, APoZONA 85268 TEMPE, AZ 85283 CO\TACT: CHRIS M. SIND, NBA, VSTL, PIMP CO\TACT: DAMON GAUTHER MOBILE: (602) 672-4311 PHONE: (602) 291-5983 FAX: (480) 836-1004 PROPERTY OWNER: VPGVN LLC CIVIL ENGINEERING ISE INC. CONSULTANT: PO BOX 80039 2425 E CAV =LBACK RD STE 750 - PHOENIX, ARIZONA 85076 PHOENX AZ 85016-4261 CONTACT: GLEN L. HUNT III, PE PHONE: (602) 403-8614 EE CO\S'JLTANT: EE LLC CO\TACL LOREN PRIEST CODE COMPLIANCE M°BI`E: (303) 746-1169 I _ A_L WORK AND MATERALS SHALL 3- PERFORMED AND INSTALLED IN ACCORDANCL WTH ThE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCA'_ ACCESSIBILITY DISCLAIMER GOVERNNG AUTHORITIES. NOTHAO IN THESE PLANS IS TO BE CONSTRUED TO PERVIT WORK NOT CONFORMING TO THESE CODES. 2C'2 INTERNATIONAL BUILDING CODE (IBC) THE PROPOSED PROJECT IS AN UNOCCUPIFD TELECOMVUN,CATIONS 2011 NAT CAAL ELECTRICAL CODE (NEC) FACiI'Y AND IS NOT TO BE ACCESSED BY THE GENERAL ?'JBIJC. ANSI/LIA-222—G STRUCTURAL STEEL STANDARDS FOR STEEL THIS FACILITY IS FXFVPT FROM DISA9.ED ACCESS REOJIREVENTS -QU ANTENNA TOWERS A%,' SJPPORTNC STRUC`LI STANDARD PER IBC 1103.2 9 LISTED AS AN PVLNT SPACE. LOCAL BUILDING CODES) CITY A\D/OR COJ\TY ORDINANCES JURISDICTION: TOWN OF ORO VALLEY SHEET INDEX SHEET NO. SHEET DESCRIPTION T-1 TITLE SHEET GN-1 GENERAL NOTES GN-2 GENERAL NOTES S-1 SITE SURVEY LS-2 SITE SURVEY A-1 OVERALL SITE PLAN A EN'LARGi.D S'TE PLAN A-3 ELEVATION A-4 CONSTRUCTION DEIA:LS E-1 ELECTR�CA_ NOTS E-2 ELECTRICAL NOTES E-3 POWER PLAN E-4 0\ELiNF D AGRAM & PANEL SC-EDJ.E G-1 GROJND NG PLAN G-2 GROUNDING DETAILS ATTACHMENT; STRUCTURAL ANALYSIS & EVALUATION REPORT PROJECT DESCRIPTION T-E PROJECT CONSISTS OF THE INSTA'_LAT',0\ OF (2) NFW ANTENNAS TO A\ EkSTNG BJILDING AND BEHIND REP SCREENS. IN ADDITION, INSTALLATON 07 (1) NEW EQ'JI'MLNT CAB.NLT ON (1) NEW NON-PLNETRATiO\ PLATFORM ON EXISTING BUILDING ROOF TOP AND (2) NEW NO\-PENTRATRALO\ MOUNT 10 SPPORI (2) NEW RRHs. T-JS PROJECT DOES NO- INCLUDE WATER OR SEWER. T-IS PROJECT INCL'JDES PERMANENT TELEPHOVE AND E�ECTR'CA. CO\NECTIONS. DEVELOPMENT AND CONSTRUCTION OF TH S PROJECT WILL COMPLY WITH ALL APPLICABLE CODES AND OiR°'AANCES. vefton,/ 126 WEST GEMINI DRIVE TEMPI, ARIZONA 85293 PHONE: 480.752.7238 DESIGN MANAGEMENT PROFESSIONAL' ®SiinoDesign 16616 EAST PALISADES BOULEVARD UNIT /102 FOUNTAIN HILLS, ARIZONA 85268 PHONE 480.836.1701 FAX: 480.836.1004 WWW.SIINODESIGN.COM ENGINEERING CONSULTANT: DRAWING APPROVALS (SGNATURES) 51E ACQU.STOS/rROPERTY CONSTRUCTION MANAGER VER'ZON WRELESS RF ENGINEER LANDLORD A=�ROVAL DRAWN BY: JNGO CHECKED BY: CMS SC:LEDj_E 0- REV'SO\S NO DATE DESCRIPTION BY 3 2 8/08/16 CITY CCVM-NTS CVS 1 4/13/s6 COMMENTS CNS 0 4/05/16 1 PRELIM C0 CNS SITE NAME: TUC_VENTANA 2 SC STE ADDRESS: 2150 E. TANGERINE ROAD NO VA.LEY, AZ 85755 SEAL SHEET TTLE: TITLE SHEET SHEE? NUM6ER: T-1 CLIENT: GENERAL NOTES: 1. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR. AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE PROJECT AS DESCRIBED IN THE DRAWINGS AND OWNER'S PROJECT MANUAL. 2. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE NEW PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION/CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. 1. GENERAL CONTRACTOR IS TO COORDINATE ALL POWER INSTALLATION WITH POWER COMPANY AS REQUIRED. CONTRACTOR TO REPORT POWER INSTALLATION COORDINATION SOLUTION(S) TO NETWORK CARRIER REPRESENTATIVE, PROJECT CONSTRUCTION MANAGER AND ARCHITECT. 2. ANY SUBSTITUTIONS OF MATERIALS AND/OR EQUIPMENT, MUST BE APPROVED BY (COMPANY) CONSTRUCTION MANAGER. 3. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA FRAMES WHERE PENETRATION OF EXISTING ROOFING MATERIALS OCCUR, THE GENERAL CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER AND BUILDING ROOFING CONTRACTOR OF RECORD FOR INSTALLATION, PATCH, REPAIR OR ANY AUGMENTATION TO THE ROOF, AND HAVE THE WORK GUARANTEED UNDER THE ROOFING CONTRACTOR'S WARRANTY FOR MOISTURE PENETRATION OR AND OTHER FUTURE BREACH OF ROOFING INTEGRITY. 4. CONTRACTOR SHALL SUPERVISE AND DIRECT ALL WORK, AND PROVIDE CONTINUOUS SUPERVISION WHILE ANY SUBCONTRACTORS OR WORKMEN ARE ON THE JOB SITE. 3. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE 5 CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM 6' COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECT/ENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL 7. PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. 4. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 5. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 6. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 7. GENERAL CONTRACTOR SHALL PROVIDE, AT THE PROJECT SITE, A FULL SET OF CONSTRUCTION DOCUMENTS UPDATED WITH THE LATEST REVISIONS AND ADDENDA OR CLARIFICATIONS FOR USE BY ALL PERSONNEL INVOLVED WITH THE PROJECT. THIS SET IS A VALID CONTRACT DOCUMENT ONLY IF THE TITLE SHEET IS STAMPED "FOR CONSTRUCTION" AND EACH SUCCESSIVE SHEET BEARS THE ARCHITECT'S SIGNED WET STAMP. 8. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 9. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE. 10. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. 11. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION. UPON COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. 12. CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, AND RUBBISH. CONTRACTOR SHALL REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OR PREMISES. SITE SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. 13. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 14. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS. 15. THE CONTRACTOR SHALL PROVIDE COMPANY WITH. PROPER INSURANCE CERTIFICATES NAMING (COMPANY). AS ADDITIONAL INSURED, AND (COMPANY) PROOF OF LICENSE(S) AND PE & PD INSURANCE. 16. CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND COORDINATING ALL INSPECTIONS. 17. CAUTION! CALL BEFORE YOU DIG! BURIED UTILITIES EXIST IN THE AREA AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE ONE -CALL UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION. 1-800-332-2344. 18. CONTRACTOR TO DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS AND SUBMIT TO (COMPANY) ALONG WITH REDLINED CONSTRUCTION SET. 19. CONTRACTOR TO DOCUMENT ALL CHANGES MADE IN THE FIELD BY MARKING UP (REDLINING) THE APPROVED CONSTRUCTION SET AND SUBMITTING THE REDLINED SET TO (COMPANY) REPRESENTATIVE UPON COMPLETION. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES OF THE WORK UNDER THE CONTRACT. CONTRACTOR SHALL PROTECT ALL EXISTING IMPROVEMENTS AND FINISHES THAT ARE TO REMAIN. CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY OCCUR DURING CONSTRUCTION TO SATISFACTION OF VERIZON WIRELESS REPRESENTATIVE. CONTRACTOR SHALL KEEP THE CONSTRUCTION SITE CLEAN, HAZARD FREE AND DISPOSE OF ALL DIRT, DEBRIS DURING CONSTRUCTION. LEAVE PREMISES IN A VACUUM AND BROOM CLEAN CONDITION, FREE FROM PAINT SPOTS, DUST, SMUDGES OF ANY NATURE AND IN WORKING ORDER UNTIL ACCEPTANCE BY VERIZON WIRELESS AND PROPERTY OWNER. 8. IN THE CASE OF ROOFTOP SOLUTIONS WITH THE INSTALLATION OF ANTENNAS WITHIN CONCEALED (SHROUDED) SUPPORT FRAMES OR TRIPODS, THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE FRP DESIGNER/FABRICATOR TO ENSURE THAT THE FINAL FRP SHROUD IS SIMULATING (IN APPEARANCE) DESIGNATED EXISTING EXTERIOR BUILDING FACADE MATERIALS, TEXTURES, AND COLORS. THE CONTRACTOR SHALL FURTHERMORE ENSURE THE USE OF COUNTERSUNK FASTENERS IN ALL FRP CONSTRUCTION. WHEN PHOTOSIMULATIONS ARE PROVIDED, THE CONTRACTOR SHALL ENSURE THAT FINAL CONSTRUCTION REPRESENTS WHAT IS INDICATED IN PHOTOSIMULATION. SHOP DRAWINGS SHALL BE PROVIDED TO THE GENERAL CONTRACTOR, CONSTRUCTION COORDINATOR, AND ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION. 9. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA FRAMES WHERE ANCHORING TO A CONCRETE ROOF SLAB IS REQUIRED, CONTRACTORS SHALL CONFIRM (PRIOR TO SUBMITTING BID) WITH CONSULTING CONSTRUCTION COORDINATOR AND ARCHITECT THE PRESENCE OF POST TENSION TENDONS WITHIN THE ROOF SLAB - RESULTING FROM AN UNDOCUMENTED DESIGN CHANGE IN THE EXISTING BUILDING "AS -BUILT DRAWING SET" - HAVING INDICATED AN ORIGINAL DESIGN SOLUTION OF REINFORCED CONCRETE W/ EMBEDDED STEEL REPAR. IN THE EVENT POST TENSION SLAB SOLUTION IS PRESENT, CONTRACTOR SHALL INCLUDE PROVISIONS FOR X-RAY PROCEDURES (INCLUDED IN BID) FOR ALL PENETRATION AREAS WHERE ANCHORING OCCURS. 10. GENERAL & SUB CONTRACTORS SHALL USE STAINLESS STEEL METAL LOCKING TIES FOR ALL CABLE TRAY TIE DOWNS AND ALL OTHER GENERAL TIE DOWNS (WHERE APPLICABLE). PLASTIC ZIP TIES SHALL NOT BE PERMITTED FOR USE ON VERIZON WIRELESS PROJECTS. RECOMMENDED MANUFACTURE SHALL BE: PANDUIT CORP. METAL LOCKING TIES MODEL NO. MLT4S-CP UNDER SERIES-304 (OR EQUAL). PANDUIT PRODUCT DISTRIBUTED BY TRIARC OF TACOMA, WA. 11. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR RED -LINING THE CONSTRUCTION PLANS TO ILLUSTRATE THE AS -BUILT CONDITION OF THE SITE. FOLLOWING THE FINAL INSPECTION BY VERIZON WIRELESS, THE CONTRACTOR SHALL PROVIDE VERIZON WIRELESS WITH ONE (1) COPY OF ALL RED -LINED DRAWINGS. NOTE ALL OF THE FOLLOWING: 11.a. MODIFICATIONS OF ANY SCHEDULE 11.b. MODIFICATION OF ANY DIAGRAM 11.c. SUBSTITUTIONS AND/OR MODEL NUMBERS OF EQUIPMENT 12. VERIFY ALL FINAL EQUIPMENT WITH VERIZON WIRELESS REPRESENTATIVE. ALL TELEPHONE/RADIO EQUIPMENT LAYOUT, SPECIFICATIONS, PERFORMANCE INSTALLATION AND THEIR FINAL LOCATION ARE TO BE APPROVED BY VERIZON WIRELESS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH THE WORK AND CLEARANCES REQUIRED BY OTHERS RELATED TO SAID INSTALLATIONS. STANDARD CIVIL NOTES: 1. ALL SITE WORK SHALL BE AS INDICATED ON THE DRAWINGS AND STIPULATED IN THE SPECIFICATIONS PROJECT SUMMARY. 2. RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 3. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. 4. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO THE CRUSHED STONE APPLICATION. 5. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY ENGINEERS. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR PIER DRILLING AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. 6. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND SHALL BE CAPPED, 20. FOR COLLOCATION SITES: CONTACT TOWER OWNER REPRESENTATIVE FOR PARTICIPATION IN PLUGGED OR OTHERWISE DISCONNECTED AT POINTS WHICH WILL NOT INTERFERE WITH THE BID WALK. EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF THE ENGINEERS. 7. THE AREAS OF THE CUSTOMER'S PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE BUILDING, DRIVEWAY OR CRUSHED STONE, SHALL BE GRADED TO A UNIFORM SLOPE, FERTILIZED, SEEDED, AND COVERED WITH MULCH AS SPECIFIED IN THE SPECIFICATION LANDSCAPE WORK. GENERAL CONCRETE NOTES: 1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI-318. 2. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH CHAPTER 19 OF THE CURRENT BUILDING CODE. STRENGTHS AT 28 DAYS AND MIX CRITERIA SHALL BE AS FOLLOWS. TYPE OF CONSTRUCTION 28 DAY STRENGTHS (f'c) W/C MINIMUM CEMENT CONTENT A. SLABS ON GRADE RATIO PER CUBIC YARD TOPPING SLABS 2,400 PSI CONCRETE PIERS 5.45 5 1 2 SACKS / B. ALL STRUCTURAL CONCRETE 4,000 PSI EXCEPT WALLS <-.45 6 1/2 SACKS C. CONCRETE WALLS 4,000 PSI 5.45 6 1/2 SACKS 3. CEMENT SHALL BE ASTM C150, PORTLAND CEMENT TYPE II U.N.O. 4. THE GENERAL CONTRACTOR SHALL SUPERVISE AND BE RESPONSIBLE FOR THE METHODS AND PROCEDURES OF CONCRETE PLACEMENT. 5. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO ASTM C260, C494, C618, C989 AND C1017. TOTAL AIR CONTENT SHALL BE IN ACCORDANCE WITH TABLE 1904.2.1 OF THE CURRENT BUILDING CODE. 6. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1), GRADE 60, fy--60,000 PSI. EXCEPTIONS: ANY BARS SPECIFICALLY SO NOTED ON THE DRAWINGS SHALL BE GRADE 40, fy--40,000 PSI. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615(S1) MAY BE WELDED ONLY IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN A.W.S. D14 ARE SUBMITTED. 7. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCE WITH AC1 315 AND 318. LAP ALL CONTINUOUS REINFORCEMENT AT LEAST 30 BAR DIAMETERS OR A MINIMUM OF 2'-0". PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS AT LEAST 30 BAR DIAMETERS OR A MINIMUM OF 2'-0 LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. 8. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. 9. SPIRAL REINFORCEMENT SHALL BE PLAIN WIRE CONFORMING TO ASTM A615, GRADE 60, fy--60,000 PSI. 10. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE CONSULTANT. 11. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: FOOTINGS AND OTHER UNFORMED SURFACES, EARTH FACE 3" FORMED SURFACES EXPOSED (#6 BARS OR LARGER) 2" TO EARTH OR WEATHER (#5 BARS OR SMALLER) 1 1/2" SLABS AND WALLS (INTERIOR FACE) 3/4" 12. BARS SHALL BE SUPPORTED ON CHAIRS OR DOBIE BRICKS. 13. ANCHOR BOLTS TO CONFORM TO ASTM A307. 14. NON -SHRINK GROUT SHALL BE FURNISHED BY AN APPROVED MANUFACTURER AND SHALL BE MIXED AND PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED RECOMMENDATIONS. GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE MATERIAL ON WHICH IT IS PLACED (3,000 PSI MINIMUM). 15. ALL EXPANSION ANCHORS TO BE HILTI BRAND. ADHESIVE ANCHORS REQUIRE TESTING TO CONFIRM CAPACITY UNLESS WAIVED BY ENGINEER. STRUCTURAL STEEL NOTES: 1. SHOP DRAWINGS FOR STRUCTURAL STEEL SHALL BE SUBMITTED TO THE CONSULTANT FOR REVIEW PRIOR TO FABRICATION. verizo I 126 WEST GEMINI DRIVE TEMPE. ARIZONA 85293 PHONE: 480.752.7238 ISiinoDesign 16616 EAST PALISADES BOULEVARD UNIT #102 FOUNTAIN HILLS. ARIZONA 85268 PHONE: 480.836.1701 FAX: 480.836.1004 WWW.SIINODESIGN.COM ENGINEERING CONSULTANT: DRAWING APPROVALS (S'.CNA'JRES) STE ACQDIST.ON/PROPERTY CONSTRJCTON MANAGER VERZON WRE_ESS R� ENO.NEER LANDLORD APPROVAL DRAWN BY: „NOO CHECKED BY: CNS SCHEDULE 07 REVISIONS NOI DATE D:SCRPT,Ot EY 2 8/08/16 CITY COMMENTS CNS 1 a/13/16 COMM_'I'S CNS 0 4/C5/16 PRLLIM CD CMS SITE NAME: TUC VENTANA 2 SC SE A..: STE ADDRESS: 2150 E. TANC=R.KE ROAD ORO VA -LEY, AZ 85755 2. STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION (INCLUDING FIELD WELDING, HIGH STRENGTH FIELD BOLTING, EXPANSION BOLTS, AND THREADED EXPANSION ANCHORS) SHALL BE BASED ON THE A.I.S.C. "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" LATEST EDITION. SUPERVISION SHALL BE IN ACCORDANCE WITH CURRENT BUILDING CODE, BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE S,EET T,TLE CONSULTANT. THE CONSULTANT SHALL BE FURNISHED WITH A COPY OF ALL INSPECTION REPORTS AND TEST RESULTS. GENERAL NOTES 3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: SHEET NUMBER: G N-1 STRUCTURAL STEEL NOTES: 12. COMPLETE THIS WORK IN A TIMELY FASHION, WITHOUT INTERFERING WITH, OR DELAYING THE WORK OF OTHER TRADES. CUENT: 1. SHOP DRAWINGS FOR STRUCTURAL STEEL SHALL BE SUBMITTED TO THE CONSULTANT FOR REVIEW PRIOR TO FABRICATION. A. COMPLETE ALL WORK ACCORDING TO APPLICABLE CODES AND REGULATIONS. 2. STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION (INCLUDING FIELD WELDING, HIGH B. COMPLETE ALL WORK ACCORDING TO THE STANDARDS AND SPECIFICATIONS OF THE STRENGTH FIELD BOLTING, EXPANSION BOLTS, AND THREADED EXPANSION ANCHORS) SHALL MASONRY INSTITUTE OF AMERICA. BE BASED ON THE A.I.S.C. "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF C. MASONRY ACCESSORIES AND REINFORCING -- INSTALLATION STRUCTURAL STEEL FOR BUILDINGS" LATEST EDITION. SUPERVISION SHALL BE IN D. INSTALL METAL TIES FOR BONDING AS PER DETAILS AND REFERENCED TRADE STANDARDS. ACCORDANCE WITH CURRENT BUILDING CODE, BY A QUALIFIED TESTING AGENCY DESIGNATED ASSURE COMPLIANCE IN TYPES, SIZES, SPACING, DEPTH OF ANCHORING AND CORROSION BY THE CONSULTANT. THE CONSULTANT SHALL BE FURNISHED WITH A COPY OF ALL RESISTANCE. INSPECTION REPORTS AND TEST RESULTS. E. INSTALL REINFORCING AS PER DETAILS AND REFERENCED TRADE STANDARDS. 3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: TYPE OF MEMBER A. PLATES, SHAPES, ANGLES, AND RODS ASTM A36, Fy 36 KSI B. SPECIAL SHAPES AND PLATES ASTM A572, Fy 50 KSI C. PIPE COLUMNS ASTM A53, Fy 35 KSI D. STRUCTURAL TUBING ASTM A500, Fy 46 KSI E. ANCHOR BOLTS ASTM A307 F. CONNECTION BOLTS ASTM A325 TWIST -OFF -TYPE 4. ALL MATERIAL TO BE HOT DIPPED GALVANIZED AFTER FABRICATION PER A123/A123M-00. 5. ALL WELDING SHALL BE IN CONFORMANCE WITH A.I.S.C. AND AWS STANDARDS AND SHALL BE PERFORMED BY W.A.B.O. CERTIFIED WELDERS USING E70 XX ELECTRODES. ONLY PREQUALIFIED WELDS (AS DEFINED BY AWS) SHALL BE USED. WELDING OF GRADE 60 REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING LOW HYDROGEN ELECTRODES. WELDING OF GRADE 40 REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING E70 XX ELECTRODES. WELDING WITHIN 4" OF COLD BENDS IN REINFORCING STEEL IS NOT PERMITTED. SEE REINFORCING NOTE FOR MATERIAL REQUIREMENTS OF WELDED BARS. 6. COLD -FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SHAPE, SIZE, AND GAGE SHOWN ON THE PLANS. PROVIDE MINIMUM SECTION PROPERTIES INDICATED. ALL COLD -FORMED STEEL FRAMING SHALL CONFORM TO THE A.I.S.S. "SPECIFICATION FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS." 7. BOLTED CONNECTIONS SHALL USE BEARING TYPE ASTM A325 BOLTS (3/4" DIA.) AND SHALL HAVE A MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE. 8. NON-STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" DIA. ASTM A307 BOLTS UNLESS NOTED OTHERWISE. 9. ALL STEEL WORK SHALL BE PAINTED IN ACCORDANCE WITH THE DESIGN & CONSTRUCTION SPECIFICATION AND IN ACCORDANCE WITH ASTM A36 UNLESS NOTED OTHERWISE. 10. ALL WELDS TO BE 1/4" FILLET UNLESS NOTED OTHERWISE. 11. TOUCH UP ALL FIELD DRILLING AND WELDING WITH 2 COATS OF GALVACON (ZINC RICH PAINT OR APPROVED EQUAL. MASONRY: 1. WORK: PROVIDE EVERYTHING REQUIRED TO COMPLETE UNIT MASONRY AS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 2. QUALITY STANDARDS: PROVIDE EXPERIENCED, WELL -TRAINED WORKERS COMPETENT TO COMPLETE THE WORK AS SPECIFIED. MATERIALS: 1. MORTAR AS PER ASTM C270. TYPE S. ONE PART PORTLAND CEMENT. ONE-HALF PART LIME. NOT MORE THAN FOUR AND ONE-HALF PARTS SAND, MEASURED DAMP AND LOOSE. COMPRESSIVE STRENGTH OF 1800 PSI AT 28 DAYS. 2. MORTAR MATERIALS: PORTLAND CEMENT, TYPE I OR II. AGGREGATE, CLEAN, SHARP SAND. LIME, QUICK LIME ASTM C5. HYDRATED LIME, TYPE S. WATER, CLEAN AND POTABLE. 3. PROVIDE CONCRETE UNIT MASONRY WHERE SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN AS MANUFACTURED BY: 4. CONCRETE UNIT MASONRY UNITS SHALL COMPLY WITH ASTM STANDARDS: 5. CONCRETE BRICKS, ASTM C55. HOLLOW LOAD -BEARING UNITS, ASTM C90. HOLLOW 6. NON -LOAD -BEARING UNITS, ASTM C129. SOLID LOAD -BEARING UNITS, ASTM C145. 7. GRADES AND TYPES: HOLLOW, LOAD -BEARING UNITS GRADE N. TYPE I, MEDIUM WEIGHT FOR EXTERIOR. HOLLOW, LOAD -BEARING UNITS GRADE S, TYPE II, LIGHTWEIGHT FOR INTERIOR. 8. GROUT SHALL BE TYPE II CEMENT CONFORMING TO ASTM C-150. AGGREGATE SHALL CONFORM TO ASTM C-144, SAND TO CONFORM TO ASTM C-404 AND LIME SHALL CONFORM TO ASTM C-207. 9. SEE CONCRETE SECTION THIS SPECIFICATION FOR THE REINFORCING STEEL MATERIAL REQUIREMENTS. 10. ACCESSORIES AND OTHER RELATED MATERIALS A. PROVIDE ALL ACCESSORIES AND MATERIALS AS REQUIRED FOR COMPLETE, PROPER INSTALLATION. 11. UNIT MASONRY INSTALLATION AND MORTAR APPLICATION 1911"1111111 I J rc:c 1. THE CONTRACTOR SHALL PREPARE SURFACES, FURNISH ALL PAINT, MATERIAL, LABOR AND EQUIPMENT REQUIRED FOR THE PAINTING OF ALL SURFACES AS REQUIRED BY THE DRAWINGS AND SPECIFIED HEREIN. 2. PAINTS TO BE APPLIED IN ALL WORKMANLIKE MANNER. UPON COMPLETION, REMOVE ALL MATERIALS AND DEBRIS CAUSED BY THIS CONTRACTOR, ALL HARDWARE, FLOORS, GLASS, FRAMES FIXTURES AND THE LIKE SHALL BE THOROUGHLY CLEANED OF PAINT. 3. REGULATORY REQUIREMENTS: ALL MATERIALS MUST COMPLY WITH AIR POLLUTION CONTROL REGULATIONS, SUCH AS L.A. COUNTY APCD RULE 1113 AND BAY AREA PCD REG. 3. 4. MATERIAL SHALL BE AS INDICATED ON PAINT SCHEDULE BELOW AND DRAWINGS. 5. ALL STEEL COLUMNS AND MISC. METALS SHALL BE PRIMED AND PAINTED. 6. FIRE PREVENTION: TAKE EVERY PRECAUTION AT THE END OF THE DAY TO REMOVE OILY RAGS AND COMBUSTIBLE MATERIALS FROM THE SITE OR STORE IN METAL CONTAINER WITH TIGHT COVERS. 7. EXTERIOR PAINT SYSTEMS (EPS): 7.1. FERROUS METALS; DOORS AND FRAMES: (MDF) 1-2 MILS PER COAT FRAZEE PAINT - COLOR TO MATCH EXISTING BUILDING 1ST COAT: 664 RUST STOP 2ND COAT: 124 MIRROGLIDE S/G ACRYLIC SEMI -GLOSS 3RD COAT: 124 MIRROGLIDE S/G ACRYLIC SEMI -GLOSS. 7.2. ALUMINUM OR GALVANIZED STEEL: (MDF) 1-2 MILS PER COAT FRAZEE PAINT - COLOR PER PLAN 1ST COAT: 661 METAL PLAN 2ND COAT: 124 MIRROGLIDE S/G ACRYLIC SEMI -GLOSS 3RD COAT: 124 MIRROGLIDE S/G ACRYLIC SEMI -GLOSS. 7.3. PLASTER, CONCRETE, MASONRY: (MDF) 1-2 MILS PER COAT FRAZEE PAINT - COLOR TO MATCH EXISTING BUILDING 1ST COAT: 061 AQUA SEAL 2ND COAT: 124 MIRROGLIDE S/G 3RD COAT: SEMI -GLOSS - 124 MIRROGLIDE S/GINTERIOR PAINT SYSTEMS (IPS): 8. INTERIOR PAINT SYSTEMS (IPS): 8.1. GYPSUM DRYWALL (NON -EPDXY): RADIO FACILITY (MDF) 1-2 MILS PER COAT FRAZEE PAINT - COLOR TO BE WHITE 1ST COAT: 061 AQUA SEAL 2ND COAT: 124 MIRROGLIDE S/G 3RC COAT: SEMI -GLOSS - 124 MIRROGLIDE S/G 8.2. TELEPHONE BACKBOARD: FRAZEE PAINT - COLOR TO BE WHITE 1ST COAT: 367 FRAFLO V/C 2ND COAT: FLAT FIRE PAINT #505 BY FLANECRETE (AS SPECIFIED) 3RD COAT: 124 MIRROGLIDE S/G ACRYLIC SEMI -GLOSS OVERCOAT: 124 MIRROGLIDE S/G ACRYLIC SEMI -GLOSS (TINT TO MATCH WALL) 8.3. PLASTER, CONCRETE, MASONRY: (MDF) 1-2 MILS PER COAT FRAZEE PAINT - COLOR TO BE WHITE 1ST COAT: LATEX PRIMER SEALER - 065 ACRY PRIME 2ND COAT: SEMI -GLOSS - 124 MIRROGLIDE S/G 3RD COAT: SEMI -GLOSS - 124 MIRROGLIDE S/G SIGNS. 1. INSTALL EMERGENCY INFORMATION PLACARD NEAR ENTRANCE GATE OF EQUIPMENT AREA (OR MOST VISIBLE PLACE ON OUTSIDE COMPOUND WALL). PLACARD IS TO CONTAIN SITE NAME, SITE NUMBER, COMPANY NAME, ADDRESS INFORMATION, AND A "800" NUMBER TO DIAL IN CA! OF EMERGENCY. PLACARD IS TO CONSIST OF HIGH CONTRAST LETTERING (WHITE BACK GROUt W/ RED LETTERING) BEHIND VANDAL RESISTANT LEXAN COVER. 2. INSTALL ADDRESS PLACARD NEAR ENTRANCE GATE OF EQUIPMENT AREA (OR FACING STREET OF ASSOCIATED ADDRESS). PLACARD IS TO CONTAIN 12" TALL HIGH CONTRAST LETTERING (WHITE BACK GROUND AND RED LETTERS) BEHIND VANDAL RESISTANT LEXAN COVER. SPECIAL INSPECTIONS: 1. SPECIAL INSPECTIONS & SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE (FOR SEISMIC DESIGN CATEGORY C) ARE REQUIRED FOR THE FOLLOWING ITEMS ON THIS PROJECT: 1.1. STRUCTURAL STEEL PER IBC 1704.3 AND 1707.2. APPROVED FABRICATOR CERTIFICATES FROM AISC OR ICC MUST BE PROVIDED TO THE BUILDING OFFICIAL TO WAIVE INSPECTION OF SHOP FABRICATION. 1.2. REINFORCED CONCRETE AND POST -INSTALLED ANCHORS PER IBC 1704.4 & 1707.7 AND THE ICC-ES REPORT FOR THE PRODUCT(S) USED. 2. THE LPG STANDBY EMERGENCY GENERATOR IS A DESIGNATED SEISMIC SYSTEM REQUIRING SEISMIC QUALIFICATION IN ACCORDANCE WITH IBC 1708.4 & ASCE 7. DUTIES & RESPONSIBILITIES OF SPECIAL INSPECTOR: A. SPECIAL INSPECTOR SHALL OBSERVE WORK ASSIGNED TO VERIFY ACCORDANCE WITH APPROVED DESIGN DRAWINGS & SPECIFICATIONS. B. CONSTRUCTION MANAGER IN CHARGE OF SPECIAL INSPECTION SHALL PROVIDE INSPECTION REPORTS TO BUILDING OFFICIAL & ENGINEER OF RECORD. DISCREPANCIES SHALL BE BROUGHT TO IMMEDIATE ATTENTION OF CONTRACTOR FOR CORRECTION. IF UNCORRECTED, DISCREPANCIES SHALL BE SUBMITTED TO DESIGN AUTHORITY AND BUILDING OFFICIAL. C. UPON COMPLETION OF ASSIGNED WORK, THE ENGINEER SHALL SEAL & SIGN APPROPRIATE FORMS CERTIFYING TO BEST OF KNOWLEDGE THE WORK IS IN CONFORMANCE WITH APPROVED PLANS & SPECIFICATION & APPLICABLE WORKMANSHIP PROVISIONS OF THE CODE. D. SPECIAL INSPECTIONS ARE TO BE PERFORMED INDEPENDENTLY AND IN ADDITION TO BUILDING OFFICIAL'S SCHEDULED INSPECTIONS. SITE CONDITION: verizon✓ 126 WEST GEMINI DRIVE TEMPE. ARIZONA 05293 PHONE: 480.752.7238 DESIGN MANAGEMENT PROFESSIONAL• f SiinoDesignl 16616 EAST PALISADES BOULEVARD UNIT /102 FOUNTAIN HILLS, ARIZONA 85268 PHONE 480.836.1701 FAX: 480.836.1004 WWW.SIINODESIGN.COM ENGINEERING CONSULTANT: DRAWING APPROVALS (SIGNATURES) STE ACO'JS.'ON/PROPERTY CONSTRUCTION MANAGER V_RZON WR, IESS R" ENO BEER LANDLORD APPROVAL DRAWN RY: JN'0 CIEECXCD P: CMS SNEDULE OF REVISIONS NO DATE DESCR PTION BY 3 2 8/C8/16 CITY COMMENTS CMS 1 4/13/'6 COMMENTS CNS 0 4/05/16 PRELIM CD CNS SITE NAME: TUC VENTANA 2 SC SITE ADDRESS: 2150 E. TANGERINE ROAD 030 VA'. -LEY, AZ 85755 SEAL SHEET TITLE: GENERAL NOTES 1. THE OPERATION OF THE FACILIFTY SHALL RESPOND TO, AND COMPLETE ALL IDENTIFIED MAINTENANCE AND REPAIR OF THE FACILITY WITHIN 30 DAYS OF RECEIVING WRITTEN NOTICE OF THE PROBLEM. SHEET NUMBER: GN-2 V/CINITY MAP i N.T.S. �Oo 9 F�o AZ ysj� aO q tANf£R\NE ® o OL w �y W )L a PALISADES RD SURVEY DATE 03/23/2016 BASIS OF BEARING BEARINGS SHOWN HEREON ARE BASED UPON U.S. STATE PLANE NAD83 COORDINATE SYSTEM ARIZONA STATE PLANE COORDINATE CENTRAL ZONE, DETERMINED BY CPS OBSERVATIONS. BENCHMARK PROJECT ELEVATIONS ESTABLISHED FROM CPS DERIVED ORTHOMETRIC HEIGHTS BY APPLICATION OF NGS 'GEOID 12A' MODELED SEPARATIONS TO ELLIPSOID HEIGHTS DETERMINED BY OBSERVATIONS OF THE 'SMARTNET' REAL TIME NETWORK. ALL ELEVATIONS SHOWN HEREON ARE REFERENCED TO NAVD88. FLOOD ZONE THIS PROJECT APPEARS TO BE LOCATED WITHIN FLOOD ZONE "X". AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN ACCORDING TO FEDERAL EMERGENCY MANAGEMENT AGENCY FLOOD INSURANCE RATE MAP(S), MAP ID µ04019C1090L, DATED 06/16/2011. UTILITY NOTES SURVEYOR DOES NOT GUARANTEE THAT ALL UTILITIES ARE SHOWN OR THEIR LOCATIONS ARE DEFINITE. IT 15 THE RESPONSIBILITY OF THE CONTRACTOR AND DEVELOPER TO CONTACT BLUE STAKE AND ANY OTHER INVOLVED AGENCIES TO LOCATE ALL UTILITIES PRIOR TO CONSTRUCTION. REMOVAL, RELOCATION AND/ OR REPLACEMENT IS THE RESPONSIBILITY OF THE CONTRACTOR. SURVEYOR'S NOTES SURVEYOR HAS NOT PERFORMED A SEARCH OF PUBLIC RECORDS TO DETERMINE ANY DEFECT IN TITLE ISSUED. THE BOUNDARY SHOWN HEREON IS PLOTTED FROM RECORD INFORMATION AND DOES NOT CONSTITUTE A BOUNDARY SURVEY OF THE PROPERTY. ALL DISTANCES SHOWN HEREON ARE GRID DISTANCES. LESSOR'S LEGAL DESCRIPTION THE LAND REFERRED TO HEREIN BELOW IS SITUATED IN THE COUNTY OF PIMA, STATE OF ARIZONA, AND IS DESCRIBED AS FOLLOWS: LOT 13 OF THE AMENDED FINAL PLAT OF ORO VALLEY MARKETPLACE, A SUBDIVISION OF PIMA COUNTY, ARIZONA ACCORDING TO THE MAP OR PLAT THEREOF OF RECORD IN THE OFFICE OF THE COUNTY RECORDER OF PIMA COUNTY, ARIZONA IN BOOK 64 OF MAPS AND PLATS AT PAGE 42 THEREOF. SCHEDULE "B" NOTE REFERENCE IS MADE TO THE TITLE REPORT ORDER µAZ-FCOP-IMP-N/A-1-16-51005101, ISSUED BY FIDELITY NATIONAL TITLE INSURANCE COMPANY, DATED FEBRUARY 4, 2016. ALL EASEMENTS CONTAINED WITHIN SAID TITLE REPORT AFFECTING THE IMMEDIATE AREA SURROUNDING THE LEASE HAVE BEEN PLOTTED. ITEMIZED NOTES: 1. ITEM NUMBERS 1-7, 9-11, 14, 19, 21, 25, 29, 31, 32, 34 AND 36-41 ARE NOT SURVEY MATTERS, OR HAVE NO EFFECT IN THE AREA OF THIS SURVEY. 2. ITEM NUMBERS B. 12. 17. 18. 22-24. 26, 27, 30, 33, AND 35 ARE SHOWN AND NOTED ON THE SURVEY DRAWING 3. ITEM NUMBERS 13, 15, 16, 20, 28 ARE ALL BLANKET IN NATURE OVER THE ENTIRE PARCEL AREA. THE SURVEYORS OPINION IS THAT NO SCHEDULE "B" ITEMS PROVIDED BY SAID REPORT AFFECT THE PROPOSED WIRELESS FACILITY PREMISES SHOWN HEREON. LEGEND AP ASPHALT g TELECOMMUNICATIONS ANTENNA CURBLINES BLDG TOP OF BUILDING ED AIR CONDITIONING UNIT CONCRETE LIMITS GONG EDGE OF CONCRETE - UTILITY MANHOLES EXISTING BUILDINGS D/W ACCESS DRIVEWAY 0" UTILITY METER PARKING STRIPES EP EDGE OF PAVEMENT FIRE HYDRANT W W WATER LINES FC LP FACE OF CURB LIGHT POLE � POWER POLE SS — SS SEWER LINES NO NATURAL GRADE LIGHT POLE — GAS GAS GAS LINES R/W RIGHT OF WAY mh ELECTRICAL TRANSFORMER E E ELECTRIC LINES SW SIDEWALK v POSITION OF — F/0 F/0— FIBER OPTIC LINES V ROOF VENT GEODETIC COORDINATES SPOT ELEVATION - STREET CENTERLINES DR © ROOF DRAIN SKYLIGHT WATER CONTROL VALVE - - SUBJECT PROPERTY LINE pd ADJACENT PROPERTY LINE TREES © GAS VALVE _ _ - - - _ _ - - - - - EASEMENT LINES µ 30 EASEMENT CLIENT: ELECTRIC WATER METER DKT. 13360, PG. 146 TRANSFORMER r — — — — — — — — — — — — — — —� _ — — — — — — --�N 8 R0ENT 77D86 LIPGM 966 ■ UTILITY VAULT// venzon —JCi/ _LmK_R L r — � \ 126 WEST GEMINI DRIVE — — — A 1 TEMPE, ARIZONA 85283 ®❑ ❑ �® ❑ ® �❑ ®� ❑❑ ❑ 0 ❑ ❑ ® — — — — \<1 A�tE3 PHONE: (480) 752-7238 1 1 ® TPz1h2 ® E]® \� DESIGN MANAGEMENT PROFESSIONAL: D ❑ I I 4TER\ / ® 19® so 0 0 ®❑® ® I I/pl1 aSiinoDesign ^ I ® ® 19 0 0 0 0 0 0 STORM DRAIN ( STORM DRAIN __ 1. El I ® ® ® ® ® ® ® ® ® ® ® STORM DRAIN M AI� I ® _ 16616 EAST PAUSADES BLVD, SUITE 102 ® ® ® ® ® ® ® ® ® ® I FOUNTAIN HILLS, ARIZONA 85268 ® ® ® ® ® ® ® ® ® ® ® BACK -FLOW / III - I PHONE: (48 8366-17 1 ® ® ® ® ® 0 ® ® ® ® ®❑ ® PREVENTER ( I I —.. I wwwsm 6z ® ® ® I SURVEYING CONSULTANT: bit z^ �► /I NI 19 19 0 19 El® 0 0 0 0 ® N/,j IIIiII=}I I �r z N I m0 ® ® ® ® ❑® ® ® ® ® m X II I ® ® ® ® ® ® ❑ ® ® ® ® � I I I -� 410 EAST SOUTHERN AVENUE ❑ ❑ 00 ❑ ❑ ❑= ❑ ❑ 1:1❑ I III i TEMPE. AR120NA 85282 (480)659-4072 4 I DRAWING APPROVALS (SIGNATURES) f= 11 I �1 SEE d�F DETAIL / / I I — _— -- SITE ACQUISITION/PROPERTY - - - - - - - - - - LS-2 q�� Q CONSTRUCTION MANAGER c� o 0-I i I = — . }r —{ _ - I I I VERIZON WIRELESS RF ENGINEER POD CA 0 LANDLORD APPROVAL / I DRAWN BY: RC i U CHECKED BY: MF SCHEDULE OF REVISIONS z z I Il/J NO DATE DESCRIPTION BY I JJJ a J J / 2 04/07/16 ROOF SHOTS (A) RC 1 04/05/16 COMMENTS CK }-- Y— —}— —1-- / 0 03/31/16 PRELIM SUBMITTAL RC WATER I PARCEL / -�-.