Loading...
HomeMy WebLinkAboutOV1802194oPO�P�IEY qR?0 TOWN OF ORO VALLEY COMMUNITY DEVELOPMENT & PUBLIC WORKS DEPARTMENT 11000 N. LA CANADA DRIVE, ORO VALLEY, AZ. 85737 PHONE: (520) 229-4800 FAX: (520) 742-1022 www.orovalleyaz.gov �OOVDED A9' 1.2 GENERAL APPLICATION FORM ice Application ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Tvpe: Major General Plan Amendment Rezoning/PAD Amendment Planned Area Development Conditional Use Permit Zoning Code Amendment Conceptual Site Plan Conceptual Public Art Conceptual Architecture Final Site Plan Conceptual Landscape Plan ®' `� ❑ Final Plat rjs� ❑ Pre -Application A�%k3 ❑ Zoning Verification 022011 ❑ Sign Criteria 'RJ , . ❑ Sign - PAD Exemption ❑ Master Sign Program d Communication Facility — Tier 1 and 2 Minor ❑ Communication Facility — Major ❑ Revised Development Plan ❑ Other Subject Property Information: Address: 11167 N. Oracle Rd., Oro Valley, 85737 Parcel/Tax Code: N/A, ROW Subdivision / Commercial Center Name: Book / Page or Sequence Number: Lot Number(s) Legal Description: Lessor's Legal Description on Site Plan page LS-1 Section/Township/Range: T12S, R14E, S5 Area of Property: Existing Land Use: ADOT Right -Of -Way Proposed Land Use: Installation of Verizon Wireless Communication Facility Applicant Information: * If more than one, attach list Applicant *: Name: Michelle Lamoureux Firm: Pinnacle Consulting. Inc.. c/o Verizon Wireless Address: 1426 N. Marvin St., #101 City: Gilbert State: AZ Zip: 85233 Telephone: 480 664 9588 x 230 Fax: Email: Michelle.Lamoureux@pinnacleco.net Property Owner(s) if different from Applicant *: Name: Arizona Department of Transportation Firm: Address: 205 S. 17th St. City: Phoenix State: AZ Zip: 85007 Telephone: 602 712 8811 Fax: Email: Consultant: (Discipline) Name: Firm: Address: City: State: Zip: Telephone: Fax: Email: 7 Project Description/Narrative: (Separate sheet is preferred) Co -location of Venzon Wireless antenna equipment on EXISTING 57' Tucson Electric Power utility power pole. Installation of 5'x13' ground equipment cabinet in ADOT ROW adjacent to pole. I hereby certify that I have read and examined this application and know the same to be true and correct. I am the owner of the property or the Owner's authorized representative, and if not the owner, I have obtained the owner's permission to perform stated work. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The approval of this application does not presume to give authority to violate or cancel the provisions of any other federal, state or local law for which this project may be subject to. Notice: It is the applicant/owner's responsibility to ensure all private rules and regulations (such as Covenants, Conditions & Restrictions (CC&R's)) of the subdivision and/or commercial center are adhered to. Contact your Home Owners Association or property management to determine applicable requirements. It is also the applicant's responsibility to coordinate with all outside agencies to secure their acceptance or clearance. Failure to do so may delay issuance of -permits. See attached list of agencies. Applicant's Si '`re Print Name Date Important Note: All submittals received after 4:00 p.m. will be processed the next day Submittals will be reiiected if: • There are missing items on the checklist unless otherwise approved by Planning and Zoning Administrator or Town Engineer. • Re -submittals cannot be accepted without a transmittal and a response to staff comments. 8 1.3 CONDITIONAL USE PERMIT - SUBMITTAL CHECKLIST No application for a Conditional Use Permit will be accepted until the applicant has scheduled and completed a pre -application conference. All applications for a conditional use permit must include the following materials to be accepted for processing: ❑ Fees (Refer to Section 1.5 Fee Schedule of this process guide) ❑ General application ❑ Narrative detailing request (5 Copies) ❑ Site plan or location map, if applicable — size 11" x 17" (5 Copies) ❑ Please note, additional site specific information may be required ❑ All contents of Section 2.0 of this process guide (5 copies) ❑ Public Outreach Report, in accordance with Section 22.15.E (2 copies) ❑ Letter of authorization from the property owner, if applicable (2 copies) ❑ Copy of Deed or Title Report ❑ Signed notification of potential state or federal issues (Section 4.0) ❑ Electronic version of all submitted items in PDF form. Additional copies will be required for the public hearing process. E verfZOnwireless 1 PINNACLE C0NSULTING. IN''C Public Outreach Plan' f Project: AUG 0 2 2018 TUC Ram —TEP Colocation 11167 N. Oracle Road, $'►����wr............ Oro Valley, AZ 85737 ADOT ROW Applicant: Neal Talaske Pinnacle Consulting, Inc. 1426 N. Marvin St., Gilbert (480) 664-9588 x 220 Neal.Talaske@Pinnacleco.net Client: Verizon Wireless 126 W Gemini Dr., Tempe AZ, 85283 Site Name: TUC Ram Ll Table of Contents Section 1.0 Project Description........................................................................................................................1 Section 2.0 Identification of Interested Stakeholders..................................................................................1 Section 3.0 Proposed Neighborhood Meetings.............................................................................................2 Attachments: Photo Simulations Zoning Drawings Notification Area Map 0 A 