- - - r-- FT SITE NAME: TUC VENTANA_2_SC DKT. 113077,EPGN 1� /f / µ 33 EASEMENT SITE ADDRESS: / f 2150 E. TANGERINE ROAD / f ���Q DKT. 13571, PG. 9� D/W f/f ORO VALLEY, AZ 85755 SEAL: \ \ \ \ \ \ \ \ Q`��• V BOOK 62,TPG. 19 p�t0 f / 9. µ 2\ \ µ 27 EASEMENT 4 EASEMENT DKT. 13222, PG. 835 O90 \ \ \ f ff DKT. 13303, PG. 224� // SHEET TITLE: DK18, EASEMENT T. 3091, PG. 1254/ GRAPHIC SCALE SITE SURVEY µ 22 EASEMENT IN pD�) SHEET NUMBER: DKT. 13149, EMG. 44 \ L Inch = tL µ 23 EASEMENT / / 60 L� 1 DKT. 13149, PC.47 � � N / STORM DRAIN CLIENT: — — — — — — — INLET — — TRANSFORMERS FIBER-OPTIC . _ __ __ _ J ——F26ZQ4— — — — — — — GAS GAS VAULT — — — — — — — — — - venzon W W c \ — — — — W W W S W W W 2 'B � o. v W W W W W W OSEW — 5 — SS SS —SS Ste= 5'S —SS — —SS=-� Ss -SS- S R-SS —ASS rSS�— SS- s — — — -- Ste'— �5'�� —S rS — STBRM-0RA _ _ _ _ _ _ —tL-ETR E;A — \ 126 WEST GEMINI DRIVE $C70.3'9 — — — — — — — — — — — — JNLEI-—B�ARQS —GABS M�TERSI.,,d� ELFCT�IC, �� -Pc S DRAIN \ TEMPE, ARIZONA 85283 — — B Dc A^ ElL �- r�/(NE 27067 M DR PHONE: (480) 752-7238 BLDG BL2 DC.7 T — — — — — — — — — — — -�A�� — xOLEANOOT� DESIGN MANAGEMENT PROFESSIONAL: — y—' V - — — — — — — — — — — — — — — —{ © Fs CDR CDR CDR CDR Ll CDR CDR D� ROOF "" \ AC AC AC ll�-ACCESS TRUCK BAY AC n UNCIT UN T © UNIT © UNIT © UNIT UNIT UNIT AHATCH AC © TRUCK BAY \ F Si i no D e s i g n UNIT "V © UNIT UNIT BLDG AC Y y n 'V F ROOF •V UNIT AC ©•V 2700.5 Z ACCESS UNIT y y BLDG 16616 EAST PALISADES BLVD, SUITE 102 HATCH BOLLARDS FOUNTAIN HILLS, ARIZONA 85268 GONG �2691.6 U � PHONE: (480) 836-1701 FS a FAX: (480) 836-1004 CONIC %Ct£ANIX1T © © © © © © © © © © © CONSULTANT: SURVEYING CONSULTANT: AC UNI fFs�� © © n © © n AC © © © AC © © 82705.3 f COLDG NCRETE PAVEMENT bit 2701.3 'Vy •V UNIT UNIT STORM DRAIN BLDG �V © ° ° I�I ° ° ° AC AC may` OSTORM DRAIN I Z6]1.O /f UNIT UNIT 259L5. �C7I� AP UN T © © n © FS n n ICaV FS ° ° ° © © OSTORM DRAIN � �- BBLDGa TEMPE,410 ARIZONA EASTS85 82RN AVENUE AP( 80)659-4072 © © © © UNIT © © © © n �F26922 © DRAWING APPROVALS (SIGNATURES) ASPHALT PAVEME T © SITE ACQUISITION/PROPERTY .2702.4 Z © © © R © © © U T © © © qC © e e/ LDG EXISTING fAP70.9 BLDG o F2593.0 UNIT / CONSTRUCTION MANAGER BUILDING 2694.OIcy/J / / VERIZON WRELESS RF ENGINEER n n n n n C7 © ILA n ° ° n ° FS / AP © F2597.6 / LANDLORD APPROVAL © z © n © © © © `2694.2 ° ° \269412 ° / DRANK BY: RC a FS FS 2707.4 / / CHECKED BY: MF < n a PROPOSED n n n AC © © n © n AC © © BLDG Z / .V UNIT UNIT y SCHEDULE OF REVISIONS STEEL © © Q © © © © n n n © 'V o / / NO DATE DESCRIPTION BY I -BEAMS F2594.9 Q n UNCIT n © © © UNIT n n n n V © / 2 04/07/16 ROOF SHOTS (A) RC G2702.7 EXISTING "GNG' STORE Q AC / 1 04/05/16 COMMENTS CK n n © n © © •V UNIT © z7o2.7 I!0 03/31/16 PRELIM SUBMITTAL RC 270M2.9 16'x24' AC BLDG POSITION OF GEODETIC AC EQUIPMENT AC AC AC AC AC UNIT •V 2702.E © •V / SITE NAME: UNIT ^LEASE AREA BLDG TUC VENTANA_2 SC COORDINATES AC V V AC UNIT UNIT UNIT UNIT UNIT AC SECTOR "A" UNIT •V lJ O i UNIT ❑ UNIT POSITION OF GEODETIC n © / / y EAVE j,'>" y v V 'V .V •V V V NC EZAIlVE95 82oce COORDINATES-, "BS / �'?C'OAMERA UNIT SITE ADDRESS: BLDG BLDG a�c'Z BLDG B270G 6 'V y / 2150 E. TANGERINE ROAD c2704.5 BLDG 2 BLDG 0 y / ORO VALLEY, AZ 85755 \27033 BLDG / 2705d CAP 2706.7 BLDG 4202.4CONCRETE SIDEWALK BLDG BLDCAMERA // EAVE 2670.9 — —EA CONCRETE SIDEWALK— EAvf PEAK ENTRY BOLLARDS EAR PEAK ENTRY BOLLARDS ENTRY 90LLARD9APfAP SEAL: AP AP AP AP AP O� LEGEND AP ASPHALT TELECOMMUNICATIONS ANTENNA CURBLINES BLDG TOP OF BUILDING AIR CONDITIONING UNIT CONCRETE LIMITS CONIC EDGE OF CONCRETE AU ® UTILITY MANHOLES EXISTING BUILDINGS O/W ACCESS DRIVEWAY o® UTILITY METER PARKING STRIPES EP EDGE OF PAVEMENT FIRE HYDRANT W W WATER LINES', FC FACE OF CURB E SS SS SEWER LINES LP NG LIGHT POLE NATURAL GRADE (1 LIGHPOWT POLE— GAS — GAS — GAS LINES R/W RIGHT OF WAY ® ELECTRICAL TRANSFORMER E E ELECTRIC LINES SW SIDEWALK V POSITION OF F 0— / F 0— / FIBER OPTIC LINES V ROOF VENT GEODETIC COORDINATES _ STREET CENTERLINES OR ROOF DRAIN SPOT ELEVATION © SKYLIGHT pd WATER CONTROL VALVE - - SUBJECT PROPERTY LINE ® TREES © GAS VALVE - _ _ _ _ _ _ _ _ - _ ADJACENT PROPERTY LINE - EASEMENT LINES 9�Sg POSITION OF GEODETIC COORDINATES (SECTOR 'A') LATITUDE 32' 25' 32.0" NORTH (NAD83) GRAPHIC SCALE LCNGITUDE 110' 56' 30.4" WEST (NAD83) c w GROUND ELEVATION ® 2671.0' (NAVD88) SHEET TITLE: POSITION OF GEODETIC COORDINATES (SECTOR 'B") ( IN FEET) LATITUDE 32' 25' 31.8" NORTH (NAD83) ROOF DETAIL 1 inch = 30 fL LONGITUDE 110' 56' 24.4" WEST (NAD83) GROUND ELEVATION ® 2671.0' (NAV088) SHEET NUMBER: LS-2 CLIENT: OVERALL SITE PLAN KEYED NOTES: IV 1. EXISTING PARKING 2. EXISTING ELECTRIC TRANSFORMERS 3. EXISTING SKY LIGHT (TYP.) 4. EXISTING BUILDING TO BE UTILIZED 5. EXISTING BUILDING ENTRANCE. NEW LESSEE 24-HR BULDING ACCESS ENTRANCE 2 6. EXISTING ROOF HATCH. NEW LESSEE 24-HR ROOF ACCESS / \ 7. EXISTING HVAC (TYP.) 14 1 PROPERTY LINE 8. EXISTING PIPE (TYP.) I 1 s- SF --SS- ss w 9. EXISTING SOLAR SHADE CANOPY I I o 10. EXISTING EASMENTS (SEE SURVEY SHEET LS-1) 11. NEW ROOF MOUNTED CONDUITS FOR FIBER & ELECTRIC RUN, lb E7E7E] ® FINAL ROUTE TO BE DETERMINED. 1 _1 6 0 ❑ �❑ a® El ® ❑ ®� ❑❑ a ❑ ®❑ 12. NEW CABLE TRAY FOR HYBRID RUNS 14 1 N _ L_ ® 3 ❑ ❑ 7 ®' 13. NEW ROOF PAD ACCESS TO EQUIPMENT CABINET LOCATION 1 r n 14. NEW FAUX SCREEN BOX TO MATCH RFP BOX TYP.. I I n I I ® ® ® ® ®❑ ® ® BOB COLORED AND TEXTURED TO MATCH EXISTING BUILDING I I I H----- ❑ 15. NEW FRP SCREENING. COLORED AND TEXTURED TO MATCH I I 4 b ® ® ® ®❑® EXISTING BUILDING. 15 I cv ® ® ® ® ® ® ® ® ® ® 1 I j I \��� 13 ® ® ® a ® �® ® ®❑ 12 34 I 1 N` s - - - - - - - - - - - ❑ ®❑ ENLARGED VIEW \ o - I N.T.S. 11 ®❑ ® ® 12 ® ❑® ® 5 ® ® ® H . Two work'cg dcys be'ore yoj d'g, CALL FOR THE BLUE STAKE! 1 (602) 263-1100 or 1 (800) STAKE -IT (782-5348) (OUTSID- VAR'!'0'A COUNTY) LEGEND BLDG TOP OF BUILDING 0 STREET LIGHT CLF CHAIN LINK FENCE 7X FIRE HYDRANT CONC CONCRETE 10.3 POWER POLE D/W ACCESS DRIVEWAY $ POSITION OF FC FACE OF CURB GEODETIC COORDINATES NG NATURAL GRADE All SPOT ELEVATION R/W RIGHT OF WAY ® TREES 1; WATER CONTROL VALVE 4 NEW ANTENNA O GROUND ROD 4� EXISTING ANTENNA — GROUND BUS BAR Q REVISION ■ MECHANICAL GRND. CONN. O CONSTRUCTION KEYED NOTE • CADWELD ® GROUND ACCESS WELL x DETAIL REFERENCE ELECTRIC BOX TELEPHONE BOX `E_Y ELEVATION REFERENCE LIGHT POLE x SECTION REFERENCE GRAVEL ® PLYWOOD GROUT OR PLASTER o (E) BRICK SAND (E) MASONRY C� WOOD CONT. 0 CONCRETE WOOD BLOCKING ® STEEL EARTH W — W — W GAS GAS — GAS O/H 0/1 1 O/H —E —E E E — F/0 F/0 F/0 FB— FB FB FB CHAIN LINK FENCE CURBLINES WATER LINES GAS LINES OVERHEAD LINES ELECTRIC LINES (E) FIBER OPTIC LINES (N) FIBER OPTIC LINE STREET CENTERLINES RIGHT OF WAY LINES LEASE AREA LIMITS MAJOR CONTOUR INTERVAL MINOR CONTOUR INTERVAL o ap o 0 o ap APN: 220-04-3240 I - ZONING: TBD -- -- - - USE: COMMERCIAL Qf - - --1- PROPERTY LINE I I= = 0 a Iw Z jL-1J w O / v ACCESS a a � G�. ACCESS I 12 1 1 A•2 I I I 1 1 I I 1 1 I I I I I 14 15 --J 14 \ - - - ---- ----- - - - - -1±16 - - - - - f16'-11" 20'-0" 20'-0"'-11" ENLARGED VIEW N.T.S. verizoal 126 WEST GEMINI DRIVE TEMPE• ARIZONA 85293 PHONE: 480.752.7238 aSiinoDesign � 16616 EAST PALISADES BOULEVARD UNIT /102 FOUNTAIN HILLS. ARIZONA 85268 PHONE: 480.836.1701 FAX: 480.836.1004 WWW.SIINODESIGN.COM ENGINEERING CONSULTANT: DRAWING APPROVALS (SIGN'ATURLS) S'.TE ACOUSTCN/PROPERTY I CON'STRUCTON MANACER V_R ZO\ WRELESS R� LNC\EER LANDLORD APPROVAL DRAWN 3Y: JNOO CHECKED BY: CMS SCHEDULE OF REVISIONS NOI DAT- I D-SCRPTON BY 2 1 8/08/16 1 CITY COVMFNTS CMS 1 41131.6 COMMEN-S CMS 0 4/C5/16 PRELIM CD CMSI SITE NAME: TUC VENTANA 2 SC SITE ADDRESS: 2150 L. TANGERINE ROAD ORD VkIEY, AZ 85755 SEAL: SHEET TITLE: OVERALL SITE PLAN 07 1 21S-+EET NUNBER: ,' SCALE 1' 80'-0' i x17' SCALE: 1• 160'-0' B 4 0' � OVERALL SITE PLAN ANTENNA PLAN KEYED NOTES: 1. NEW (1) ANTENNA PER SECTOR ® 28'-0" RAD CENTER, TOTAL OF (2) SECTORS MOUNTED TO EXISTING BUILDING BEHIND NEW RFP SCREENING, , REFER STRUCTURAL ANALYSIS & EVALUATION REPORT. 2. EXISTING BUILDING PARALET 3. NEW CABLE TRAY FOR HYBRID RUNS 4. NEW VERTICAL RISER OF CABLE LADDER (INSIDE VERTICAL RISER OR SIMILAR, SEE DETAIL 11 ON SHEET A-4 5. NEW RRH ON NEW MOUNT, REFER STRUCTURAL ANALYSIS & EVALUATION REPORT. NEW ANTENNA LAYOUT N.T.S. 1 ANTENNA SECTION KEYED NOTES: 1. NEW ANTENNA (TYP. OF 2). 2. NEW PIPE AND SUPPORT KITS. I 3. EXISTING BUILDING. 3 4 NEW FRP SCREENING (TYP.). COLORED AND TEXTURED TO 1 2 MATCH EXISTING BUILDING. 5. RRH (BEYOND) 4� I I I I I R_AD CENTER I 28'-0" A.G.L.—I I 34 I I I I I I 1 I NOTES: L------ NEW FRP SCREENING SHALL _ BE PAINTED TO MATCH BUILDING COLOR. ANTENNA SECTION DETAIL N.T.S. 2 NOTE. CONTRACTOR TO VERIFY FOR FINAL RF DATA SHEETS WITH n CONSTRUCTION MANAGER PRIOR TO ANY CONSTRUCTION. NEW ANTENNA & HYBRIFLEX CABLE TABLE SECTOR AZIMUTH (� (FT) I �INE OF SIZE L(NT)H COAX TYPE ALPHA 150' 28'-0" 4 7/8" ±590' HYBRIFLEX BETA 260' 28'-0" 1 4 7/8" t32' HYBRIFLEX r O to to ENLARGED SITE PLAN KEYED NOTES: ® 8. NEW ANTENNA FLUSH MOUNTED ON EXISTING BUILDING (NEW ANTENNAS TO BE CONCEALED BY RF FRIENDLY SCREENING 1. LINE OF EXISTING BUILDING. PAINTED TO MATCH EXISTING BUILDING (TYP. OF 2), REFER 2. EXISTING HVAC (TYP.) STRUCTURAL ANALYSIS & EVALUATION REPORT. 3. EXISTING ROOF VENT PIPE (TYP.). 9. NEW ACCESS PATH FROM ROOF HATCH TO EQUIPMENT CABINET 4. NEW ROOF MOUNTED CONDUIT FOR POWER & FIBER RUNS. 10. EXISTING PROPERTY LINE FINAL POWER & FIBER SOURCES TO BE DETERMINED, SEE 11. EXISTING ROOF SURFACE DETAIL 2 ON SHEET A-4 12. NEW (1) ANTENNA PER SECTOR, TOTAL OF (2) SECTORS 5. NEW EQUIPMENT CABINET (CHARLES CUBE) MOUNTED ON NEW MOUNTED TO EXISTING BUILDING ® 28'-0" RAD CENTER, REFER PLATFORM (PLATFORM AND CABINET TO BE CONCEALED BY 5 STRUCTURAL ANALYSIS & EVALUATION REPORT. SIDED SCREENING TO MATCH EXISTING HVAC SCREENING), 13. NEW VERTICAL RISER OF CABLE LADDER (INSIDE VERTICAL REFER STRUCTURAL ANALYSIS & EVALUATION REPORT. RISER OR SIMILAR, SEE DETAIL 11 ON SHEET A-4 6. NEW CABLE TRAY FOR HYBRID CABLE RUNS, SEE DETAIL 1 ON 14. NEW FAUX SCREEN BOX TO MATCH RFP BOX (TYP.). COLORED SHEET A-4. AND TEXTURED TO MATCH EXISTING BUILDING, REFER 7. NEW RRH ON NEW MOUNT (NEW MOUNT TO BE CONCEALED BY STRUCTURAL ANALYSIS & EVALUATION REPORT. 5 SIDED SCREENING TO MATCH EXISTING HVAC SCREENING) (TYP. OF 2), REFER STRUCTURAL ANALYSIS & EVALUATION REPORT. I I I I o I I I 2'-0" I -dlL-j4-- I I I �f 2'-0" t 5'- L I V I 2'-7" 1 II 3 N I I cV I I JI� NEW ANTENNA & COAXIAL CABLE SPECS. I N.T.S. j 3 ENLARGED SITE PLAN I I LI I ____J I I I I I I v I I I I I I I I I I I L----J I I I I I I I I I _J CLIENT: NOTES: 1. NEW FRP SCREENING SHALL BE PAINTED TO MATCH BUILDING COLOR. verizon� 2. REFER STRUCTURAL ANALYSIS &EVALUATION REPORT FOR PLATFORM AND SCREENING DETAILS 126 WEST GEMINI DRIVE TEMPE. ARIZONA 85293 PHONE: 480.752.7238 DESIGN MANAGEMENT PROFESSIONAL' 1 NORTH ImSiinoDesign 16616 EAST PALISADES BOULEVARD UNIT J102 FOUNTAIN HILLS. ARIZONA 85268 PHONE: 480.836.1701 FAX: 480.836.1004 WWW.SIINODESIGN.COM ENGINEERING CONSULTANT: DRAWING APPROVALS (SIGNATURES) SITE ACQJ!SIT:ON/�ROPLRTY CWNSTR'JCTON MANACER VER'IZON WIRELESS RF ENC:NEER LA\X0R7 A—ROVAL DRAWN BY: JNCO CHECKED BY: CMS SNID'J� E OF REV'S'ONS NOI DATE I DESORPTION I BY 2 8/08/16 CITY CCVM'NTS CMS 1 4/13/"6 COMMENTS CMS 0 4/05/16 PRELIV CD CMS SITE NAME: TUC VENTANA 2 SC SITE ADDRESS: 2150 E. TA\G=R'\E ROAD ORO VALLEY. AZ 85755 SEAL: SHEET TITLE: ENLARGED SITE PLAN SHEET NUV9ER: A-2 22•:34• SCALE: 1/2• 1'-0- 11":17• SCALE: 1/4• = 1'-0- 2 1' 00 2 14 ELEVATION KEYED NOTES: ® CUENT: 1. EXISTING BUILDING 2. EXISTING HVAC BEYOND (TYP.) ver■�zon� 3. LINE OF EXISTING ROOF 4. NEW (1) ANTENNA PER SECTOR, TOTAL OF (2) SECTORS MOUNTED TO EXISTING BUILDING ® 28'-0" RAD CENTER 126 WEST GEMINI DRIVE 5. NEW EQUIPMENT CABINET MOUNTED TO NEW NON —PENETRATION TEMPI. ARIZONA 85293 PLATFORM PLATFORM AND CABINET TO BE CONCEALED BY 5 PHONE: 480.752.7238 DESIGN MANAGEMENT PROFESSIONAL' SIDED SCREENING TO MATCH EXISTING HVAC SCREENING), REFER STRUCTURAL ANALYSIS & EVALUATION REPORT. 6. NEW RRHs MOUNTED ON NEW MOUNT (TRIPOD MOUNT TO BE Ei S i i n o D e s i n CONCEALED BY 5 SIDED SCREENING TO MATCH EXISTING HVAC g SCREENING) (TYP. OF 2). REFER STRUCTURAL ANALYSIS & 16616 EAST PALISADES BOULEVARD EVALUATION REPORT UNIT ;toe 7. NEW FAUX SCREEN BOX TO MATCH RFP BOX (TYP.). COLORED AND FOUNTAIN HILLS, 808 8 o85268 TO MATCH EXISTING BUILDING, REFER STRUCTURAL PHOTEXTURED FAX: 480.836.1004 ANALYSIS & EVALUATION REPORT WWW.SIINODESION.COM 8. NEW FRP SCREENING. COLORED AND TEXTURED TO MATCH EXISTING ENGINEERING CONSULTANT: BUILDING, REFER STRUCTURAL ANALYSIS & EVALUATION REPORT. NOTES: 1. NEW FRP SCREENING SHALL BE PAINTED TO MATCH BUILDING COLOR. 2. REFER STRUCTURAL ANALYSIS & EVALUATION REPORT FOR PLATFORM AND SCREENING DETAILS T I ¢ I z 1 Z 1W- W z 0 ui ¢ W z z Z W Z <L U FW- 0 z a. ¢¢ w I0 z I o O N SOUTH ELEVATION r---------- I I 2 n I I I II U O z 0 J F j W z m 0 ¢ U Z 0-En En OJ tL X 0 ¢ W tl p Z 0 D_ Z 0 I¢ _ r M ¢ I M +1 22'x34' SCALE: 1/8' = 1*-0' 11'x17" SCALE: 1/16' 1'-0' 8 6 4 2 0 8' DRAWING APPROVALS (S!CNATURES) STE ACOU'ST ON/PROPERTY CONSTRUCT'ON MANAGER VER ZO\ WRELESS R� ENG\EER LANDLORD APPROVAL DRAW BY: J\'GO CHECKED BY: CNS SCHEDULE OF REVISIONS NOI DATE I DESCRPTIOK I SY 2 1 8/08/16 1 CITY COMMENTS CMS 1 4/13/16 COMMENTS CNS 0 4/05/16 PRELIM CD CMS SITE NAME: TUC VENTANA 2 SC SITE ADDRESS: 2150 E. TANGERINL ROAD ORD VA' LEY, AZ 85755 SEAL SHEET TITLE: ELEVATION SHEET NUV9ER: 1 A-3 COVERED COAX CABLE TRAY KEYED NOTES: O ROOF MOUNTED CONDUIT KEYED NOTES: # ANDREW PART # RT-ST OR ANDREW PART # RR-TFS CLIENT: 1. SELF SPLICING COAX COVER (4 RUN COAX) 1. RIGID GALV. STEEL CONDUIT PER SITE PLAN 2. GALVANIZED SUPERSTRUT PIPE STRAP (TYP.) APPROVED EQUAL OR APPROVED EQUAL verizon� 2. PVC ROOF SLEEPER FOR 4 RUNS 3. %" UNISTRUT (12" LONG) OF COAX, UV RATED 4. 4x4 UV RESISTANT PVC SLEEPER 3. HARDWARE KIT (ITEMS 4-6) 4. ROOFTOP COVER CLIP 1 5. %%1Y4" GALV. BOLT KIT 5. USE LIQUID NAILS ADHESIVE TO ATTACH SLEEPER 6. ROOF 126 WEST GEMINI DRIVE PHONE: 4810.752.72383 6. GALV. FLAT WASHER 3 �� 410 DESIGN MANAGEMENT PROFESSIONAL F Siin0Design 4 5 6 1 2 3 -A- N as 0 _ 06 o e `t 16616 EAST PALISADES BOULEVARD UNIT /102 FOUNTAIN HILLS. ARIZONA 85268 PHONE 480.836.1701 FAX: 480.836.1004 WWW.SIINODESIGN.COM ENGINEERING CONSULTANT: 2wr 4 5 REFER TO ANDREW PART# -- 36.1" MT-F1542-11_REV C OR APPROVED EQUIV. COVERED COAX CABLE TRAY N.T.S. 1 ROOF MOUNTED CONDUIT DETAIL N.T.S. 2 STEP OVER DETAIL N.T.S. I 3 RRU MOUNT DETAIL N.T.S. 4 CRAVJINO APPROVALS (S'GNATURES) RF NOTICE SIGN NOTES: OWNER SIGN KEY NOTES: ® BATTERY WARNING SIGN KEY ® CABLE TRAY KEY NOTES: 1. (QTY 1) SIGN SHALL BE MOUNTED ON LIGHT POLE 2. RF NOTICE SIGN SHALL BE 12" PLACED 5'-0" FROM THE 1. 6" WIDE 4" HIGH SIGN WITH WHITE LETTERS ON WHITE BACKGROUND N OTES: 1. RED DIAMOND 2. YELLOW DIAMOND 3. BLUE DIAMOND 1. ANTENNA FRP SCREENING, REFER STRUCTURAL ANALYSIS & EVALUATION REPORT. 2. 6" STRAIGHT ALUMINUM LADDER TRAY (LAT-06-4D BY SITEPR01 & STRAIGHT COVER LT-VSS-06-A OR APPROVED STE ACQUSTON/PROPLRT.Y CONSTRICTION MANAGER FINISH GRADE NOTICE5. �•� . Radio frequency fields beyond this point may exceed the FCC general public exposure limit. 6" 1 This is an Antenna Site Site ID: For information, call: 800-264-6620 4. WHITE DIAMOND 3" X 3" DIAMOND HAZARD SIGN 1 , 0=; 2 3 4 5 EQUAL) 3. 6" INSIDE VERTICAL RISER WITH SPLICE PLATES LT-RI90-06-4D AND 6" INSIDE RISER COVERS LT-VRI90-06-A OR APPROVED EQUAL) 4. USED Y2"0 ANCHOR ROD W/ HILII HIT-HY 150 MAX EPDXY, W/4X EMBEDMENT 5. EXISTING CMU WALL 6. EXISTING ROOF o 1 2 VERZON WR:-ESS R= ENG\EER ANOLORo APPRovAL oRnwv BY: N00 CHECKEDS SCHEDULE OF REVISIONS NO DAL CESCRPTION BY 3 2 8/08/16 CITY COMMENTS CNS - 1 4/13/-6 COMMENTS CNS Obay.11p-ted aIgnsandsft. 9uldellnes fa working In radio frequency NOTE: monmenta. ALL FACILITY PLAQUES TO BE ..�.".r�.o". m.�..�.� wa.a.......ro"r.,an"� MOUNTED NEAR ANTENNA NOTE: ALL FACILITY PLAQUES TO BE MOUNTED AT EQUIPMENT CABINET NOTE ALL FACILITY PLAQUES TO BE MOUNTED AT EQUIPMENT CABINET r-- - '.'i ; 2 I 4 0 4/05/16 PRELIV CD CNS SITE NAME: TUC VENTANA 2 SC sTE ADDRESS: 2150 E. TANGERINE ROAD ORO VALLEY, A7 85755 RF NOTICE SIGN I N-T-S- 5 OWNER SIGN N.T.S. I 6 EMERGENCY PLAQUE DETAIL N.T.S. 7 DETAIL KEYED NOTES: ® 2'-O" 1. EXISING CMU WALL 6 ?N 2. 5/16" TH. X 2.5" COX PLYWOOD IN 7 DETAIL KEYED NOTES: ® 1. L2 1/2"x 2 1/2"x 3/16" FRAME 2. ENVISOR 52V SCREEN PANEL BY CITYSCAPE INC. ALL SIDES DETAIL KEYED NOTES: ® 1. ENVISOR 52V SCREEN PANEL BY CITYSCAPE INC. ALL SIDES 2. L2 }"x 2 }"x 1j" FRAME 1/8" TH. FRP LAYUP (TOP & BOT.) 4 3. 1"x 1/8" BAR w (4)1/4" TEK SCREWS EACH SIDE 3. SITEPRO BTS44-S 4'x4' NON PENETRATING PLATFORM 3. SIMPSON TITEN 1/4" MASONRY SCREWS 7 4. L3X3X1/4, A36, 6'-B" LONG 4. EXPANDED SHEET 3/4-#0.081 I 0 3 SEAL: 5. #14 SCREWS 6. 3/16" TH. FRP PANEL. 7. 5/16" TH. X 2.5" COX PLYWOOD IN w 1/8" TH. FRP LAYUP VERT. FLANGE a 8. 3/16" TH. FRP CORNER INLAY Ln 3 5 3'-9Y2"--- to i� i0 c7 8 5 4 B ' I 5 I r A o 2y2" I 2 v I 3 o SYMM. _ T"1 SHEET nTLE: CONSTRUCTION C ELEVATION DETAILS 7 SECnON'A'-SCREEN BOX SECTION "B"- SCREEN BOX PLAN SHEET NUMBER:: ANTENNA SCREEN DETAIL N.T.S. I 8 ENCLOSURE PLAN N.T.S. 9 PLATFORM ELEVATION N.T.s.10 VERTICAL CABLE TRAY DETAIL N-T-s- 11 "-4 ELECTRICAL GENERAL REQUIREMENTS A. SCOPE OF WORK: ALL MATERIAL SHALL BE NEW UNLESS OTHERWISE INDICATED. FURNISH ALL LABOR, EQUIPMENT, TECHNICAL SUPERVISION, AND INCIDENTAL SERVICES REQUIRED TO COMPLETE, TEST AND LEAVE READY FOR OPERATION THE ELECTRICAL SYSTEMS AS SPECIFIED AND AS INDICATED ON DRAWINGS. B. ORDINANCES AND CODES: PERFORM ALL WORK IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL ORDINANCES AND REGULATIONS, THE RULES AND REGULATIONS OF NFPA, NECA, AND UL, UNLESS OTHERWISE INDICATED. C. UNLESS OTHERWISE INDICATED, ALL REQUIRED PERMITS, LICENSES, INSPECTIONS, APPROVALS AND FEES FOR ELECTRICAL WORK SHALL BE SECURED AND PAID FOR BY THE CONTRACTOR. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES, RULES AND REGULATIONS. D. THE DRAWINGS SHOW THE LOCATION AND GENERAL ARRANGEMENT OF EQUIPMENT, ELECTRICAL SYSTEMS AND RELATED ITEMS. THEY SHALL BE FOLLOWED AS CLOSELY AS ELEMENTS OF THE CONSTRUCTION WILL PERMIT. FURNISH AND INSTALL A COMPLETE ELECTRICAL SYSTEM AS DEPICTED FROM THE PLANS AND SPECIFICATIONS HEREIN, AS NOTED OR IMPLIED, NOT LIMITED TO WHAT IS SHOWN. ALL APPURTENANCES, BASES, PADS, SUPPORTS NOT INDICATED TO MAKE A WORKING SYSTEM MUST BE INCLUDED IN CONTRACTOR'S BID. E. IF THERE APPEARS TO BE ANY ITEMS IN CONFLICT WITH THE DRAWINGS, INCONSISTENCIES WITH DESIGN OR INTENT, OR NEED FOR CLARIFICATIONS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO CLARIFY THESE ITEMS PRIOR TO BID IN WRITING WITH THE ENGINEER. IF THE CONTRACTOR FAILS TO CLARIFY ANY QUESTIONS OR INCONSISTENCY, HE ACCEPTS RESPONSIBILITY TO CORRECT AT HIS COST ANY SUCH ITEM TO MEET INTENT AS DEFINED BY ENGINEER. F. EXAMINE THE DRAWINGS OF OTHER TRADES AND VERIFY THE CONDITIONS GOVERNING THE WORK ON THE JOB SITE. ARRANGE WORK ACCORDINGLY, PROVIDING SUCH FITTINGS, CONDUIT, JUNCTION BOXES AND ACCESSORIES AS MAY BE REQUIRED TO MEET SUCH CONDITIONS. G. COORDINATE ARRANGEMENT, MOUNTING AND SUPPORT OF ELECTRICAL EQUIPMENT WITH OTHER TRADES. H. VISIT THE SITE, EXAMINE AND VERIFY THE CONDITIONS UNDER WHICH THE WORK MUST BE CONDUCTED BEFORE SUBMITTING PROPOSAL. THE SUBMITTING OF A PROPOSAL IMPLIES THAT THE CONTRACTOR HAS VISITED THE SITE AND UNDERSTANDS THE CONDITIONS UNDER WHICH THE WORK MUST BE CONDUCTED. NO ADDITIONAL CHARGES WILL BE ALLOWED BECAUSE OF FAILURE TO MAKE THIS EXAMINATION OR TO INCLUDE ALL MATERIALS AND LABOR TO COMPLETE THE GROUNDING AND BONDING WORK. A. EQUIPMENT GROUNDING: COMPLY WITH NFPA 70, ARTICLE 250, FOR TYPES, SIZES, AND QUANTITIES OF EQUIPMENT GROUNDING CONDUCTORS, UNLESS SPECIFIC TYPES, LARGER SIZES, OR MORE CONDUCTORS THAN REQUIRED BY NFPA 70 ARE INDICATED. P. ALL CUTTING, PATCHING AND REPAIR WORK SHALL BE PERFORMED BY THE CONTRACTOR THROUGH APPROVED, QUALIFIED SUBCONTRACTORS. CONTRACTOR SHALL INCLUDE FULL COST OF SAME IN BID. Q. PROVIDE ALL EXCAVATION, TRENCHING, TUNNELING, DEWATERING AND BACKFILLING REQUIRED FOR THE ELECTRICAL WORK. COORDINATE THE WORK WITH OTHER EXCAVATING AND BACKFILLING IN THE SAME AREA. R.INSPECT THE INSTALLATION OF ALL EQUIPMENT PER THE MANUFACTURER'S RECOMMENDATION AND APPLICABLE CODES. S. PROVIDE UL APPROVED FIRE -STOPPING SYSTEM FOR ALL PENETRATIONS PASSING THROUGH FIRE RATED ASSEMBLIES. T. COMPLY WITH NECA 1. U. PROVIDE COMPLETE OPERATION AND MAINTENANCE INSTRUCTIONAL MANUALS COVERING ALL ELECTRICAL EQUIPMENT HEREIN SPECIFIED, TOGETHER WITH PARTS LISTS. V.CONTRACTOR SHALL SUBMIT TO THE ARCHITECT/ENGINEER, RECORD DRAWINGS ON ELECTRONIC MEDIA OR BOND WHICH HAVE BEEN NEATLY MARKED TO REPRESENT AS -BUILT CONDITIONS FOR ALL NEW ELECTRICAL WORK. W. SUBMIT FOR APPROVAL SHOP DRAWINGS FOR ALL ELECTRICAL SYSTEMS OR EQUIPMENT BUT NOT LIMITED TO THE ITEMS LISTED BELOW: 1. PANELBOARDS 2. DISCONNECT SWITCHES 3. WIRING DEVICES 4. LIGHTING FIXTURES 5. FUSES I. BIDS SHALL BE BASED UPON MANUFACTURED EQUIPMENT SPECIFIED. VOLUNTARY ALTERNATES MAY BE SUBMITTED FOR CONSIDERATION, WITH LISTED ADDITION OR DEDUCTION TO THE BID. J. WARRANTY: CONTRACTOR SHALL WARRANTY THAT THE ELECTRICAL INSTALLATION IS FREE FROM DEFECTS AND AGREES TO REPLACE OR REPAIR, TO THE OWNER'S SATISFACTION, ANY PART OF THIS ELECTRICAL INSTALLATION WHICH BECOMES DEFECTIVE WITHIN A PERIOD OF TWO YEARS FROM THE DATE OF SUBSTANTIAL COMPLETION FOLLOWING FINAL ACCEPTANCE, PROVIDED THAT SUCH FAILURE IS DUE TO DEFECTS IN THE EQUIPMENT, MATERIAL, WORKMANSHIP OR FAILURE TO FOLLOW THE CONTRACT DOCUMENTS. K.CONTRACTOR SHALL BE RESPONSIBLE FOR ANY TEMPORARY SERVICES INCLUDING EQUIPMENT AND INSTALLATION REQUIRED TO MAINTAIN OPERATION AS A RESULT OF ANY EQUIPMENT FAILURE OR DEFECT DURING WARRANTY PERIOD. L. FILE WITH THE OWNER ANY AND ALL WARRANTIES FROM THE EQUIPMENT MANUFACTURERS INCLUDING THE OPERATING CONDITIONS AND PERFORMANCE CAPACITIES THEY ARE BASED ON. M.IN GENERAL, DEMOLITION WORK IS INDICATED ON THE DRAWINGS. HOWEVER, THE CONTRACTOR SHALL VISIT THE JOB SITE TO DETERMINE THE FULL EXTENT AND CHARACTER OF THIS WORK. N. UNLESS SPECIFICALLY NOTED TO THE CONTRARY, REMOVED MATERIALS SHALL NOT BE REUSED IN THE WORK. SALVAGED MATERIALS THAT ARE TO BE REUSED SHALL BE STORED SAFE AGAINST DAMAGE AND TURNED OVER TO THE APPROPRIATE TRADE FOR REUSE. SALVAGED MATERIALS OF VALUE THAT ARE NOT TO BE REUSED SHALL REMAIN THE PROPERTY OF THE OWNER UNLESS SUCH OWNERSHIP IS WAIVED. ITEMS ON WHICH THE OWNER WAIVES OWNERSHIP SHALL BECOME THE PROPERTY OF THE CONTRACTOR, WHO SHALL REMOVE AND LEGALLY DISPOSE OF SAME, AWAY FROM THE PREMISES. 0.CONSULT WITH THE OWNER'S REPRESENTATIVE AS TO THE METHODS OF CARRYING ON THE WORK SO AS NOT TO INTERFERE WITH THE OWNER'S OPERATION ANY MORE THAN ABSOLUTELY NECESSARY. ACCORDINGLY, ALL SERVICE LINES SHALL BE KEPT IN OPERATION AS LONG AS POSSIBLE AND THE SERVICES SHALL ONLY BE INTERRUPTED AT SUCH TIME AS WILL BE DESIGNATED BY THE OWNER'S REPRESENTATIVE. W.PROVIDE AND INSTALL ARC -FLASH HAZARD LABELS ON EACH ELECTRICAL EQUIPMENT AND ENCLOSURES DEFINED BY NFPA 70E. LABELS SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 70E AND CONTAIN AS A MINIMUM: 1. VOLTAGE (PHASE -PHASE) 2. FLASH PROTECTION BOUNDARY (INCHES) 3. INCIDENT ENERGY LEVEL AT THE WORKING DISTANCE (CA/CM2) 4. PERSONNEL PROTECTIVE EQUIPMENT (PPE) CLASS AND DESCRIPTION. 5. RESTRICTED APPROACH BOUNDARY (INCHES) 6. LIMITED SHOCK APPROACH BOUNDARY (INCHES) 7. PROHIBITED SHOCK APPROACH BOUNDARY (INCHES) B. PROVIDE EQUIPMENT GROUNDING CONDUCTORS IN EACH RACEWAY. C. ALL GROUND/BONDING CONDUCTORS SHALL BE MULTI -CONDUCTOR TYPE (UL LABELED ROPE STRAND BUILDING WIRE CLASS "M") BARE OR INSULATED AS NOTED OR REQUIRED. CONDUCTORS AND CABLES A. CONDUCTOR MATERIAL: COPPER COMPLYING WITH NEMA WC 70; STRANDED CONDUCTOR, RATED FOR 60OV, 98% CONDUCTIVITY. B. CONDUCTOR INSULATION TYPES: TYPE THHN-THWN, SO, COMPLYING WITH NEMA WC 70. CONDUCTOR INSTALLATION WILL BE CONTINUOUSLY COLOR COATED UP TO SIZE 500 KCMIL C. CONCEAL CABLES IN FINISHED WALLS, CEILINGS, AND FLOORS, UNLESS OTHERWISE INDICATED. D. USE CONDUCTOR NOT SMALLER THAN 12 AWG FOR POWER AND LIGHTING CIRCUITS. UNLESS INDICATED OTHERWISE, ALL CIRCUITS SHALL BE 2#12, 1#12G, 3/4"C. E. USE CONDUCTOR NOT SMALLER THAN 14 AWG FOR CONTROL CIRCUITS, PROVIDED BY ELECTRICAL CONTRACTOR. F. SUPPORT COMMUNICATION CABLES FROM STRUCTURE ABOVE, USING SPRING METAL CLIPS OR PLASTIC CABLE TIES TO SUPPORT CABLES FROM STRUCTURE. G. USE "STA-KON" CONNECTORS TO TERMINATE STRANDED CONDUCTORS #10 AWG AND SMALLER TO SCREW TERMINALS. H. CONDUCTOR AND INSULATION APPLICATIONS: 1. FEEDERS: TYPE THHN-THWN, SINGLE CONDUCTORS IN RACEWAY. 2. BRANCH CIRCUITS, INCLUDING IN CRAWLSPACES: TYPE THHN-THWN, SINGLE CONDUCTORS IN RACEWAY. 3. CORD DROPS AND PORTABLE APPLIANCE CONNECTIONS: TYPE SO, HARD SERVICE CORD 4. CLASS I CONTROL CIRCUITS: TYPE THHN -THHWN IN RACEWAY. 5. CLASS 11 CONTROL CIRCUITS: POWER LIMITED CABLE RACEWAYS AND BOXES A. SURFACE METAL RACEWAYS: GALVANIZED STEEL WITH SNAP -ON COVERS. FINISH WITH MANUFACTURER'S STANDARD PRIME COATING. WIREMOLD OR EQUAL. SIZE/TYPE AS SHOWN ON DRAWINGS. B. MINIMUM RACEWAY SIZE: 3/4-INCH TRADE SIZE. C. INSTALL CONDUIT IN ACCORDANCE WITH NECA NATIONAL ELECTRICAL INSTALLATION STANDARDS' D. ROUTE CONDUITS IN FINISHED AREAS WITH EXPOSED CEILINGS AT UNDERSIDE OF STRUCTURAL DECK OR AS HIGH AS POSSIBLE. WHERE STEEL METAL DECK ON STEEL JOIST CONSTRUCTION, ROUTE CONDUITS ABOVE JOISTS. DO NOT SECURE CONDUIT TO BOTTOM OF JOISTS. E. RACEWAY APPLICATIONS: 1. OUTDOORS ABOVE GRADE AND WET LOCATIONS: RIGID STEEL OR IMC. 2. OUTDOORS, BELOW GRADE: SCHEDULE 80 PVC WITH RIGID STEEL SWEEPS. PROVIDE WITH #16 AWG CU TRACING WIRE WITH 12" SPARE ACCESSIBLE AT EACH END. 3. INDOORS, BELOW SLAB ON GRADE: SCHEDULE 80 PVC WITH RIGID STEEL SWEEPS. 4. INDOORS, NOT EXPOSED TO PHYSICAL DAMAGE: EMT 5. INDOORS, EXPOSED TO PHYSICAL DAMAGE (EXPOSED, BELOW 10'): RIGID STEEL OR IMC. 6. CONNECTIONS TO MOTORS AND TRANSFORMERS: LIQUID TIGHT FLEXIBLE METAL CONDUIT (LFMC) E. ALL FITTINGS MUST BE STEEL COMPRESSION TYPE OR STEEL SET SCREW TYPE. F. COMPLETED RACEWAY SYSTEMS SHALL BE REAMED AND SWABBED PRIOR TO CONDUCTOR INSTALL. WIRING DEVICES A. STRAIGHT -BLADE -TYPE RECEPTACLES: COMPLY WITH NEMA WD 1, NEMA WD 6, DSCC W-C-596G, AND UL 498. CONFIGURATION 5-20R DUPLEX RECEPTACLE. HUBBELL HBL 5352 OR EQUAL BY PASS & SEYMOUR OR LEVITON. B. GFCI RECEPTACLES: STRAIGHT BLADE, FEED -THROUGH TYPE, GENERAL DUTY GRADE, WITH INTEGRAL NEMA WD 6, CONFIGURATION 5-20R DUPLEX RECEPTACLE; COMPLYING WITH UL 498 AND UL 943. DESIGN UNITS FOR INSTALLATION IN A 2-3/4-INCH- (70-MM-) DEEP OUTLET BOX WITHOUT AN ADAPTER. HUBBELL GF5352 OR EQUAL BY PASS & SEYMOUR OR LEVITON. C. WALL SWITCHES: SINGLE AND DOUBLE -POLE SWITCHES: COMPLY WITH DSCC W-C-896F AND UL 20. HUBBELL WIRING DEVICE, KELLEMS 1220 SERIES OR EQUAL BY PASS & SEYMOUR OR LEVITON. D. WALL PLATES: PROVIDE STAINLESS STEEL WALL PLATES IN FINISHED AREAS E. WIRING DEVICE COLOR AS SELECTED BY ARCHITECT UNLESS OTHERWISE INDICATED OR REQUIRED BY NFPA 70. F. CONNECT WIRING DEVICE GROUNDING TERMINAL TO OUTLET BOX WITH BONDING JUMPER. USE OF QUICK GROUND STRAP OR SCREW IS NOT ACCEPTABLE. G. RECEPTACLES: IDENTIFY PANELBOARD AND CIRCUIT NUMBER FROM WHICH SERVED. USE ADHESIVE LABEL WITH BLACK FILLED LETTERING ON FACE OF WALL PLATE, AND DURABLE WIRE MARKERS OR TAGS INSIDE OUTLET BOXES. H. CORD AND PLUG SETS: MATCH VOLTAGE AND CURRENT RATINGS AND NUMBER OF CONDUCTORS TO REQUIREMENTS OF EQUIPMENT BEING CONNECTED. 