1.0 Project Description Verizon Wireless is proposing to install a new wireless communications facility at 11167 N. Oracle Road, Oro Valley. The new facility would be located atop an existing Tucson Electric Power utility pole and would not require the installation of a new vertical structure. The required ground equipment would be located in Arizona Department of Transportation -owned Right -of -Way. The facility would be 70' to the top of antennas, which would be concealed in a stealth canister, mitigating visual impacts to the area. The installation of this facility will provide the surrounding area with enhanced, high-speed Verizon Wireless voice and data capacity. Verizon Wireless strives to identify future gaps or lack in coverage and tailors their infrastructure accordingly to stay ahead of the needs of subscribers. When this new site is activated, businesses, homes, and travelers in the area will see an increase in data transfer speeds and connectivity. 2.0 Identification of Interested Stakeholders Pinnacle Consulting, Inc. has identified the primary stakeholders for this proposed development to be the adjacent land owners in the area, which is primarily composed of commercially zoned lots and Right - of -Way. Per Town of Oro Valley code section 22.15.F.4.a.i, all landowners within 600' of the proposed development will be notified of the neighborhood meeting. 3.0 Proposed Neighborhood Meetings Pinnacle Consulting, Inc. will be facilitating two neighborhood meetings on behalf of Verizon Wireless for this proposed project.. The first neighborhood meeting will be held on 6/20/2018 at 6pm at the Fairfield Inn & Suites Conference Room, 10150 N. Oracle Rd, Oro Valley AZ 85737 for the purpose of answering any questions and addressing any concerns attendees may have. The second meeting will be organized and held by the Town of Oro Valley staff and will be held on 7/12/2018 in order to further inform neighboring land owners and gain feedback towards the proposed development. ■ lu I:rm DEPART 126 W GEMINI DR, TEMPE, AZ 85283 ON W GEMINI DR. CONTINUE ONTO S PRIEST DR. TURN RIGHTONTO W ELLIOT RD. USE THE LEFT 2 LANES TO TURN LEFT TO MERGE ONTO 1-10 E TOWARD TUCSON. MERGE ONTO 1-10 E. TAKE EXIT 240 FOR TANGERINE RD. TURN LEFT ONTO W TANGERINE RD. TURN RIGHT ONTO N ORACLE RD. AFTER 1.4 MILES THE SITE WILL BE ON THE RIGHT. VICINITY MAP PROJECT AREA TUC RAM AP N : N/A 11167 N. ORACLE ROAD ORO VALLEY, AZ 85737 PIMA COUNTY SCOPE OF WORK • INSTALL PROPOSED 57'-0" TEP UTIUTY POLE (BY UTILITY) • INSTALL PROPOSED 5k13' ELEVATED PLATFORM WITH S'TALL STEALTH SCREENING • INSTALL (1) PROPOSED POLE EXTENSION SECTOR FRAME (DESIGN BY OTHERS) • INSTALL (1) PROPOSED ANTENNA STEALTH SCREENING (DESIGN BY OTHERS) • INSTALL PROPOSED OUTDOOR CABINET • INSTALL PROPOSED ELECTRICAL SERVICE • INSTALL PROPOSED TELCO SERVICE • INSTALL (6) PROPOSED ANTENNAS • INSTALL (12) PROPOSED REMOTE RADIO HEADS •' INSTALL (2) PROPOSED H-FRAME • INSTALL (1) PROPOSED OVP AT GROUND LEVEL • INSTALL (1) PROPOSED OVP AT ANTENNA LEVEL • INSTALL (2) PROPOSED HYBRID CABLES SHEET INDEX T-1 PROJECT INFORMATION LS-1 TOPOGRAPHIC SURVEY Z-1 SITE PLAN Z-2 ENLARGED SITE PLAN AND ANTENNA PLAN Z-3 ELEVATIONS Z-4 ELEVATIONS CLIENT VERIZON WIRELESS 126 W. GEMINI DR. TEMPE, AZ 85283 CONTACT: RICK MIRANDA PHONE: 1602) 390-9844 PROPERTY OWNER A.D.O.T, 205 S 17TH AVE. PHOENIX, AZ 85007 CONTACT: TIM MAHONEY PHONE: (602) 712-8811 TOWER OWNER TUCSON ELECTRIC POWER 88 E. BROADWAY BLVD. TUCSON, AZ 85701 CONTACT: DANNY MADRIL PHONE: (520) 661-9460 SITE ACQUISITION PINNACLE CONSULTING. INC. 1426 N. MARVIN STREET #101 GILBERT, AZ 85233 CONTACT: MICHELLE LAMOUREUX PHONE: (480) 664-9588 e#. 230 PROJECT DATA ZONING: R.OW. PARCEL #: N/A USE: UNMANNED COMMUNICATIONS NEW LEASE AREA: 220 SO. FT JURISDICTION: ORO VALLEY GOVERNING CODES: 20121BC, 20121FC, 20121MC, 2011 NEC ALL BUILDING CODES LISTED ABOVE SHALL INCLUDE AMENDMENTS BY THE GOVERNING JURISDICTION A&E FIRM NEW SITE LOCATION PINNACLE CONSULTING, INC. 1426 N. MARVIN STREET #101 LATITUDE 32.40857' 32`24' 30.8514" N (NAD83) GILBERT, AZ 85233 LONGITUDE 110.94366` 110' 56' 37.1754" W (NAD83) CONTACT: KYLE FORTIN GROUND ELEVATION 2616.7' (NAVD88) PHONE: (623) 217-4235 1. THIS WIRELESS TELECOMMUNICATIONS FACILITY WILL MEET THE HEALTH AND SAFETY STANDARDS FOR ELECTROMAGNETIC FIELD EMISSIONS AS ESTABLISHED BY THE FEDERAL COMMUNICATIONS COMMISSION OR ANYSUCCESSOR THEREOF, AND ANY OTHER FEDERAL OR STATE AGENCY. 2. THIS WIRELESS TELECOMMUNICATIONS FACILITY WILL MEET THE REGULATIONS OF THE FEDERAL COMMUNICATIONS COMMISSION REGARDING PHYSICAL AND ELECTROMAGNETIC INTERFERENCE, 3. LIGHTING OR SIGNS WILL BE PROVIDED ONLY AS REQUIRED BY FEDERAL OR STATE AGENCIES. 4. DEVELOPMENT AND CONSTRUCTION OF THIS PROJECT WILL COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES. 5. EXISTING PARKING IS NOT AFFECTED BY THIS PROJECT. 6. THIS PROJECT DOES NOT INCLUDE WATER OR SEWER. (RF): DATE: (CONST.): (RE): DATE: DATE: LANDLORD: DATE: PRE -RED FOR verizonv 125 W. GEMINI DR. TEMPE. AZ 85283 PHONE (480) 7774380 FAX (480) 7774391 CONSULTING FIRM PINNACLE _,_rsi�uclon P,olect Management $,le Develnpnx::t 1426 N MARVIN STREET # 101 GILBERT AZ 85233 PROJECT NO: TUC RAM DRAWN BY: CGS CHECKED BY KF REV DATE DESCRIPTION BY A 02/26/18 90%ZONING CGS 0 04/23/18 100%ZONING JMC FINAL FOR ZONING lw ONLY u li "� !.