1. CORD: RUBBER -INSULATED, STRANDED -COPPER CONDUCTORS, WITH TYPE SOW -A JACKET: WITH GREEN -INSULATED GROUNDING CONDUCTOR AND EQUIPMENT -RATING AMPACITY PLUS A MINIMUM OF 30 PERCENT. 2. PLUG: NYLON BODY AND INTEGRAL CABLE -CLAMPING JAWS. MATCH CORD AND RECEPTACLE TYPE FOR CONNECTION. ENCLOSED SWITCHES AND CIRCUIT BREAKERS A. FUSIBLE AND NON -FUSIBLE SWITCHES: NEMA KS 1, QUICK MAKE, QUICK -BREAK LOAD INTERRUPTER ENCLOSED KNIFE SWITCH TYPE HD, WITH CLIPS OR BOLT PADS TO ACCOMMODATE SPECIFIED FUSES (IF REQUIRED), EXTERNALLY OPERABLE LOCKABLE HANDLE WITH CAPABILITY TO ACCEPT TWO PADLOCKS, AND INTERLOCKED WITH COVER IN CLOSED POSITION. SQUARE D OR EQUAL. B. TOGGLE DISCONNECT SWITCH: HEAVY DUTY, 30A, 600 VOLT, DOUBLE OR THREE POLE AS REQUIRED, SINGLE THROW, MOTOR RATED SWITCH WITHOUT OVERLOAD PROTECTION. PROVIDE NEMA 1 ENCLOSURE AND PADLOCK ATTACHMENT. C. MOLDED -CASE CIRCUIT BREAKER: NEMA AB 1, WITH INTERRUPTING CAPACITY TO MEET AVAILABLE FAULT CURRENTS. THERMAL -MAGNETIC CIRCUIT BREAKER WITH INVERSE TIME -CURRENT ELEMENT FOR LOW-LEVEL OVERLOADS AND INSTANTANEOUS D. MOLDED -CASE SWITCHES: MOLDED -CASE CIRCUIT BREAKER WITH FIXED, HIGH -SET INSTANTANEOUS TRIP ONLY, AND SHORT-CIRCUIT WITHSTAND RATING EQUAL TO EQUIVALENT BREAKER FRAME SIZE INTERRUPTING RATING. E. COMPLY WITH APPLICABLE PORTIONS OF NECA 1, NEMA PB 1.1, AND NEMA PB 2.1 FOR INSTALLATION OF ENCLOSED SWITCHES AND CIRCUIT BREAKERS. F. SET FIELD -ADJUSTABLE SWITCHES AND CIRCUIT -BREAKER TRIP AND TIME DELAY SETTINGS. G. LABEL EACH DISCONNECT WITH ENGRAVED METAL OR LAMINATED -PLASTIC NAMEPLATE MOUNTED WITH CORROSION -RESISTANT SCREWS. INDICATE SOURCE AND LOAD SERVED. ENCLOSED CONTROLLERS A. ENCLOSURES: FLUSH -OR SURFACE -MOUNTING CABINETS AS INDICATED. NEMA 250, TYPE 1, UNLESS OTHERWISE INDICATED TO COMPLY WITH ENVIRONMENTAL CONDITIONS AT INSTALLED LOCATION. B. SELECT HORSEPOWER RATING OF CONTROLLERS TO SUIT MOTOR CONTROLLED. C. FOR CONTROL EQUIPMENT AT WALLS, BOLT UNITS TO WALL OR MOUNT ON LIGHTWEIGHT STRUCTURAL -STEEL CHANNELS BOLTED TO WALL. FOR CONTROLLERS NOT AT WALLS, PROVIDE FREESTANDING RACKS. MAGNETIC TRIP ELEMENT FOR SHORT CIRCUITS. ADJUSTABLE I CLIENT: MAGNETIC TRIP SETTING FOR CIRCUIT -BREAKER FRAME SIZES 250 A AND LARGER. verizoal 126 WEST GEMINI DRIVE TEMPE. ARIZONA 85293 PHONE: 480.752.7238 DESIGN MANAGEMENT PROFESSIONAL• ®SiinoDesign 16616 EAST PALISADES BOULEVARD UNIT #102 FOUNTAIN HILLS, ARIZONA 85268 PHONE: 480.836.1701 FAX: 480.836.1004 WWW.SIINODESIGN.COM ENGINEERING CONSULTANT: D. INSTALL FREESTANDING EQUIPMENT ON CONCRETE BASES. I DRAWNG APPROVALS (SIGMA E. ENCLOSED CONTROLLER FUSES: INSTALL FUSES IN EACH FUSIBLE SWITCH. F. SELECT AND INSTALL HEATER ELEMENTS IN MOTOR STARTERS TO MATCH INSTALLED MOTOR CHARACTERISTICS. G. IDENTIFY ENCLOSED CONTROLLER, COMPONENTS, WITH ENGRAVED METAL OR LAMINATED - PLASTIC NAMEPLATE. IDENTIFY SOURCE AND LOAD SERVED. S TE ACQU'.S'TON/°ROP;RTY CONSTRJCTON MANAGER VER.ZON WR= ;SS RE ENONEER H. SET FIELD -ADJUSTABLE SWITCHES AND CIRCUIT -BREAKER TRIP LANDLORD AP-ROVAL RANGES. I. MANUAL CONTROLLER: NEMA ICS 2, GENERAL PURPOSE, CLASS A, WITH "QUICK -MAKE, QUICK -BREAK" TOGGLE OR PUSHBUTTON ACTION, MARKED TO SHOW WHETHER UNIT IS "OFF," "ON," OR "TRIPPED," AND OVERLOAD RELAY. J. MAGNETIC CONTROLLER: NEMA ICS 2, CLASS A, FULL VOLTAGE, NONREVERSING, ACROSS THE LINE, UNLESS OTHERWISE INDICATED. 1. CONTROL CIRCUIT. 120 V. OBTAINED FROM INTEGRAL CONTROL POWER TRANSFORMER WITH SUFFICIENT CAPACITY TO OPERATE CONNECTED PILOT, INDICATING AND CONTROL DEVICES, PLUS 100 PERCENT SPARE CAPACITY. 2. OVERLOAD RELAY: AMBIENT -COMPENSATED TYPE WITH INVERSE -TIME -CURRENT CHARACTERISTIC AND NEMA ICS 2, CLASS 20 TRIPPING CHARACTERISTIC. PROVIDE WITH HEATERS OR SENSORS IN EACH PHASE MATCHED TO NAMEPLATE FULL -LOAD CURRENT OF SPECIFIC MOTOR TO WHICH THEY CONNECT AND WITH APPROPRIATE ADJUSTMENT FOR DUTY CYCLE. DRAWN BY: „Y00 CHECKED BY: CVS SCHEDULE OF REV'SIONS NO I DATL I O:SCR'PTION BY 2 B/C8/16 I CITY COMMENTS CMS 1 4/13/'6 COMMENTS CMS 0 4/05/16 FKLIV C0 CMS SITE NAME: TUC VENTANA 2 SC K. COMBINATION MAGNETIC CONTROLLER: FACTORY -ASSEMBLED COMBINATION CONTROLLER AND DISCONNECT SWITCH. 1. FUSIBLE DISCONNECTING MEANS: NEMA KS 1, HEAVY-DUTY, FUSIBLE SWITCH WITH REJECTION -TYPE FUSE CLIPS RATED FOR FUSES. SELECT AND SIZE FUSES TO PROVIDE TYPE 2 PROTECTION ACCORDING TO IEC 947-4-1, AS CERTIFIED BY AN NRTL. SEAL: L. ACCESSORIES: 1. DEVICES SHALL BE FACTORY INSTALLED IN CONTROLLER ENCLOSURE, UNLESS OTHERWISE INDICATED. 2. PUSH-BUTTON STATIONS, PILOT LIGHTS: NEMA ICS 2, HEAVY-DUTY TYPE. 3. INDICATING LIGHTS: RUN (RED), OFF OR READY (GREEN). 4. AUXILIARY CONTACTS: PROVIDE TWO NORMALLY OPEN (N.O.) AND TWO NORMALLY CLOSED (N.C.) CONTACTS. 5. SELECTOR SWITCH: NEMA ISC 2, MOUNTED IN FRONT COVER TO READ 'HAND/OFF/AUTO,' PROVIDE AUXILIARY CONTACT FOR AUTO POSITION MONITORING. 6. CONTROL RELAYS: AUXILIARY AND ADJUSTABLE TIME -DELAY RELAYS. SITE ADDRESS: 2150 L. TAN'GLRNL ROAD ORO VALLEY, AZ 85755 SHEET TTLE: ELECTRICAL NOTES SHEET NUVB:.R: E-1 A. COORDINATE LAYOUT AND INSTALLATION OF PANELBOARDS AND COMPONENTS WITH OTHER CONSTRUCTION THAT PENETRATES WALLS OR IS SUPPORTED BY THEM, INCLUDING ELECTRICAL AND OTHER TYPES OF EQUIPMENT, RACEWAYS, PIPING, AND ENCUMBRANCES TO WORKSPACE CLEARANCE REQUIREMENTS. B. COMPLIANCE WITH REQUIREMENTS PROVIDE PRODUCTS BY GE, SIEMENS OR ENGINEER APPROVED EQUAL. C. PHASE AND GROUND BUSES SHALL BE HARD -DRAWN COPPER, 98 PERCENT CONDUCTIVITY. D. SHORT-CIRCUIT RATING: FULLY RATED TO INTERRUPT SYMMETRICAL SHORT-CIRCUIT CURRENT AVAILABLE AT TERMINALS. E. ALL LUGS AND CONNECTORS SHALL BE RATED FOR 75'C MINIMUM. F.INSTALL PANELBOARDS AND ACCESSORIES ACCORDING TO NEMA PB 1.1. G. MOUNT TOP OF TRIM 74 INCHES (1880 MM) ABOVE FINISHED FLOOR, UNLESS OTHERWISE INDICATED. H.STUB FOUR 1-INCH (27-GRC) EMPTY CONDUITS FROM RECESSED PANELBOARD INTO ACCESSIBLE CEILING SPACE OR SPACE DESIGNATED TO BE CEILING SPACE IN THE FUTURE. STUB FOUR 1-INCH (27-GRC) EMPTY CONDUITS INTO RAISED FLOOR SPACE OR BELOW SLAB NOT ON GRADE. I. CREATE A DIRECTORY TO INDICATE INSTALLED CIRCUIT LOADS AFTER BALANCING PANELBOARD LOADS OR CREATED BY RETROFITTING. OBTAIN APPROVAL BEFORE INSTALLING. USE A COMPUTER OR TYPEWRITER TO CREATE DIRECTORY; HANDWRITTEN DIRECTORIES ARE NOT ACCEPTABLE. COORDINATE FINAL DIRECTORY ROOM NAMES AND NUMBERS WITH (OWNER) (FACILITY ENGINEER). J. PANELBOARD NAMEPLATES: LABEL EACH PANELBOARD WITH ENGRAVED METAL OR LAMINATED -PLASTIC NAMEPLATE MOUNTED WITH CORROSION -RESISTANT SCREWS. IDENTIFY SOURCE FED FROM K. LOAD BALANCING: AFTER SUBSTANTIAL COMPLETION, BUT NOT MORE THAN 60 DAYS AFTER FINAL ACCEPTANCE, MEASURE LOAD BALANCING AND MAKE CIRCUIT CHANGES. L. ON COMPLETION OF INSTALLATION, INSPECT INTERIOR AND EXTERIOR OF PANELBOARDS. REMOVE PAINT SPLATTERS AND OTHER SPOTS. VACUUM DIRT AND DEBRIS; DO NOT USE COMPRESSED AIR TO ASSIST IN CLEANING. REPAIR EXPOSED SURFACES TO MATCH ORIGINAL FINISH. M. LIGHTING AND APPLIANCE BRANCH -CIRCUIT PANELBOARDS 1. BRANCH OVERCURRENT PROTECTIVE DEVICES: BOLT -ON CIRCUIT BREAKERS, REPLACEABLE WITHOUT DISTURBING ADJACENT UNITS. N. MOLDED -CASE CIRCUIT BREAKERS: UL 489, WITH INTERRUPTING CAPACITY TO MEET AVAILABLE FAULT CURRENTS. 1. THERMAL -MAGNETIC CIRCUIT BREAKERS: INVERSE TIME -CURRENT ELEMENT FOR LOW-LEVEL OVERLOADS, AND INSTANTANEOUS MAGNETIC TRIP ELEMENT FOR SHORT CIRCUITS. ADJUSTABLE MAGNETIC TRIP SETTING FOR CIRCUIT -BREAKER FRAME SIZES 250 A AND LARGER WITH RESTRICTED ACCESS COVER. 0. MOLDED -CASE CIRCUIT -BREAKER FEATURES AND ACCESSORIES: 1. LUGS: MECHANICAL STYLE, SUITABLE FOR NUMBER, SIZE, TRIP RATINGS, AND CONDUCTOR MATERIALS. 2. APPLICATION LISTING: APPROPRIATE FOR APPLICATION; TYPE SWD FOR SWITCHING FLUORESCENT LIGHTING LOADS; TYPE HACR FOR HEATING, AIR-CONDITIONING, AND REFRIGERATING EQUIPMENT. 3. GROUND -FAULT PROTECTION: INTEGRALLY MOUNTED RELAY AND TRIP UNIT WITH ADJUSTABLE PICKUP AND TIME -DELAY SETTINGS, PUSH -TO -TEST FEATURE, AND GROUND -FAULT INDICATOR. 4. SHUNT TRIP: 120-V TRIP COIL ENERGIZED FROM SEPARATE CIRCUIT, SET TO TRIP AT 75 PERCENT OF RATED VOLTAGE. 5. DO NOT USE TANDEM CIRCUIT BREAKERS. 6. PROVIDE LOCK ON DEVICES FOR CIRCUIT BREAKERS WHEN CALLED OUT ON PANEL SCHEDULES WITH 'LOD' DESIGNATION. 7. PROVIDE GROUND FAULT INTERRUPT 5MA CIRCUIT BREAKER WHEN CALLED OUT ON PANEL SCHEDULES WITH "GFI' DESIGNATION. 8. PROVIDE SHUNT TRIP BREAKERS WHEN CALLED OUT ON PANEL SCHEDULES WITH STB" DESIGNATION. P. ENCLOSURES: MOUNTING AS NOTED ON PANEL SCHEDULES. NEMA PB 1, RATED FOR ENVIRONMENTAL CONDITIONS AT INSTALLED LOCATION. a. INDOOR DRY LOCATIONS: NEMA 250, TYPE 1. b. OUTDOOR LOCATIONS: NEMA 250, TYPE 3R. c. OTHER WET OR DAMP INDOOR LOCATIONS: NEMA 250, TYPE 4. 1. CABINET FRONT: FLUSH OR SURFACE CABINET AS NOTED ON THE DRAWINGS, WITH FRONT WITH CONCEALED TRIM CLAMPS, PIANO TYPE HINGED DEAD FRONT COVER, HINGED DOOR, AND FLUSH LOCK ALL KEYED ALIKE. 2. DIRECTORY CARD: WITH TRANSPARENT PROTECTIVE COVER, MOUNTED IN METAL FRAME, INSIDE PANELBOARD DOOR. TVSS A. TRANSIENT VOLTAGE SURGE SUPPRESSION MUST MEET UL 1449 CLASS CM 80.000A PER PHASE, PARALLEL CONNECTION, INTERNAL DISCONNECT AND FUSING, WIRED WITH (WELDING OR BRAIDED) MULTI -CONDUCTOR WIRING, NO FERROUS CONDUIT, MAX LEAD LENGTHS 10'-0" AND SEPARATE GROUND, AS WELL AS GROUND TO NEUTRAL FOR EQUIPMENT (PANELS, ETC) LIEBERT, UNITED POWER, LEA DYNATEC OR ENGINEER APPROVED EQUAL. PROVIDE WITH THREE MODES OF PROTECTION: PHASE TO PHASE, PHASE TO GROUND, NEUTRAL TO GROUND. FUSES A. OBTAIN FUSES FROM A SINGLE MANUFACTURER. B. COORDINATE FUSE RATINGS WITH UTILIZATION EQUIPMENT NAMEPLATE LIMITATIONS OF MAXIMUM FUSE SIZE. C. EXAMINE UTILIZATION EQUIPMENT NAMEPLATES AND INSTALLATION INSTRUCTIONS. INSTALL FUSES OF SIZES AND WITH CHARACTERISTICS APPROPRIATE FOR EACH PIECE OF EQUIPMENT. D. INSTALL LABELS INDICATING FUSE REPLACEMENT INFORMATION ON INSIDE DOOR OF EACH FUSED SWITCH. E. SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY COOPER BUSSMAN, INC. OR EQUAL. F. CARTRIDGE FUSES: NEMA FU 1, NONRENEWABLE CARTRIDGE FUSE; CLASS AND CURRENT RATING INDICATED; VOLTAGE RATING CONSISTENT WITH CIRCUIT VOLTAGE. 1. SERVICE ENTRANCE: CLASS L, TIME DELAY. 2. FEEDERS: CLASS RK5 TIME DELAY. 3. MOTOR BRANCH CIRCUITS: CLASS RK1, TIME DELAY. 4. OTHER BRANCH CIRCUITS: CLASS RK1, TIME DELAY. G. COMPLY WITH: 1. NEMA FU 1 - LOW VOLTAGE CARTRIDGE FUSES. 2. NFPA 70 - NATIONAL ELECTRICAL CODE. 3. UL 198C - HIGH -INTERRUPTING -CAPACITY FUSES, CURRENT -LIMITING TYPES. 4. UL 198E - CLASS R FUSES. 5. UL 512 - FUSEHOLDERS LIGHTING A. PROVIDE LIGHTING FIXTURES AS INDICATED ON DRAWINGS. B. INSTALL BALLASTS, AND SPECIFIED ACCESSORIES AT FACTORY. INSTALL LAMPS ON PROJECT SITE AFTER FIXTURE INSTALLATION. C. FIXTURES: SET LEVEL, PLUMB, AND SQUARE WITH CEILINGS AND WALLS. INSTALL LAMPS IN EACH FIXTURE. D. SUPPORT LUMINAIRES INDEPENDENT OF CEILING FRAMING. SUPPORT RECESSED GRID LUMINARIES FROM TWO OPPOSITE CORNERS DIRECTLY TO STRUCTURE. WIRE OR ROD SHALL HAVE BREAKING STRENGTH OF THE WEIGHT OF FIXTURE AT A SAFETY FACTOR OF 3. E. INSTALL SURFACE MOUNTED LUMINAIRES AND EXIT SIGNS PLUMB AND ADJUST TO ALIGN WITH BUILDING LINES AND WITH EACH OTHER. SECURE TO PROHIBIT MOVEMENT. F.TIGHTEN ELECTRICAL CONNECTORS AND TERMINALS ACCORDING TO MANUFACTURER'S PUBLISHED TORQUE -TIGHTENING VALUES. IF MANUFACTURER'S TORQUE VALUES ARE NOT INDICATED, USE THOSE SPECIFIED IN UL 486A AND UL 4868. G. MAKE WIRING CONNECTIONS TO BRANCH CIRCUIT USING BUILDING WIRE WITH INSULATION SUITABLE FOR TEMPERATURE CONDITIONS WITHIN LUMINAIRE. H. BOND PRODUCTS AND METAL ACCESSORIES TO BRANCH CIRCUIT EQUIPMENT GROUNDING CONDUCTOR. I. CONNECT LUMINAIRES TO BRANCH CIRCUIT OUTLET BOXES PROVIDED UNDER RACEWAYS AND BOXES SECTION USING 1/2" FLEXIBLE CONDUIT. J. CLEAN ELECTRICAL PARTS TO REMOVE CONDUCTIVE AND DELETERIOUS MATERIALS. K. REMOVE DIRT AND DEBRIS FROM ENCLOSURES AND LENSES. L. CLEAN FINISHES AND TOUCH UP DAMAGE. M. PROVIDE PROGRAM RAPID START ELECTRONIC BALLASTS FOR LINEAR LAMPS: COMPLY WITH NEMA C82.11; SOUND RATING A OR BETTER; TOTAL HARMONIC DISTORTION RATING OF LESS THAN 2074 OPERATING FREQUENCY. 