\�fv/w` AUG O 2CC99101.Y BT: TUC RAM 11167 N. ORACLE ROAD ORO VALLEY, AZ 85737 PIMA COUNTY SHEET TITLE PROJECT INFORMATION SHEET NUMBER T-1 I � I A h I NATRUAL GROUNC J' I 4 I APN: 220084660 BOUNDARY DETAIL I I I ( / ZONING: PAD SCALE: 1 " = 30' I o CD aN Z 4O 1 �� \ \ �I VIE a — SEE SURVEY \ DETAIL a o ___---- __________-__, NATRUAL� � II 1 \ 4 (E) 50' BUILDING SET-BACK.LINE GROUND ' ' — — \ = — — — — — — — � — — — — — — — — r \ t0 11—IE) 20' UTILITY 8 GAS EASEMENT ) f _-_ •((E)20' UTILITY EASEMENT (E)DANy - J-- _-_ _END ACFL END ACLF IF — (3.1WEST) FND PK NAIL -- - — — — _ - 1 _ {E}Btd2BED WIRE FENCE 1 W/SHINERLS26923 (0.9' SOUTH) I (E) BACK OF CURB I (E) EDGE OF PAVEMENT ORACLE ROAD 00 (E)100'R/W (E) MONUMENT LINE LEGEND 0 ALUMINUM CAP FLUSH A PKNJASHER 03 ELECTRICAL PULL BOX ® ELECTRIC MANHOLE ED ELECTRIC CABINET FIBER PEDESTAL POWER POLE # LIGHT POST pd GAS VALVE — GAS MARKER WATER VALVE 0 WATER METER BACKFLOW PREVENTER IRRIGATION CONTROL VALVE ft DECIDUOUS TREE SIGN BREAKLINE X 52e WNG SPOT ELEVATION O SCHEDULE 13HEX POSITION OFGEODETIC COORDINATES — — PROPERTY LINE — — PROPERTY LINE (OTHER) — MONUMENT LINE — — — — EASEMENT LINE x x WIRE OR BARBED WIRE FENCE —ONE ONE— OVERHEAD ELECTRIC LINE ucE UGE— U/G ELECTRIC LINE --- - _:' U/G FIBER OPTIC LINE —G—G—G— U/G GAS LINE WATER LINE APN ASSESSORS PARCEL NUMBER CAB CABINET CS CONCRETE SURFACE D/W DRIVEWAY INV INVERT NG NATURAL GRADE PV ASPHALT SL STREET LIGHT RAN RIGHTOFWAY TBC TOP OF CURB TW TOP OF WALL VLT VAULT �lw s --- sF — —� --- \------------------------- BRICK \ / PAVERS \ 10 11 (E) 15' UTILITY —8 EMENT — W s �--� W Vie_ F G SURVEYOR NOTES 1. ALLTITLE INFORMATION IS BASED UPON A COMMITMENT FOR TITLE INSURANCE PREPARED BY FIRST AMERICAN TITLE INSURANCE CO., ORDER NO 21800324 EFFECTIVE DATE: 01232018. 2 SURVEYOR HAS NOT PERFORMEDA SEARCH OF PUBLIC RECORDS TO DETERMINE ANY DEFECT IN TITLE. 3 THE BOUNDARY SHOWN HEREON IS PLOTTED FROM RECORD INFORMATION AND DOES NOT CONSTITUTE A BOUNDARY SURVEY OF THE PROPERTY 4. SURVEYOR DOES NOT GUARANTEE THAT ALL UTILITIES ARE SHOWN OR THEIR LOCATIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND DEVELOPER TO CONTACT BLUE STAKE AND ANY OTHER INVOLVED AGENCIES TO LOCATE ALL UTILITIES PRIOR TO CONSTRUCTION. REMOVAL, RELOCATION AND/ OR REPLACEMENT IS THE RESPONSIBILITY OF THE CONTRACTOR. PROJECT META DATA 1 ELEVATIONS SHOWN HEREON ARE REPRESENTED IN NORTH AMER/CAN VERTICAL DATUM OF 196E (NAV066) ESTABLISHED FROM GPS DERIVED ELLIPSOID HEIGHTS, APPLYING GEOID 12B SEPARATIONS CONSTRAINING TO NGS CORS STATIONS PROVIDED IN THE "ONLINE POSITIONING USER SERVICE' (OPUS) SOLUTION FOR THIS SPECIFIC SITE 2. BEARINGS SHOWED HEREON ARE BASED UPON U S. STATE PLANE NAD83 COORDINATE SYSTEM ARIZONA STATEPLANE COORDINATE ZONE CENTRAL, DETERMINED BY GPS OBSERVATIONS. 3 FIELD WORK FOR THIS PROJECT WAS PERFORMED ON 02/19/2018. LESSOR'S LEGAL DESCRIPTION LOT 4, OF STEAM PUMP VILLAGE PHASE 3, ACCORDING TO THE PLAT OF RECORD IN THE OFFICE OF THE COUNTY RECORDER OF PIMA COUNTY. ARIZONA, RECORDED IN BOOK 64 OF MAPS AND PLATS, PAGE 95 FLOOD ZONE DESIGNATION THE PROPOSED LEASE PREMISES SHOWN HEREON APPEAR TO BE WITHIN FLOOD ZONE "X' AS DELINEATED ON THE FEDERAL EMERGENCY MANAGEMENT AGENCY FIRM MAP NO. 04019C1090L DATED 06/'.62011 (E) DRIVEWAY Ilf 2618 -- f W W W$ W FLOOD ZONE "X' IS DEFINED AS AREAS DETERMINED TO BE OUTSIDE 500-YEAR FLOODPLAIN; DETERMINED TO BE OUTSIDE THE 1%AND 0.2%ANNUAL CHANCE SCHEDULE B EXCEPTIONS FLOODPLAINS OEASEMENTS, RESTRICTIONS, RESERVATIONS, CONDITIONS AND SET -BACK LINES AS SET FORTH ON THE PLAT RECORDED IN BOOK 64 OF MAPS, PAGE 29, BUT DELETING ANY COVENANT, CONDITION OR RESTRICTION INDICATING A PREFERENCE, LIMITATION OR DISCRIMINATION BASED ON RACE, COLOR, RELIGION, SEX, HANDICAP, FAMILIAL STATUS OR NATIONAL ORIGIN TO THE EXTENT SUCH COVENANTS. CONDITIONS OR RESTRICTIONS VIOLATE 42 USC 3604(C). 4O EASEMENTS, RESTRICTIONS, RESERVATIONS, CONDITIONS AND SET -BACK ONES AS SET FORTH ON THE PLAT RECORDED IN BOOK 64 OF MAPS, PAGE 95, BUT DELETING ANY COVENANT, CONDITION OR RESTRICTION INDICATING A PREFERENCE, LIMITATION OR DISCRIMINATION BASED ON RACE, COLOR, RELIGION, SEX, HANDICAP, FAMILIAL STATUS OR NATIONAL ORIGIN TO THE EXTENT SUCH COVENANTS, CONDITIONS OR RESTRICTIONS VIOLATE 42 USC 3604(C), 10' 41 , 10. AN EASEMENT FOR PUBLIC UTILITIES AND ALL MATTERS AS SET FORTH ,NET C THEREIN, RECORDED IN DOCKET 13817, PAGE 3194 OF OFFICIAL RECORDS OR ry 00AN EASEMENT FOR GAS LINES AND ALL MATTERS AS SET FORTH THEREIN, DECLINATION RECORDED IN DOCKET 1383Z PAGE 808 OF OFFICIAL RECORDS. ITEMS 1-2, 5-9 AND 12-13OF THE CLIENT PROVIDED TITLE REPORT DO NOT GRAPHIC SCALE CONTAIN GRAPHICALLY PLOTTABLE EASEMENTS, SETBACKS, RESTRICTIONS 10 0 5 10 20 .. OR OTHER ENCUMBRANCES, AND/OR BLANKET IN NATURE OR DO NOT AFFECT SUBJECT SITE.. THE SURVEYOR CANNOT GUARANTEE THAT NON-PLOTTABLE ENCUMBRANCES DO NOT EXIST THAT MAY AFFECT THE SUBJECT LEASED ( IN FEET ) PREMISES. L inch = 10 ft. \ SURVEY DETAIL \ SCALE: 1"= 70' s'\\ NATURAL \ GROUND \ \ q (E)50' BUILDING SET -BACK LINE (E) BACK OF CURB W W ORACLE ROAD 00(E) 100' RNJ (E) RETAINING U `LESSOR'S PARCEL LINE UGE UGEUG2 !