25 KHZ OR HIGHER, AND OPERATE WITHOUT VISIBLE FLICKER; LAMP CURRENT CREST FACTOR LESS THAN 1.7; POWER FACTOR SHALL BE 90% MINIMUM; BALLAST FACTOR SHALL BE .875 TO 1.00. N. FLUORESCENT LAMPS: COMPLY WITH FEDERAL TOXIC CHARACTERISTIC LEACHING PROCEDURE TEST, AND YIELD LESS THAN 0.2 MG OF MERCURY PER LITER, WHEN TESTED ACCORDING TO NEMA LL 1. PROVIDE FLUORESCENT LAMPS BY OSRAM SYLVANIA, PHILLIPS OR GENERAL ELECTRIC. TYPE AND COLOR TEMPERATURE AS SCHEDULED. ABBREVIATION A DESCRIPTION AMPERES AF AMPERES FRAME (BREAKER RATING) A.F.F. ABOVE FINISH FLOOR AIC AMPS INTERRUPTING CAPACITY AL AUDIENCE LEFT AH AMPERE HOURS AR AUDIENCE RIGHT AT AMPERES TRIP (BREAKER SETTING) ATS AUTOMATIC TRANSFER SWITCH AUX AUXILIARY AWG AMERICAN WIRE GAUGE BKR BREAKER BPS BOLTED PRESSURE SWITCH C CONDUIT CB CIRCUIT BREAKER CKT CIRCUIT CT CURRENT TRANSFORMER DEMO DEMOLITION DIM DIMENSION DISC DISCONNECT DP DISTRIBUTION PANEL DS DOWNSTAGE DWG DRAWING EC ELECTRICAL CONTRACTOR EGB EXTERIOR GROUND BUS ELEC ELECTRICAL EM / EMERG EMERGENCY EME ELECTROMAGNETIC ENERGY EMT ELECTRICAL METALLIC TUBING EO ELECTRICALLY OPERATED EWC ELECTRIC WATER COOLER EXIST. / (E) EXISTING XP EXPLOSION PROOF FA FIRE ALARM FLA FULL LOAD AMPS FLR FLOOR FOH FRONT OF HOUSE FU FUSE G/GRD/EG GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTER HOA HAND -OFF -AUTO HVAC HEATING, VENTILATION AND AIR CONDITIONING EQUIP. HP HORSEPOWER HV HIGH VOLTAGE HZ HERTZ IG ISOLATED GROUND IGZ ISOLATED GROUND ZONE IPGB INTERNAL PERIMETER GROUND BUS CONDUCTOR/HALO JB JUNCTION BOX KV KILOVOLT KVA KILOVOLT - AMPERES KW KILOWATT KWH KILOWATT - HOURS LA LIGHTNING ARRESTOR LP LIGHTING PANEL LOP LIGHTING DISTRIBUTION PANEL LPG LIQUEFIED PROPANE GAS LTV LET -THROUGH VOLTAGE LVLD LOW -VOLTAGE LOAD DISCONNECT MAX MAXIMUM MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MOP MAIN DISTRIBUTION PANEL MECH MECHANICAL MGB MASTER GROUND BUS MIN MINIMUM MISC. MISCELLANEOUS MLO MAIN LUGS ONLY MTD MOUNTED MTG MOUNTING NIU NETWORK INTERFACE UNIT N NEUTRAL NC NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NF NON -FUSIBLE NIC NOT IN CONTRACT NL NIGHT LIGHT NO NORMALLY OPEN NTS NOT TO SCALE OC ON CENTER OFCI OWNER FURNISHED, CONTRACTOR INSTALLED P POLE PB PUSHBUTTON STATION PH PHASE PXFMR POTENTIAL TRANSFORMER PDP POWER DISTRIBUTION PANEL RECEPT. RECEPTACLE RDP RECEPTACLE DISTRIBUTION PANEL RP RECEPTACLE PANEL (R) RELOCATED RSC RIGID STEEL CONDUIT SCHED SCHEDULE SO SERVICE DISCONNECT SWITCH SES SERVICE ENTRANCE SECTION SN SOLID NEUTRAL SGB SHELTER GROUND BUS / SUB -STATION GROUND BUS SPD SURGE PROTECTION DEVICE SW SWITCH SWBD SWITCHBOARD SWGR SWITCHGEAR TP TAMPER PROOF TB TERMINAL BOX TELECOM TELECOMMUNICATIONS TTB TELEPHONE TERMINAL BACKBOARD TGB TOWER GROUND BAR TYP TYPICAL XFMR / TR TRANSFORMER TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR U/G UNDERGROUND UE UNDERGROUND ELECTRICAL UT UNDERGROUND TELCO U.O.N. UNLESS OTHERWISE NOTED US UPSTAGE V VOLTS VSWR VOLTAGE STANDING WAVE RAT10 W WIRE WP WEATHERPROOF - NEMA 3R ELECTRICAL SYMBOLS UST NOT ALL MAY BE USED 0 TEST WELL/GROUND ROD p GROUND ROD - 5/8" x 10' COPPER CLAD ■ MECHANICAL CONNECTION • EXOTHERMIC WELD CONNECTION --c-- GROUNDING WIRE GROUND BAR r-* SURGE SUPPRESSOR GROUND BAR p FUSED DISCONNECT SWITCH ® METER AND MAIN BREAKER ® MANUAL XFR SWITCH AND GEN. RECPT. .116 TELCO BOARD E _ ELECTRICAL POWER -FS FIBER LINE SURFACE MOUNTED PANEL BOARD. 1-LINE DIAGRAM sl CIRCUIT BREAKER, FIXED MOUNTED. CIRCUIT BREAKER, DRAWOUT MOUNTING. FUSIBLE SWITCH. SIZE AS INDICATED ON DRAWINGS. DISTRIBUTION TRANSFORMER CURRENT TRANSFORMER METERING DEVICE .- PANELBOARD, MAIN LUG ONLY �•--- PANELBOARD, MAIN CIRCUT BREAKER • J TRANSFER SWITCH - MANUAL OR AUTOMATIC CLIENT: verizonJ 126 WEST GEMINI DRIVE TEMPI. ARIZONA 85293 PHONE: 480.752.7238 FE-SiinoDesign 16616 EAST PALISADES BOULEVARD UNIT #102 FOUNTAIN HILLS, ARIZONA 85268 PHONE: 480.036.1701 FAX: 480.836.1004 WWW.SIINODESIGN.COM ENGINEERING CONSULTANT: DRAWING APPROVALS (SIGNATURES) S'.TL ACQUS TON/PROPERTY CONSTRUCTCN MANAGER VLRZON WRLLESS R� LNG:N'LLR' LANDLORD APPROVAL DRAWN BY: JVGQ CPECKED BY: CMS SCHEDULE OF REVIS'ONS NO DATE DESCR PTION 6Y 3 2 8/08/16 CITY COVMENTS CMS 1 4/13/16 COMMENTS ICMS 0 1 4/C5/16 I PRELIM CJ CMs SITE NAME: TUC VENTANA 2 SC 51'E ADDRESS: 2150 E TANCLR'NE RCAD ORD VALLEY, AZ 85755 SEAL S FET 1'LE: ELECTRICAL NOTES SHEET NUV5ER: E-2 OVERALL SITE PLAN KEYED NOTES: 1. EXISTING SKY LIGHT (TYP.) 2. EXISTING BUILDING TO BE UTILIZED 3. EXISTING BUILDNG ENTRANCE. NEW LESSEE 24-HR BULDING ACCESS ENTRANCE 4. EXISTING ROOF HATCH. NEW LESSEE 24-HR ROOF ACCESS 5. EXISTING HVAC (TYP.) 6. EXISTING PIPE (TYP.) 7. NEW ROOF MOUNTED CONDUITS FOR FIBER & ELECTRIC RUN, FINAL ROUTE TO BE DETERMINED. 8. NEW CABLE TRAY FOR HYBRID RUNS 9. NEW ROOF PAD ACCESS TO EQUIPMENT CABINET LOCATION (TYP.) Two working doys before you dig, CALL FOR THE BLUE STAKE! 1 (602) 263-1100 or 1 (800) STAKE -IT (782-5348) (OUTSIDE MARICODA COUNTY) LEGEND BLDG TOP OF BUILDING ------ 0 STREET LIGHT CLF CHAIN LINK FENCE :qI� FIRE HYDRANT CONC CONCRETE `Q.) POWER POLE D/W ACCESS DRIVEWAY POSITION OF FC FACE OF CURB GEODETIC COORDINATES NG NATURAL GRADE SPOT ELEVATION R/W RIGHT OF WAYse ® TREES pd WATER CONTROL VALVE 4 NEW ANTENNA GROUND ROD 4.� EXISTING ANTENNA GROUND BUS BAR Q REVISION ■ MECHANICAL GRIND. CONN. O CONSTRUCTION KEYED NOTE • CADWELD (I GROUND ACCESS WELL x DETAIL REFERENCE ED ELECTRIC BOX TELEPHONE BOX ELEVATION REFERENCE '�!. 0 LIGHT POLE 10III, SECTION REFERENCE GRAVEL GROUT OR PLASTER ® PLYWOOD o (E) BRICK SAND ® (E) MASONRY ® WOOD CONT. C� WOOD BLOCKING 0 CONCRETE ® STEEL EARTH CHAIN LINK FENCE CURBUNES W — W W WATER LINES GAS —GAS— GAS GAS LINES 0/14-- O/H O/H OVERHEAD LINES — E — E — E E — ELECTRIC LINES F/0 F/0 F/0 (E) FIBER OPTIC LINES FB— FB— FB— F& (N) FIBER OPTIC LINE — — — — STREET CENTERLINES — — — — RIGHT OF WAY LINES — — — — LEASE AREA LIMITS — — — — — — — — — — MAJOR CONTOUR INTERVAL — — — — — — — — — — MINOR CONTOUR INTERVAL POWER PLAN PROPERTY LIN"" GAS-- GAS — I�A� FIO I—W—W W—W VVW W—W _- I W W W- W W W W W�W I— SS — SS — SS — SS — SS — SS SS — So — SS SSA SS WSS—W SS m SS -1—N SS — SS SS - SS SS SS — SS — SS SS_—cFt_-- E I �� I© C7 CJ O O •C7, O ❑ ❑ O El❑ � El El El 1-1 El N 4 ❑ ©. I I I I I II I I I 00 1 0 0 © 5 © 0 © © © OF © © N ❑ N N 0 N N oN N N A N N N N N N ❑ O N N o 0 A N 6 N N 0 N N N F N N n N N N 0 n N N n 99 � N N N N N N 0 �F900 N N N N N N N Ll9�y 'oN N N 0 N © N 0 N N N N N 9N N N 0 N N oN N ❑ N N N N N� N 00 I oo° N N N N N B N •❑ N N N o00000 00000d� o� oo ❑ ❑ ❑0 El ❑ ❑ 2 3 I ❑ CUENT. verizon✓ 126 WEST GEMINI DRIVE TEMPE. ARIZONA 85293 PHONE: 480.752.7238 DESIGN MANAGEMENT PROFESSIONAL.• NISHnoDesign 16616 EAST PALISADES BOULEVARD UNIT /102 FOUNTAIN HILLS. ARIZONA 85268 -1 PHONE: 480.836.1701 FAX: 480.836.1004 WWW.SIINODESIGN.COM ,1Sj ENGINEERING CONSULTANT I ST CI.F ' CII DRAWING APPROVALS (SIOKATURCS) OSTORM DRAIN STE ACOJ'S:TON/PROPERTY OSTORM DRAIN CONSiRJCT'.ON MANAGER OSTORM .RAIN VERIZON WIRELESS RF ENCNEER LANDLORD A�PROVAI. DRAWN BY: „NCO CHECKED BY: CMS SCHEDULE OF REVISIONS NO DATE DESCRIPTION BY 3 2 8/08/16 CITY COMMENTS CMS 1 A/13/'6 COMMENTS CMS 0 4/C5/16 PRELIM CC CMS SITE NAME: TUC VENTANA 2 SC SITE ADDRESS: 2150 E. TAN'GER'NE ROAD ORO VALLEY, AZ 85755 SEAL: FNsrEET TITLE: " POWER PLAN NORTHSNEE7 NUMBER: 22-x34- SCALE 1- = 80'-0- E-3 tt'xl7 SCALE 1- = 760'-0 8 40 0 D. CLIENT: NOTE: #6 COPPER WIRE AND GREATER SHALL BE (COPPER) THWN WIRE OR (COPPER) XHHW. NOTE: PRIOR TO RUNNING CONDUIT ROUTE - CONTRACTOR SHALL CONTACT THE VERIZON PROJECT MANAGER AND VERIFY THE EQUIPMENT CABINET LAYOUT CONFIGURATION AND ROUTE CONDUITS ACCORDINGLY. NOTE: PRE -CONSTRUCTION MEETING AND ELECTRICAL EASEMENT REQUIRED. EXISTING 50KVA ELECTRICAL SERVICE UTILITY-240/12OV, 1-PHASE, 3W NEW METER PER UTILITY COMPANY/NEC APPROVED, NEMA 3R, 100A, 120/24OV, 3W, 10 .oFAA-- I YO/AA-- O,Q AO n 9'tO NEW 100A, 240V, 10, N3R MILBANK METERED COMMERCIAL PEDESTAL WITH 16 POSITION SPACES, LOAD CENTER. REQUIRES F� A FOUR (4) JAW SOCKET PER APS SPECS. 0O OAA TO/ 240V I qY IUTY j p NEW 2.5" CONDUIT AND CONDUCTORS PER UTILITY COMPANY SPECS I � I >1ODA, 240V, 10 N313 11001t j I I_ I SERVICE RATED I _ _ _ _ _ I I MEB,MBJ G N /12 CU N I I I I U U j NEW I (711 a I 100/ BOND (2) 10' 1 I TO GROUND i NEW PANEL BOARD FACTORY MOUNTED IN GROUND RODS 10' METER PEDESTAL WITH INTEGRATED LOAD RING APART I CENTER. VERIFY LOCATION PRIOR TO L._._._._._._._._._._.J ROUGH -IN. NEW PANEL "A" 10KAIC ONE -LINE DIAGRAM NEW ELECTRICAL PANEL SCHEDULE PANELm LACATIOna PER PUN MONINC SURFACE NEW RATFIGSR 22KAIV/IOKAIC SERIES RATED VOLTAGE: 240 / 120 V 1e,301 W1n@ TOO A M9 Bus 100A CU LON) Dt50ePllaN EWT CONO CU ORND "M MIT a" OM OR NO. PNASE A LOAD AMPS FPAI C CN NO. CRE BRIM MtM REAR CU GRIND EMT CONO LOW DESCRFmON WISC WAN 100 2 1 0.0 0.0 2 50 2 a to 1-1/Y YISC GENERATOR PWC WISC CONT. ] 0.0 CA 4 a MSC CONT. 1115C REcnFIEN #1 I. to a 40 2 5 2e.7 1.5 a 20 1 12 12 3/4' RECMA= OPa W5C CCO. 12 7 2e.7 111 e 20 I 12 12 3/4' WECN (IAR4TSQ 1NM Y6C RECnFER 2 3/4' 12 12 20 2 a 13.7 0.0 10 15 1 12 12 3/4' MSC SPD MSC CONT. 12 11 13J 0.0 T2 12 MSC COAT. 13 0.0 0.0 14 is 1e NIPS PER PHASE (CODE LOW) I P110,!iE DEYYO RECEPTACLES WECWWMN. O 1.25% MISCELLANEOUS TOTAL VA 11.5 KVA • M O A Y 240 V U 240 V 10 413 51.7 CONTRACTOR TO NSTALL APPROVED Wool TIE ON ALL WAEO NEUTRAL OIRCFM SYMBOL USE 00 0.0 IIKLO 1750.0 0.0 9000.0 0.0 0.0 o.a a.o o.o 11550.0 PANEL SCHEDULE FAULT CALCULATIONS FAULT AVAILABLE AT THE SERVICE: 9,493 AMPS RMS SYVM PER UTILITY CHART SERVICE VOLTAGE: 120/240V, 1PH Panel A DISTANCE 5 Fast CONDUIT TYPE Nonwnductiw CONDUCTOR /1 Cu. Fault ANoeable L-L• 9,016A CODE LOAD SUMMARY PANEL 'A' ® 240V = 40.OA Poser Company: TOD Repneseniative: TBD Telephone /: TOD Telephone Company: Repneent "' Telephone /: Submit droWnge to Utility Company nePneeentatne as required in the General Notes included in the Electrical Drawings. Pre constnxtion meeting required before any work starts Two working dcys befcre you dig, CALL FOR THL BLUE STAKE! (602) 263-1100 OT 1 (800) STAKE -IT (782-5348) (OUTSIDE MARICOPA COUNTY) verizon/ 126 WEST GEMINI DRIVE TEMPE, ARIZONA 85293 PHONE 480.752.7230 IoSiinoDesign 16616 EAST PALISADES BOULEVARD UNIT /102 FOUNTAIN HILLS, ARIZONA 85268 PHONE 480.836.1701 FAX: 480.836.1004 WWW.SIINODESICN.COM ENGINEERING CONSULTANT: DRAWL\C APPROVALS (SIGNATURES) SITE ACQU'SITION/PROPERTY CONSTRUCT.ON MANAGER VER'.ZON W'.RELSS R' ENGINEER LANDLORD APPROVAL DRAWN 9�: JNGO CHECKED BY: CNS SCHEDULE OF REVIS'ONS NO DATE DESCR'PTIDN BY 3 2 8/08/16 CITY COVMLNTS CMS 1 L/'3/'6 COMV'N"S CMS 0 4/05/16 PRELIV CD CMS SITE NAME: TUC VENTANA 2 SC S'TE ADDRESS: 215C E. TA\CERAti ROAD ORO VALLEY, AZ 85755 SEAL SHEET TITLE: ONELINE DIAGRAM & PANEL SCHEDULE ONE -LINE DIAGRAM & PANEL SCHEDULE N.T.S. SHEET NUMBER 1 E-4 CLIENT' � GROUNDING PLAN LEGEND: I-AGBTINNED SOLID ALLOY 110 COPPER TOWER /ANTENNA BUS BAR BONDED TO MONOPOLE STEEL --c-- GROUND RING • EXOTHERMIC WELD OR IRREVERSIBLE HIGH -COMPRESSION CRIMP MECHANICAL CONNECTION vei izonf 126 WEST GEMINI DRIVE TEMPE. ARIZONA 85293 PHONE: 480.752.7238 DESIGN MANAGEMENT PROFESSIONAL• aSiinoDesign 16616 EAST PALISADES BOULEVARD UNIT 0102 FOUNTAIN HILLS, ARIZONA 85268 PHONE: 480.836.1701 FAX: 480.836.1004 WWW.SIINODESICN.COM ENGINEERING CONSULTANT. GENERAL NOTES: 1. THESE DRAWINGS REPRESENT THE GENERAL EXTENT AND ARRANGEMENT OF SYSTEMS, BUT ARE NOT TO BE CONSIDERED FABRICATION DRAWINGS. COORDINATE WITH OTHER TRADES, AND PROVIDE EACH SYSTEM COMPLETE, INCLUDING ALL NECESSARY COMPONENTS, FITTINGS AND OFFSETS. 2. INSTALL SYSTEMS SUCH THAT REQUIRED CLEARANCE AND SERVICE ACCESS SPACE IS PROVIDED AROUND ALL MECHANICAL AND ELECTRICAL EQUIPMENT, AND AROUND ANY COMPONENTS WHICH REQUIRE SERVICE ACCESS. 3. PROVIDE SUPPLEMENTARY STEEL AS REQUIRED FOR THE PROPER SUPPORT OF ALL SYSTEMS. DRAWNG APPROVALS 4. REFER TO G-2 FOR GROUNDING DETAILS. 5. ALL METALLIC SURFACES SHALL BE PREPARED PRIOR TO BONDING, COLD GALV. SPRAY SHALL BE USED ON ANY EXOTHERMIC WELD TO PREVENT CORROSION, SITE ACQUSTION/PROPERTY ANY AREA TO BE COLD GALV. SPRAY SHALL BE TAPED OFF PRIOR TO APPLICATION. CONSIRUCIION MANAGER CONSTRUCTION NOTES: 1. ANTENNA GROUND BUS BAR ATTACHED TO EXISTING PARAPET (TYP. OF 2), SEE DETAIL 5 ON SHEET G-2 2. BOND ANTENNA SUPPORT PIPE TO ANTENNA BUS BAR WITH #2 AWG SOLID TINNED BARE COPPER CONDUCTOR. 3. #2 AWG SOLID TINNED BARE COPPER CONDUCTOR FROM ANTENNA GROUND BUS BAR TO EQUIPMENT BUS BAR OR TO NEAREST BUILDING TERMINAL SYSTEM (V.I.F.). 4. EQUIPMENT GROUND BUS BAR ATTACHED TO PLATFORM. REFER TO DETAIL 1 ON SHEET G-2. 5. BOND EQUIPMENT GROUND BUS BAR TO THE NEAREST BUILDING STEEL OR EXISTING BUILDING TERMINAL SYSTERM. CONTRACTOR TO VERIFY AT FIELD. 6. BOND STEEL PLATFORM TO EQUIPMENT BUS BAR. 7. BOND EQUIPMENT CABINET TO EQUIPMENT BUS BAR PER MANUFACTURER'S SPECS (TYP. 2 LOCATION). 22%34• SCALE: 1/2• _ 1'-D- 11'x1T SCALE: 1/4' - 1'-0' NORTH 2 V 0 2' VERIZON W'.RELESS R' ENGNIER A LANDLORD A-ROVAL DRAWN BY: JNGO CHECKED 3Y: CVS SCIICDJLE OF REVISIONS NO DATE 7ESOR!DTION BY 3 2 B/CB/16 CITY COVMENTS CNS 1 4/13/16 COMNEN?S CNS 0 4/05/16 PRELIM C0 INS SITE NAME: TUC VENTANA 2 SC SITE ADDRESS: 2150 F. TANCERAF ROAD ORD VALLEY, AZ 85755 SEAL: SHEET TITLE: GROUNDING PLAN SIEE7 NL'V9E1 : 1 G-1 COAX CABLE GROUNDING KEYED NOTES: ® GROUND LUG KEYED NOTES:® CLIENT: 1 5 6 7 1. #2 AWG STRANDED Cu WIRE WITH GREEN, 60OV, THWN INSULATION OR BLACK MARKED AS REQUIRED BY NEC 1. NUT 2. LOCK WASHER 23 ■ verizon✓ 2. GROUND BAR ON EXTERIOR CABINET OR COAX H—FRAME 3. FLAT WASHER 3. #2 AWG SOLID BARE TINNED COPPER GROUND CONDUCTOR 4. BOLT TO BUILDING STEEL COLUMN OR MASTER GROUND BAR 5. BURNDY GROUND LUG (SEE TABLE FOR 8 SIZE AND MODEL) 126 WEST DRIVE TEMPI- AARZONA185293 6. HEAT SHRINK (CLEAR) 4 PHONE 480.752.7238 1 7. GROUNDING CONDUCTOR DESIGN MANAGEMENT PROFESSIONAL• 8. GROUND BUS BAR OR METALLIC BONDING SURFACE 9 aSiinoDesign 9. BURNDY 2—HOLE LUG W/ LONG rul BARREL FOR #6 AWG STRANDED 10. BARE WIRE TO BE NO—OXED AT BOTH 16616 EAST PALISADES BOULEVARD 102 UNrr ,ARIZONA z ENDS FOUNTAIN HILLS,85268 11. HEAT SHRINK FAX: PE480836.1004� O O mo 00O 12. #6 AWG THHN COPPER WIRE WWW.SIINODESIGN.COM ENGINEERING CONSULTANT: Cc) OOO Q 0 [) O 00 WIRESIZEBURNDY LUG BOLT SIZ 6 AWG YA6C-2TC38 3 8 — 16 INIC S 3 BOLT 2 AWG SOLID YA3C-2TC38 3 8 — 16 NC S 3 BOLT 3 2 AWG A — — 16 INIC S 3 BOLT 14/U 2/0 AWG 7T7672= 646 — S 5 HULI AWU YA28-1111 EQUIP. GRND. BUS BAR DETAIL N.T.S. 1 GROUND LUG DETAIL I N.T.s.1 2 NOT USED I N.T.S. 3 NOT USED N.T.S. 4 DRAWING APPROVALS (S'ONATURES) ANTENNA GROUNDING KEYED NOTES: ® NOTE: ERICO CADWELD "MOLD TYPES" SHOWN HERE ARE EXAMPLES. 1. RF TRANSMISSION LINES (COAX) FROM ANTENNA CONSULT WITH PROJECT MANAGER OR CONSTRUCTION MANAGER STE ACQJ'SiTON/PROPRTY 2. V COAX JUMPER FROM ANTENNA FOR SPECIFIC MOLDS TO BE USED FOR THIS PROJECT. 3. CONNECTOR WEATHERPROOFING KIT CONSTRUCTION MANACER 4. ANDREW "SUREGROUND" GROUND KIT (TYP.), REFER TO DETAIL 6023 FOR WEATHERPROOFING DETAILS 5. ANTENNA CABLE TO SHELTER (TYP.) 6. #6 AWG THHN COPPER CONDUCTOR 7. TINNED SOLID ALLOY 110 COPPER ANTENNA GROUND BUS BAR vERzoN WIRELESS R ENcw[Ee (OPTIONAL BOND DIRECTLY TO TOWER STEEL WITH ANGLE LANDLORD APPRDVAL ADAPTER IF NO ANTENNA BUS BAR IS AVAILABLE) TYPE VS TYPE TA TYPE HS TYPE SS TYPE PT DRAWN BY: .NCO 1 CHECKED BY; CMS SCdED'J;E OT REVISIONS NO DATE DESCRIPTION BY 3 ' 1 4 i NOTE• ; ; I I 5 ;AND TYPE GT TYPE HS TYPE XA TYPE VS TYPE YA-2 2 B/CB/16 CITY COVUENTS CMS DO NOT INSTALL CABLE GROUND KIT AT A BEND 6 ALWAYS DIRECT GROUND 7 ° '. 1 e/13/'6 COMMENTS CMS 0 4/05/16 PRELIM CD CMS SITE NAME: DOWN TO GROUND BAR. TYPE 2—YA— TUC_VENTANA_2_SC ANTENNA GROUNDING DETAIL I N.T.S. 15 EXOTHERMIC WELD DETAIL N.T.S. 6 NOT USED N.T.S. % NOT USED I N.T.S. 8 WEATHERPROOFING KEYED NOTES: SIT' ADDRESS: 2150 E. TANGERINE ROAD 1. COAX ORD VALLEY, AZ 85755 2. COAX TO JUMPER CONNECTION (TYP.) 3. JUMPER (TYP.) 4. 