/ /'NATURAL s / GROUND -- �Psi> W W _ VLT nfi sss 3 4 (E)10' UTILITY EASEMENT — - — — — — — — c - . e ao1 (E)WIRE FENCE — 55439M 2 1111' — — — TI \1yl T 81.49— - m I z6,H 2617 A 41 T,A. ''' NATURAL OIYGROUND c Rq�a �92. Rop°eggG� <P 2— CgT'Y WW WF D��iN—W WW WW — verizowl 126 W. GEMINI DR. TEMPE. AZ 85283 PINNACLE CONSUL'rING, INC. Construction - Project Management - Ste Development 1426 N. MARVIN STREET # 101 GILBERT, AZ 85233 FIELD BY: CEF DRAWN BY: CRS CHECKED BY: ABM REVISIONS I LNI. 02/22/18 PRELIMINARY DATE DESCRIPTION RL_F-- CC3NSLJLTINC3 SFTACE . ti R CONSUL'�i.vG CD•� .. q_ NG s E014NA G EXPIRES 03/51/13 REUSE OF DOCUMENT THE IDEAS 8 DESIGN INCORPORATED HEREON, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF RLF CONSULTING, LLC 8 IS NOT TO BE USED FOR ANY OTHER PROJECT WITHOUT WRITTEN AUTHORIZATION OF RILE CONSULTING, LLC PROJECT No. 10008555 SITE NAME: TUC RAM SITE ADDRESS: 11167 N ORACLE ROAD ORO VALLEY, AZ 85737 SHEET TITLE: TOPOGRAPHIC SURVEY N SHEET NO. REVISION: LS-1 / EXISTING 50' WIDE / BUILDING / SETBACK UNE / / / / / / _ EXISTING 20' WIDE UTILITY AND GAS / EASEMENT / EXISTING TREE, TYP. / /FG / G / / EXISTING 20' WIDE / UTIUTY EASEMENT / /G GF° / / / G / / f / \,nJlnw�i'S i CrS� 1-1 / J S` C ��- 3 Z-2 /G PROPOSED VERIZON 9'-0" / C e x 24'-6" LEASE AREA o/f / / G .\ 1p Y G� /4° SITE PLAN / / EXISTING R.O.W. LINE. EXISTING TEN UTILITY POLE, TO BE . REMOVED AND REPLACED / r"o PROPOSED 5T0" TALL TEPUTILITY POLE (BY UTILITY) EXISTING UNDERGROUND FIBER OPTIC UNE, TYP. 44 / EXISTING UNDERGROUND / WATER LINE, TYP. T4° ` O 110, �90Oa 06IPO / --\\ / V- 24'k30"SCALE; 1" = 5' 11 k17" SCALE: 1`= 11' EXISTING OVERHEAD ELECTRICAL LINE, TYP. EXISTING UNDERGROUND ELECTRICAL LINE, TYP. PREPNRED FOR. verizon 128 W. GEMINI DR. TEMPE. AZ B52B0 PHONE (480)7T7- FAX (480) 777-4391 QPINNACLE Consiructgn aro�eci Ma v�- �I ��Ie DevEl":prrv_nt 1426 N MARMN STREET # tot GILBERT, AZ 85233 PROJECT NO: TUC RAM DRAWN BY: CGS CHECKED BY: KF IIIIII'IIIIIIIIIIIII'-IIIIIII' FINAL FOR FOR ZONING ONLY TUC RAM 11167 N. ORACLE ROAD ORO VALLEY, AZ 85737 PIMA COUNTY SH EET TITLE SITE PLAN SHEET NUMBER Z-1 5 1' 3 1 EXISTING UNDERGROUND GAS UNE, TYP. NEW COAXIAL CABLE TABLE SECTOR AZIMUTH LENGTH OTY, SIZE TYPE ALPHA 50° 1100, 2 11/4"0 HYBRIFLEX CABLE BETA 170' GAMMA 290' NOTE: ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE 'IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH RF DEPARTMENT PRIOR TO INSTALLING ANTENNAS. CABLING DETAIL *NOTE: • ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE • IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH RF DEPARTMENT PRIOR TO INSTALUNG ANTENNAS PROPOSED STEALTH SCREENING (DESIGN BY OTHERS) PROPOSED VERIZON STACKED REMOTE RADIO HEAD, (4) PER SECTOR FOR (3) SECTORS PROPOSED POLE EXTENSION SECTOR FRAME W/ (2) ANTENNA PIPE MOUNTS (DESIGN BY OTHERS) ANTENNA PLAN EXISTING TREW-TYP.q- I PROPOSED VERIZON PANEL ANTENNAS (2) PER SECTOR FOR (3) SECTORS (1) PROPOSED VERIZON OVP MOUNTED ON ANTENNA MOUNT PROPOSED 57'-0"TALL TEP UTILITY POLE (BY