3M SCOTCH SUPER 33+ VINYL SEAL ELECTRICAL TAPE (OR EQUIVALENT) 5. VAPOR WRAP SEALANT 5 4 1 SHEET TITLE: GROUNDING DETAILS SHEET NUMBER: WEATHERPROOF DETAIL N.T.S. I NOT USED N.T.S.10 NOT USED N.T.S.11 NOT USED N.T.S. I 12 G=2 OQOJPLLEY ARZo29 TOWN OF ORO VALLEY DEVELOPMENT & INFRASTRUCTURE SERVICES DEPARTMENT 11000 N. LA CANADA DRIVE, ORO VALLEY, AZ. 85737 PHONE: (520) 229-4800 FAX: (520) 742-1022 .�, www.orovalleyaz.gov/dis _001DED 19�a 1.2 GENERAL APPLICATION FORM Office OV Case #: 41114,6 If:; Application ❑ Type Major General Plan Amendment ❑ Final Plat, ❑ Rezoning/PAD Amendment ❑ Pre -Application ❑ Planned Area Development ❑ Zoning Verification11�' ❑ Conditional Use Permit ❑ Sign Criteria ❑ Zoning Code Amendment ❑ Sign - PAD Exemption ; ....................... ❑ Conceptual Site Plan ❑ Master Sign Program ❑ Conceptual Public Art ® Communication Facility — Tier 1 and 2 Minor ❑ Conceptual Architecture ❑ Communication Facility — Major ❑ Final Site Plan ❑ Revised Development Plan ❑ Conceptual Landscape Plan ❑ Other Subject Property Information: Address: 2150 E. Tangerine Road Parcel/Tax Code: 220-04-3240 Subdivision / Commercial Center Name: Oro Valley Marketplace Book / Page or Sequence Number: Lot Number(s) Legal Description: lot 13 of the amended final plat of Oro Vally marketplace a subdivision of Pima County, Arizona Section/Township/Range: Area of Property: Existing Land Use: Commercial Building Proposed Land Use: Commercial building Applicant Information: Applicant *: Name: Verizon Wireless Address: 126 W Gemini Dr Telephone: (480) 777-4336 Fax: Property Owner(s) if different from Applicant *: Name: VPOVM LLC Address: 2425 E Camelback Rd. Ste 750 Telephone: Fax: Consultant: Site Acquisition Name: Daniel Nies Address: 2035 E Gondola Ln Telephone: (602) 390-8887 Fax: Firm: City: Tempe Email: Firm: City: Phoenix Email: (Discipline) Firm: Insite Inc. * If more than one, attach list State: AZ Zip: 85283 State: AZ Zip: 85016 City: Gilbert State: AZ Zip: 85234 Email: nies@insite-inc.com r Project Description/Narrative: Verizon wireless is seeking zoning approval to allow a small cell communications facility at the Walmart at Oro Valley Marketplace. This small cell site will consist of two antennas and an equipment cabinet. The equipment cabinet will be located on the roof of the building and will have five sided screening so as to be completely hidden from view. The antennas will be face mounted on the building facade, one on the southwest comer, one on south east comer. Both antennas will be enclosed within five sided screening that will be painted and textured to match the existing building. hereby certify that I have read and examined this application and know the same to be true and correct. I am the owner of the property or the Owner's authorized representative, and if not the owner, I have obtained the owner's permission to perform stated work. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The approval of this application does not presume to give authority to violate or cancel the provisions of any other federal, state or local law for which this project may be subject to. Notice: It is the applicant/ownees responsibility to ensure all private rules and regulations (such as Covenants, Conditions & Restrictions (CC&R's)) of the subdivision and/or commercial center are adhered to. Contact your Home Owners Association or property management to determine applicable requirements. It is also the applicant's responsibility to coordinate with all outside agencies to secure their acceptance or clearance. Failure to do so may delay issuance of permits. See attached list of agencies. Paaea (lLQ Daniel Nies 4/29/2016 Applicant's Signature Print Name Date Important Note: All submittals received after 4:00 p.m. will be processed the next day Submittals will be rejected if: • Not folded using Pima County fold & collated; • There are missing items on the checklist unless otherwise approved by Planning Division Manager or Town Engineer. • Re -submittals cannot be accepted without a transmittal and a written narrative summary describing the purpose of submittal. 2 ver#Lnwireless Project Narrative Verizon Wireless is seeking the Town of Oro Valley's review and approval of a wireless communication site to be co -located on the existing Walmart building located in the Oro Valley Marketplace retail area, at 2150 E Tangerine Road. Verizon has areas where they do not currently have adequate cellular coverage to meet their customers' demands. The area around Tangerine Rd. is one such area. The proposed cellular site will provide data capacity for Verizon customers desiring to use their mobile devices in the area. Additionally, there is a Verizon Retail store located in Oro Valley Marketplace, which is another reason that Verizon wants to ensure there is adequate data capacity. This site will provide added capacity to an area with an approximate radius of between 500' and 1,000'. We had originally contacted Denise Hart, Vice President of Vestar who manages the marketplace, in April of 2014, requesting to collocate on an existing parking lot light pole, or rooftop of one of the retail buildings she manages. We had many, many months of negotiations, but in the end were unable to get them to move forward. In the meantime, Verizon entered into a Master License Agreement with Walmart on a national level, so we wound up moving over to the Walmart rooftop. This proposed small cell will consist of two antennas, face mounted onto the building; one mounted on the Southeast corner near the roofline, and the other mounted on the Southwest corner near the roofline. The antennas will be screened on all sides, and the screening will be painted and textured to match the existing building surface. The antenna installation will not protrude above the existing building's highest point. An equipment cabinet will be installed on the roof of the building, behind the parapet wall. The cabinet and RRU's shall be concealed by 5-sided screening to match the existing HVAC screening. The installation of this site will not substantially add to the visual mass of the building. The installation is compatible with the structure and surrounding area, as this area is a commercial area, consisting of retail and restaurants. I have included Verizon's Communication Plan with this submittal. It consists of existing sites, as well as proposed sites, within the area. Verizon currently has 8 Cell Sites and 2 proposed small cells within the Oro Valley/North Tucson area. The sites are depicted on the map provided, as well as geographic coordinates for each of them. Also included is a coverage map of the sites. In addition to this proposed small cell, the other location Verizon has targeted is proposed to be mounted onto a Town of Oro Valley street light pole, located within town right-of-way, along Innovation Park Dr. That site is currently undergoing a Tier II review by the Planning Department. This location also needs additional capacity for data use. Other than that, there are no further sites needed at this time, based on current engineering data. Many factors, such as population growth in the area, could impact this in the future, possibly resulting in additional solutions. 00)� Global RF SolutionsS' PREDICT, DETECT, PROTECT 1900 W. Chandler Blvd. Ste. 15-228 Chandler, AZ 85224 (480) 814-1393 www.grfs.net Evaluation of Human Exposure to Radio Freauencv Emissions Analysis of TUC-Ventana 2 SC Oro Valley, AZ SITE RESULTS: Site ID: N/A Site Name: TUC-Ventana 2 SC Date of Evaluation 04/21/2016 Site Evaluator (name): Harry Young Site Type Building Tower/Monopole XX Water Tower Address: 2150 E. Tangerine Road Oro Valley,, AZ 85755 GPS NAD83 I N 32 25 33.7 W 110 56 27.4 Site Compliant I Yes An analysis of this Communications Facility has been completed to determine if it is compliant with guidelines set forth by the Federal Communications Commission (FCC) with regards to maximum human exposure limits. This determination of FCC Compliance is applicable to all transmitting equipment at this location. Calculations of the proposed changes to this site have been performed using RoofView° MPE software. We have determined that the proposed changes will result in an insignificant increase to the overall RF environment. This site is compliant with FCC guidelines as proposed by Verizon Wireless. © 2016 Global RF Solutions 2 Provider's Communication Plan: TUC VENTANA 2 SC � wesr visroso IC LAf-ABERT 3HAf+1N0N-RD BC TUC OPEN w- PV c9=0 TUC LA-CANADA %a & 1 49r1b TUC LA-CANADA LAI TUC_EL-CONQUISTAD17R ft:50 % .W TUC CIRCLE-K TI if \fFRITANIA 9. Verizon Wireless Proprietary and Confidential WMTZMwireless Existing coverage a in the area before Small Cell %I r a e T 7 I ,i, M IRS" 440 • y"f 1' s t c 1 .. i �, ✓� Clr: BSPP (dBm ) :1 >= -15 > = -30 Wf >= -45 -60 ff}} -104 v. Verizon Wireless Proprietary and Confidential 2 Vef'/ZlMvoreless Existing coverage a in the area after Small Cell g ,. r ■ a 'T. e ° - ys Verizon Wireless Proprietary and Confidential 3 TEZ Or: RSRP (dBrri) >= -30 >= -45 >= -60 >= -75 >= -90 >= -104 Well-, On Fireless 1 _ � w 4 yYXAA I �" A + m low E Tom- Ventana 2 SC 150 E Tangerine Rd " 9 32° 25' 33;70' N ro Malley, AZ 85755 US 1100 5627 40"W FEW s �. Ventana 2 S 2150 E Tangerine Rd 320 25' 33.70" N Oro Valley, AZ 85755 US Mo 5 v' Ver ,AOnwireless for e � -v01 �r APPROVED BY, TC/P IleD rs� PZ PROJECT MANAGER VerIZOnwireiess Wntana 2 S 2150 E Tangerine Rd 320 25' 3&70"N Oro Valley, AZ 85755 US 1100 56 27-.40"W To rg e° D. z BEFORE SOUTH VIEW gr vl Y AFTER TA d e: v i XUE :-r d rl 0 .w two !' rt. T U C_Ve n t a n a_2_S C. I;' 2150 E Tangerine Rd 320 25' 33.70"N verl onw,reless. Oro Valley, AZ 85755 US 1100 56' 27.40"W forge 0 .0 ��41 BEFORE' SOUTH VIEW !.W L: �-Mrc-:,n VICINITY MAP z �O o �z 411�o�o TANGERINE SITE R m z Y Q Y m Z g � PALISADES RD NORTH DRIVING DIRECTIONS SUMMARY: FROM THE VERIZON OFFICES IN TEMPE: TAKE 1-10 SOUTH TO TUCSON. TAKE EXIT 240, TURN LEFT ONTO W. TANGERINE RD. TURN RIGHT ONTO N. INNOVATION MARHET DR. SITE IS ON THE LEFT ON THE ROOF TOP OF WAL MART BUILDING. GENERAL NOTES THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT AS SET FORTH IN THE CONSTRUCTION DRAWINGS, CONTRACT DOCUMENTS AND THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECT/ENGINEER OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF THE CONTRACTOR'S PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK UNLESS OTHERWISE DIRECTED. • TUC VENTANA 2 SC 2150 E. TANGERINE ROAD ORO VALLEY, AZ 85755 AP N NO. 220-04-3240 SITE LOCATION INFORMATION SITE NAME: TUC-VENTANA-2-SC SITE ADDRESS: 2150 E. TANGERINE ROAD ORO VA -LEY, AZ 85755 APN NUMBER: 220-04-3240 CENTER OF LATITUDE: 32' 25' 33.7" N (NAD 83) BUILDING LONGITUDE: 110' 56' 27.4" W (NAD 83) COORDINATES: ELEVATION: 2 671.0' (AMSL) (NAVD 88) SECTOR "A" LATITUDE: 32' 25' 32.0" N (NAD 83) COORDINATES: LONGITUDE: 110' 56' 30.4" W (NAD 83) SECTOR "B" LATITUDE: 32' 25' 31.8" N (NAD 83) COORDINATES: LONGITUDE: 110' 56' 24.4" W (NAD 83) CURRENT ZONING: TBD APPLICANT: VERIZON WIRELESS 126 WEST GEMINI DR. TEMPE, AZ 85283 CONTACT: DAMON GAUTHIER PHONE: (602) 291-5983 PROPERTY OWNER: TOWN OF ORO VALLEY OWNER CONTACT: TBD CONTACT: PHONE: CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORT( NOT CONFORMING TO THESE CODES. 2012 INTERNATIONAL BUILDING CODE (IBC) 2011 NATIONAL ELECTRICAL CODE (NEC) ANSI/EIA-222—G STRUCTURAL STEEL STANDARDS FOR STEEL ANTENNA TOWERS AND SUPPORTING STRUCTURES STANDARD LOCAL BUILDING CODE(S) CITY AND/OR COUNTY ORDINANCES JURISDICTION: TOWN OF ORO VALLEY Two working days before you dig, CALL FOR THE BLUE STAKE! 1 (602) 263-1100 or 1 (800) STAKE -IT (782-5348) (OUTSIDE MARICOPA COUNTY) PROJECT TEAM CLIENT: VERIZON WIRELESS 126 WEST GEMINI DRIVE TEMPE, ARIZONA 85283 CONSTRUCTION MANAGER: DAMON GAUTHIER MOB;LE: (602) 291-5983 RF ENGINEER: SYED NAOVI REAL ESTATE: JAMISON TYLER MOBILE: (480) 777-4336 REAL ESTATE INSITE INC. CONSULTANT: 2035 E. GONDOLA LN. GILBERT, AZ 85234 CONTACT: CHRISTINE TUCKER MOBILE: (480) 586-5180 TUCKER@INSITE-INC.COM A&E DESIGN SAND DESIGN MANAGEMENT 16616 EAST PALISADES BLVD, SUITE 102 PROFESSIONAL: FOUNTAIN HILLS, ARIZONA 85268 CONTACT: CHRIS M. SIINO, MBA, MSTL, PMP MOBILE: (602) 672-4311 FAX: (480) 836-1004 CIVIL ENGINEERING PNP ENGINEERING INC CONSULTANT: CONTACT: YONG-JOONG KANG, PE MOBILE: (949) 351-5020 EE CONSULTANT: EE LLC CONTACT: LOREN PRIEST SHEET INDEX SHEET N0. SHEET DESCRIPTION T-1 TITLE SHEET GN-1 GENERAL NOTES GN-2 GENERAL NOTES LS-1 SITE SURVEY LS-2 SITE SURVEY A-1 OVERALL SITE PLAN A-2 ENLARGED SITE PLAN A-3 ELEVATION A-4 CCNSTRUCTION DETAILS E-1 ELECTRICAL NOTES E-2 ELECTRICAL NOTES E-3 POWER PLAN E-4 ONELINE DIAGRAM & PANEL SCHEDULE G-1 GROUNDING PLAN G-2 GROUNDING DETAILS ACCESSIBILITY DISCLAIMER I PROJECT DESCRIPTION THE PROPOSED PROJECT IS AN UNOCCUPIED TELECOMMUNICATIONS FACILITY AND IS NOT TO BE ACCESSED BY THE GENERAL PUBLIC. THIS FACILITY IS EXEMPT FROM DISABLED ACCESS REQUIREMENTS PER IBC 1103.2 9 LISTED AS AN EQUIPMENT SPACE. THE PROJECT CONSISTS OF THE INSTALLATION OF (2) NEW ANTENNAS TO AN EXISTING BUILDING AND BEHIND RFP SCREENS. IN ADDITION, INSTALLATION OF (1) NEW EQUIPMENT CABINET ON (1) NEW NON —PENETRATION PLATFORM ON EXISTING BUILDING ROOF TOP AND (2) NEW NON—PENTRATRATION MOUNT TO SUPPORT (2) NEW RRHs. THIS PROJECT DOES NOT INCLUDE WATER OR SEWER. THIS PROJECT INCLUDES PERMANENT TELEPHONE AND ELECTRICAL CONNECTIONS. DEVELOPMENT AND CONSTRUCTION OF THIS PROJECT WILL COMPLY WITH ALL APPLICABLE CODES AND CRDINANCES. verizon✓ 126 WEST GEMINI DRIVE TEMPE, ARIZONA 85293 PHONE: 480.752.7238 DESIGN MANAGEMENT PROFESSIONAL: ® SHnoDesign 16616 EAST PALISADES BOULEVARD UNIT #102 FOUNTAIN HILLS, ARIZONA 85268 PHONE 480.836.1701 FAX: 480.836.1004 WWW.SIINODESIGN.COM ENGINEERING CONSULTANT: DRAWING APPROVALS (SIGNATURES) SITE ACQUISITION/PROPERTY CONSTRUCTION MANAGER VERIZON WIRELESS RF ENGINEER LANDLORD APPROVAL DRAWN BY: JNCO CHECKED BY: CMS SCHEDULE OF REVISIONS NOI DATE I DESCRIPTION IBY 1 4/13/16 COMMENTS CMS 0 4/05/16 PRELIM CD CMS SITE NAME: TUC VENTANA 2_SC SITE ADDRESS: 2150 E. TANGERINE ROAD ORO VALLEY, AZ 85755 SEAL: SHEET TITLE: TITLE SHEET SHEET NUMBER: T-1 V/CINITY N.T.S. 9 dfAP i o G F� ���O.r AZ r RO o O SN NGEfi\NE PRO.ECT o m � PALISADES RD SURVEY DATE 03/23/2016 BASIS OF BEARING BEARINGS SHOWN HEREON ARE BASED UPON U.S. STATE PLANE NAD83 COORDINATE SYSTEM ARIZONA STATE PLANE COORDINATE CENTRAL ZONE, DETERMINED BY CPS OBSERVATIONS. BENCHMARK PROJECT ELEVATIONS ESTABLISHED FROM CPS DERIVED ORTHOMETRIC HEIGHTS BY APPLICATION OF NGS 'GEOID 12A' MODELED SEPARATIONS TO ELLIPSOID HEIGHTS DETERMINED BY OBSERVATIONS OF THE 'SMARTNET' REAL TIME NETWORK. ALL ELEVATIONS SHOWN HEREON ARE REFERENCED TO NAVD88. FLOOD ZONE THIS PROJECT APPEARS TO BE LOCATED WITHIN FLOOD ZONE "X". AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN ACCORDING TO FEDERAL EMERGENCY MANAGEMENT AGENCY FLOOD INSURANCE RATE MAP(S), MAP ID #04019C109OL, DATED 06/16/2011. UTILITY NOTES SURVEYOR DOES NOT GUARANTEE THAT ALL UTILITIES ARE SHOWN OR THEIR LOCATIONS ARE DEFINITE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND DEVELOPER TO CONTACT BLUE STAKE AND ANY OTHER INVOLVED AGENCIES TO LOCATE ALL UTILITIES PRIOR TO CONSTRUCTION. REMOVAL, RELOCATION AND/ OR REPLACEMENT IS THE RESPONSIBILITY OF THE CONTRACTOR. SURVEYOR'S NOTES SURVEYOR HAS NOT PERFORMED A SEARCH OF PUBLIC RECORDS TO DETERMINE ANY DEFECT IN TITLE ISSUED. THE BOUNDARY SHOWN HEREON IS PLOTTED FROM RECORD INFORMATION AND DOES NOT CONSTITUTE A BOUNDARY SURVEY OF THE PROPERTY. ALL DISTANCES SHOWN HEREON ARE GRID DISTANCES. LESSOR'S LEGAL DESCRIPTION THE LAND REFERRED TO HEREIN BELOW IS SITUATED IN THE COUNTY OF PIMA, STATE OF ARIZONA, AND IS DESCRIBED AS FOLLOWS: LOT 13 OF THE AMENDED FINAL PLAT OF ORO VALLEY MARKETPLACE, A SUBDIVISION OF PIMA COUNTY, ARIZONA ACCORDING TO THE MAP OR PLAT THEREOF OF RECORD IN THE OFFICE OF THE COUNTY RECORDER OF PIMA COUNTY, ARIZONA IN BOOK 64 OF MAPS AND PLATS AT PAGE 42 THEREOF. SCHEDULE "B" NOTE REFERENCE IS MADE TO THE TITLE REPORT ORDER #AZ-FCOP-IMP-N/A-1-16-51005101, ISSUED BY FIDELITY NATIONAL TITLE INSURANCE COMPANY, DATED FEBRUARY 4, 2016. ALL EASEMENTS CONTAINED WITHIN SAID TITLE REPORT AFFECTING THE IMMEDIATE AREA SURROUNDING THE LEASE HAVE BEEN PLOTTED. 1. ITEM NUMBERS 1-7, 9-11. 14. 19. 21, 25, 29. 31. 32, 34 AND 36-41 ARE NOT SURVEY MATTERS, OR HAVE NO EFFECT IN THE AREA OF THIS SURVEY. 2. ITEM NUMBERS 8, 12, 17. 18, 22-24, 26, 27, 30, 33, AND 35 ARE SHOWN AND NOTED ON THE SURVEY DRAWING 3. ITEM NUMBERS 13. 15. 16, 20. 28 ARE ALL BLANKET IN NATURE OVER THE ENTIRE PARCEL AREA. THE SURVEYORS OPINION IS THAT NO SCHEDULE "B"ITEMS PROVIDED BY SAID REPORT AFFECT THE PROPOSED WIRELESS FACILITY PREMISES SHOWN HEREON. LEGEND AP ASPHALT TELECOMMUNICATIONS ANTENNA CURBUNES BLDG TOP OF BUILDING ED AIR CONDITIONING UNIT CONCRETE LIMITS CONIC EDGE OF CONCRETE 0- UTILITY MANHOLES EXISTING BUILDINGS D/W ACCESS DRIVEWAY 0° UTILITY METER PARKING STRIPES EP EDGE OF PAVEMENT 7x FIRE HYDRANT W W WATER UNES FC LP FACE OF CURB LIGHT POLE POWER POLE SS 55 SEWER LINES NG NATURAL GRADE # LIGHT POLE — GAS GAS — GAS LINES R/W RIGHT OF WAY ® � ELECTRICAL TRANSFORMER E E ELECTRIC LINES SW SIDEWALK POSITION OF — GEODETIC COORDINATES F/0— F/0— FIBER OPTIC LINES V ROOF VENT SPOT ELEVATION STREET CENTERLINES DR © ROOF DRAIN SKYLIGHT .°'i" pd WATER CONTROL VALVE - - SUBJECT PROPERTY LINE Is TREES © GAS VALVE -_______-__ ADJACENT PROPERTY LINE - EASEMENT LINES ELECTRIC WATER METER TRANSFORMEF — — / 30 EASEMENT DKT. 13360. PG. 146 — — — — — — — — — — — — —` — — — — ENT ——��KT.07786,AD uPGM 966 CLIENT: ■ W s_ w— --55 = _ — -� UTILITY VAULT,/ venzpon :"57 126 WEST GEMINI DRIVE _ - — — — — — — �®� �® — — — . — — — — —— — ❑ — — — — — — �� AA TEMPE ARIZONA 85283 PHONE: (480) 752-7238 1'1� 00 ® ® ®� ® ❑ ❑ ❑ ® ® \ DESIGN MANAGEMENT PROFESSIONAL: D ' • I fTER\ / \ I 1 I XCLEAN DO ® ® ® ® ® ® ® ® ® ® O I /\ N N N N N❑ N N NON ® P—M I �SiinoDesign N ® ® ® ® ® ® ® ® ® STORM DRAIN PJT 0 0 ® ® 0 0 0 190 8 STORM DRAIN M All 1 1 LI'J ® ® ® ® ® ® ® ® ® ® ® I I 16616 EAST PALISADES BLVD. SUITE 102 FOUNTAIN HILLS, ARIZONA 85268 I N N BACK -FLOW / I I I PHONE: (480) 836-1701 ® ® ® ® ® ® ® ® ® ® ❑ ® PREVENTER I I I I FAX: (480) 836-1004 y wwwsdlIc.bz ® N ® A I SURVEYING CONSULTANT: �� 01 w� N N N N N N N N N N N N N N N N N N N N N N N N /I bit Z I N N N N N N N N N N x ® ® ® ® ® ® ® ® ® ® / I I III _ I 410 EAST SOUTHERN AVENUE ❑ . ❑ 0 O ❑ ❑ ❑ ® / / I — - III I TEMPE, ARIZONA 85282 (480)659-4072 El El ❑ ❑ IN® DRAWING APPROVALS (SIGNATURES) SE F DETAIL I I SITE ACQUISITION/PROPERTY I / — —C ON StZU L S - 2 CONSTRUCTION MANAGER I I - r rn -- O1 4 I i I VERIZON WIRELESS RF ENGINEER PNL_- LANDLORD APPROVALcn o _[_ m I — — — --ttlI-- — — — c7 / c1 II I i =_I_.. I DRAWN BY: RC CHECKED BY. MF SCHEDULE OF REVISIONS J/ J zJ z I II J NO DATE DESCRIPTION BY a a V N/ N A / l 2 04/07/16 ROOF SHOTS (A) RC 1 04/05/16 COMMENTS CK PARCEL 0 03/31/16 PRELIM SUBMITTAL RC SITE NAME: /WATER TUC VENTANA 2 SC # 17 EASEMENT / DKT. 13077. PG. 1 j / / /�/ / SITE ADDRESS: DKT. EASSEME�NTT 2150 E. TANGERINE ROAD fD/W p�p`p ORO VALLEY, AZ 85755 SEAL: BOOK P62. PC. 19 01 9. D/W # 27 EASEMENT # 24 EASEMENT 07 / DKT. 13303, PG. 2242 / SHEET TITLE: DKT. 13222, PG. 835 9 \ \ / D18 KT EASEMENT 3091. PG. 1z4 / GRAPHIC SCALE ,w SITE SURVEY # 22 EASEMENT IN P'EE1') ns-DKT. 13 23 E EMPG.ENT 44 1 inch - 60 RDKT. 13149, PG47 1 OVERALL SITE PLAN KEYED NOTES: CLIENT: 1. EXISTING PARKING 2. EXISTING ELECTRIC TRANSFORMERS 3. EXISTING SKY LIGHT (TYP.) 4. EXISTING BUILDING TO BE UTILIZED 5. EXISTING BUILDING ENTRANCE. NEW LESSEE 24—HR BUILDING ACCESS ENTRANCE 6. EXISTING ROOF HATCH. NEW LESSEE 24—HR ROOF ACCESS 7. EXISTING HVAC (TYP.) 8. EXISTING PIPE (TYP.) 9. EXISTING SOLAR SHADE CANOPY 10. EXISTING EASMENTS (SEE SURVEY SHEET LS-1) 11. NEW ROOF MOUNTED CONDUITS FOR FIBER & ELECTRIC RUN, FINAL ROUTE TO BE DETERMINED. 12. NEW CABLE TRAY FOR HYBRID RUNS 13. NEW ROOF PAD ACCESS TO EQUIPMENT CABINET LOCATION (TYP.) Two working cloys before you dig, CALL FOR THE BLUE STAKE! 1 (602) 263-1100 or 1 (800) STAKE —IT (782-5348) (OUTSIDE MARICOPA COUNTY) 13LDG TOP OF BUILDING ----0 STREET LIGHT CLF CHAIN LINK FENCE V FIRE HYDRANT CONIC CONCRETE cM POWER POLE D/W ACCESS DRIVEWAY POSITION OF FC FACE OF CURB GEODETIC COORDINATES NG NATURAL GRADE SPOT ELEVATION R/W RIGHT OF WAY Is TREES pd WATER CONTROL VALVE 4 NEW ANTENNA GROUND ROD V EXISTING ANTENNA rr GROUND BUS BAR Q REVISION ■ MECHANICAL GRIND. CONN. O CONSTRUCTION KEYED NOTE • CADWELD ® GROUND ACCESS WELL DETAIL REFERENCE (K] ELECTRIC BOX TELEPHONE BOX ELEVATION REFERENCE LIGHT POLE SECTION REFERENCE GRAVEL GROUT OR PLASTER ® PLYWOOD o (E) BRICK SAND (E) MASONRY ® WOOD CONT. 0 CONCRETE WOOD BLOCKING ® STEEL EARTH 0 0 0 0 0 W —W —W GAS — GAS — GAS O/H— 0/I+— O/H —E—E—EE— F/0— F/0 F/0 FE— FB— FB— FIB — OVERALL SITE PLAN CHAIN LINK FENCE CURBUNES WATER LINES GAS LINES OVERHEAD LINES ELECTRIC LINES (E) FIBER OPTIC LINES (N) FIBER OPTIC LINE STREET CENTERLINES RIGHT OF WAY LINES LEASE AREA LIMITS MAJOR CONTOUR INTERVAL MINOR CONTOUR INTERVAL ® L_ 13 ® ® ® ® ❑® ® s ❑ ® I I I ®❑ ® ® ® ® ® ® ® ® S ■ 0 ■ w El 0 ® ® ® ■ ® ® ® ®� ® ® I �.. ®❑ ® ® 12 ® E® 8 ® ® ®Fl® ® $ 00 ❑ O O ❑ ® ® l - a J 123 r 1 �\ A-2 .� ACCESS _ .. APNN: 2220--04-3240 1 — ZONING: TBD — I --r 9 — USE: COMMERCIAL T � • Ll\-- —', 9 10 ACCESS PROPERTY LINE I =/ C9 �a i venzon✓ 126 WEST GEMINI DRIVE TEMPE. ARIZONA 85293 PHONE: 480.752.7238 - 111SHnoDesign 16616 EAST PALISADES BOULEVARD UNIT /102 FOUNTAIN HILLS, ARIZONA 85268 PHONE 480.836.1701 FAX: 480.836.1004 WWW.SIINODESIGN.COM ENGINEERING CONSULTANT: 1 NORTH 22•x34: SCALE: ,• _ 80 11'x17� SCALE: 1' _ 160'-0" 8 0' DRAWING APPROVALS (SIGNATURES) SITE ACQUISITION/PROPERTY CONSTRUCTION MANAGER VERIZON WIRELESS RF ENGINEER LANDLORD APPROVAL DRAWN BY: JNGO CHECKED BY: CMS SCHEDULE OF REVISIONS NO DATE DESCRIPTION BY 3 2 1 4/13/16 COMMENTS CMS 0 4/05/16 PRELIM CD CMS SITE NAME: TUC VENTANA 2 SC SITE ADDRESS: 2150 E. TANGERINE ROAD ORO VALLEY, AZ 85755 SEAL SHEET TILE: OVERALL SITE PLAN SHEET NUMBER: A-1 ANTENNA PLAN KEYED NOTES: ® ENLARGED SITE PLAN KEYED NOTES: ® 8. NEW ANTENNA FLUSH MOUNTED ON EXISTING BUILDING (NEW NOTE: CLIENT:: 1. NEW (1) ANTENNA PER SECTOR, TOTAL OF (2) SECTORS MOUNTED TO EXISTING BUILDING BEHIND NEW RFP SCREENING, REFER STRUCTURAL ANALYSIS & DRAWINGS BY OTHERS 0 28'-0" RAD CENTER. 2. EXISTING BUILDING PARALET ANTENNAS TO BE CONCEALED BY RF FRIENDLY SCREENING 1. LINE OF EXISTING BUILDING. PAINTED TO MATCH EXISTING BUILDING (TYP. OF 2), REFER 2. EXISTING HVAC (TYP.) STRUCTURAL CALCULATIONS BY OTHERS. 3. EXISTING ROOF VENT PIPE (TYP.). 9. NEW ACCESS PATH FROM ROOF HATCH TO EQUIPMENT CABINET 4. NEW ROOF MOUNTED CONDUIT FOR POWER & FIBER RUNS. 10. EXISTING PROPERTY LINE 1. NEW FRP SCREENING SHALL BE PAINTED TO MATCH BUILDING COLOR. 2. REFER STRUCTURAL CALCULATIONS FOR PLATFORM AND SCREENING DETAILS verizon✓ 3. NEW CABLE TRAY FOR HYBRID RUNS 4. NEW VERTICAL RISER OF CABLE LADDER (INSIDE VERTICAL RISER OR SIMILAR, SEE DETAIL 11 ON SHEET A-4 FINAL POWER & FIBER SOURCES TO BE DETERMINED, SEE 11. EXISTING ROOF SURFACE DETAIL 2 ON SHEET A-4 12. NEW (1) ANTENNA PER SECTOR, TOTAL OF (2) SECTORS 5. NEW EQUIPMENT CABINET (CHARLES CUBE) MOUNTED ON NEW MOUNTED TO EXISTING BUILDING 0 28'-0" RAD CENTER. REFER PLATFORM (PLATFORM AND CABINET TO BE CONCEALED BY 5 STRUCTURAL CALCULATIONS FOR ANTENNA MOUNT DETAILS 126 WEST GEMINI DRIVE TEMPE. ARIZONA 85293 PHONE 480.752.7238 DESIGN MANAGEMENT PROFESSIONAL: SIDED SCREENING TO MATCH EXISTING HVAC SCREENING). 13. NEW VERTICAL RISER OF CABLE LADDER (INSIDE VERTICAL REFER STRUCTURAL CALCULATIONS BY OTHERS. RISER OR SIMILAR, SEE DETAIL 11 ON SHEET A-4 ®S i i n o D e s i n 2 3 3 META 260' 4 1 Q O 6. NEW CABLE TRAY FOR HYBRID CABLE RUNS, SEE DETAIL 1 ON SHEET A-4. 7. NEW RRH ON NEW MOUNT (NEW MOUNT TO BE CONCEALED BY 5 SIDED SCREENING TO MATCH EXISTING HVAC SCREENING) (TYP. OF 2). REFER STRUCTURAL CALCULATIONS BY OTHERS g 16616 EAST PALISADES BOULEVARD UNIT 0102 FouNraN HILLS, A 8sz68 PHONE 480.836.1.836.1701 FAX: 480.836.1004 WWW.SIINODESIGN.COM ENGINEERING CONSULTANT: I I El - 1 4 v 2 I I I L---_J I 10 I II 1 NEW ANTENNA LAYOUT N.T.S. FJ ANTENNA SECTION KEYED NOTES: ® 1. NEW ANTENNA (TYP. OF 2). 2. NEW PIPE AND SUPPORT KITS. f 3. EXISTING BUILDING. J - 4 NEW FRP SCREENING (TYP.) 5. RRH (BEYOND) 1 I I 3 2 I I I I I (PLATFORM SEE NOTE 2 ____ I I DRAWING APPROVALS (SIGNATURES) SITE ACQUISITION/PROPERTY 4 4 I I I CONSTRUCTION MANAGER RAD CENTER I 28'-0" A.G.L. I N 2 0 I I �z I I J W L-___J a N ° \ 6 Eci VERIZON WIRELESS RF ENGINEER LANDLORD APPROVAL DRAWN BY: JNGO CHECKED BY: CMS SCHEDULE OF REVISIONS I , NO DATE DESCRIPTION BY I 5 3 I 2 1 t, I 1 4/13/16 COMMENTS CMS 1 NOTES L — — — — — — NEW FRP SCREENING SHALL 1 I 6 0 4/05/16 PRELIM CD CMS SITE NAME: TUC VENTANA 2 SC BE PAINTED TO MATCH BUILDING COLOR. I 7 1 I I 2'-7" I 11 13 r 1 13 N SITE ADDRESS: 2150 E. TANGERINE ROAD ORO VALLEY, AZ 85755 NOT USED N.T.S. 2 NOTE 11.9" CONTRACTOR TO VERIFY FOR FINAL RF DATA SHEETS WITH CONSTRUCTION MANAGER PRIOR TO ANY CONSTRUCTION. SEAL: NEW ANTENNA & HYBRIFLEX CABLE TABLE SECTOR AZIMUTH q (FT) LINE SIZE OF �FT)H COAX TYPE ALPHA 150' 28'-0" 4 7/8" ±590' HYBRIFLEX BETA 260' 28'-0" 4 7/8" ±32' HYBRIFLEX 0 I 't I -- __ PA IS7 U�- 12 8 04 �— ] iv 4'-0" 0 n I 2'-0" N 1 SHEET TITLE: ' ENLARGED SITE PLAN I NORTH SHEET NUMBER: NEW ANTENNA & COAXIAL CABLE SPECS. N.T.S. 3 ENLARGED SITE PLAN 22'x34' SCALE:'/2' _ 1'-0• 11%17' SCALE: 1/4' a 1'-0' 2 1 0 2' 4 A'Z ELEVATION KEYED NOTES: 1. EXISTING BUILDING 2. EXISTING HVAC BEYOND (TYP.) 3. LINE OF EXISTING ROOF 4. NEW (1) ANTENNA PER SECTOR, TOTAL OF (2) SECTORS MOUNTED TO EXISTING BUILDING ® 28'-0" RAID CENTER 5. NEW EQUIPMENT CABINET MOUNTED TO NEW NON —PENETRATION PLATFORM (PLATFORM AND CABINET TO BE CONCEALED BY 5 SIDED SCREENING TO MATCH EXISTING HVAC SCREENING) 6. NEW RRHs MOUNTED ON NEW MOUNT (TRIPOD MOUNT TO BE CONCEALED BY 5 SIDED SCREENING TO MATCH EXISTING HVAC SCREENING) (TYP. OF 2) 1. NEW FRP SCREENING SHALL BE PAINTED TO MATCH BUILDING COLOR. Z lL z 0 ¢ D 3 �¢ W Z Z Z �zUJI U 0 H- z 0 0¢ mw 0z I N M I I n I I II —�I---I----- I --L----- U z 0 az m O O Z F a0 N U_ J X w 0¢ LL O Z 0 ^¢ o •I F � � M ¢ -H fM _ ¢ Z ----------1— —.1.--Z ¢ Q �++ z wz w U Z 0 z LL Outdoor Wing ¢ ¢ 0 w3 w 0 Z D_ O I w co 0 j1 N I'1 CLIENT: verizon✓ 126 WEST GEMINI DRIVE TEMPE, ARIZONA 85293 PHONE: 480.752.7238 ffillSiinoDesign 16616 EAST PALISADES BOULEVARD UNIT J102 FOUNTAIN HILLS, ARIZONA 85268 PHONE 480.836.1701 FAX: 480.836.1004 WWW.SIINODESIGN.COM ENGINEERING CONSULTANT: DRAWING APPROVALS (SIGNATURES) SITE ACQUISITION/PROPERTY CONSTRUCTION MANAGER VERIZON WIRELESS RE ENGINEER LANDLORD APPROVAL DRAWN 8Y: JNGO CHECKED BY: CMS SCHEDULE OF REVISIONS NO DATE DESCRIPTION BY 3 2 1 4/13/16 COMMENTS CMS 0 4/05/16 PRELIM CD CMS SITE NAME: TUC VENTANA 2 SC SITE ADDRESS: 2150 E. TANGERINE ROAD ORO VALLEY, AZ 85755 SEAL SHEET TITLE: ELEVATION SHEET NUMBER: 1 A-3 SOUTH ELEVATION 22•z34• SCALE: 1/8' - 1'-0' „•X17• SCALE: 1/16• - 1'-0• 8 6 4 2 0 8' OPO�P��EY gRi�o�9 �1 ► i ► 1 .1 ,FOUNDED A91 as Town of Oro Valley Development and Infrastructure Services Department September 19, 2016 Daniel Nies Insite Inc. 2035 E. Gondola Lane Gilbert, AZ 85234 via email: nies .insite-inc.com Re: Verizon Telecommunication Facility 2150 E. Tangerine Rd. Tier 1 Wireless Communication, OV1601138 Dear Daniel, Thank you for submitting a Tier 1 Wireless Communication Facility for Verizon Wireless. It has been a pleasure working with you on this project. The Town has administratively approved the application. The next step is to submit building plans for review and approval. Please do not hesitate to contact me with any questions or concerns. Best, Robert Kirschmann Planner Oro Valley, it's in our nature. 11000 N. La Canada Drive Oro Valley, Arizona 85737 www.orovalleyaz.gov I phone: (520) 229-4800 1 fax: (520) 742-1022