UTILITY) 24 24'x36"SCALE:1/2"=1'-0'kt ]`SCALE: 1/4'= 1-0' " 12 1 ENLARGED SITE PLAN ' y 9 a N J O w m � EXISTING UNDERGROUND WATER UNE, TYP. � I EXISTING OVERHEAD ELECTRICAL LINE, TYP. o EXISTING UNDERGROUND ELECTRICAL LINE, TYP. EXISTING UNDERGROUND FIBER OPTCI UNE, TYP. EXISTING TEP UTILITY POLE, TO BE —FO REMOVED AND REPLACED � o oW i-a 0 7 PROPOSED 57'-0" TALL TEP UTILITY POLE (BY UTILITY) IN III ZON LEASE AREA 2'-Z' (2) PROPOSED 4" CONDUITS LOCATED BELOW GRADE 11 o—UGE—U[ FUTURE VERIZON CABINET �wE WE-UPe� UGE� (4) PROPOSED. WIDE ACCESS DOORS I FUTURE VERIZON OVP MOUNTED ON H-FRAME (1) PROPOSED VERIZON OVP MOUNTED ON H-FRAME I� PROPOSED VERI ION 200A OUTDOOR RATED INTEGRATE[ LOAD CENTER ON PROPOSED H-FRAME I PROPOSED VERIZON GPS ANTENNA I PROPOSED VERIZON CABINET MOUNTED TO PROPOSED PLATFORM PROPOSED 5'x13' WIDE ELEVATED PLATFORM WITH B' TALL STEALTH SCREENING III (2) PROPOSED 4' WIDE ACCESS DOORS 9 PROPOSED VERIZON TELCO DEMARCATION ON PROPOSED H-FRAME PROPOSED VERIZON METER/DISCONNECT BANK MOUNTED TO PROPOSED H-FRAME I PROPOSED VERIZON 9'-0" x 24'-6" LEASE AREA EXISTING UNDERGROUND 4'-5" 2'-5" ELECTRICAL LINE, TYP. I EXISTING R.O.W. UNE. 3 3 3 3 3 3 3 3 PREPARED FOR'. ■ verizon 126 W, GEMINI DR. TEMPE. AZ BU83 PHONE (480) ]]74360 FAX (480) PINNACLE ­LTING, INC. COrtstrucl.,n pll' iNnw3ement Sne DeveloPn�eM 1426 N. MARVIN STREET # 101 GILBERT. AZ 85233 PROJECT NO' TUC RAM DRAWN BY: CGS CHECKED BY: KF 11111111111111111- I I I I I, III♦IIIIIIII■—III■ III♦IIIIIIII♦—III♦ FINAL FOR ZONING ONLY 3 TUC RAM 3 11167 N. ORACLE ROAD ORO VALLEY, AZ 85737 PIMA COUNTY 3 SHEET TUt ENLARGED SITE PLAN AND ANTENNA PLAN SHEET NUMBER Z-2 24'k38"SCALE: B/B'=7'-0' 11 k17' SCALE Z. 3 I$ TOP OF PROPOSED VERIZON ANTENNAS Y ELEVATION 70'-0" A.G.L *r.fAT9BLiNE4EPAD2DaE�, IR ZQNANTENNAS--- ELEVATION 66'-0" A.G.L 40 TOP OF PROPOSED TEP UTILITY POLE ELEVATION 57'-0" A.G.L J� TOP OF EXIS ING OVERHEAD LINE ELEVATION 51'-0" A.G.L J� TOP OF EXISTING OVERHEAD LINE V ELEVATION 48'-0" A.G.L TOP OF EXISTING OVERHEAD LINE ELEVATION 45'-0" A.G. L STOP OF EXISTING OVERHEAD LINE ELEVATION 42'-0" A. G.L n TOP OF EXISTNG OVERHEAD LINE V ELEVATION 36I-0" A.G.L n TOP OF EXISTING OVERHEAD LINE V ELEVATION 24'-0" A. G.L PROPOSED VERIZON GPS ANTENNA PROPOSED 5'x13' WIDE _ ELEVATED PLATFORM WITH 8' TALL STEALTH SCREENING x PROPOSED VERIZON TELCO DEMARCATION ON i PROPOSED H-FRAME PROPOSED VERIZON METER/DISCONNEC BANK MOUNTED TO PROPOSED H-FRAME EXISTING GRADE NEW SOUTHEAST ELEVATION PROPOSED STEALTH SCREENING (DESIGN BY OTHERS) PROPOSED VERIZON PANEL ANTENNAS (2) PER SECTOR FOR (3) SECTORS PROPOSED POLE EXTENSION SECTOR FRAME W/ (2) ANTENNA PIPE MOUNTS (DESIGN BY OTHERS) PROPOSED VERIZON STACKED REMOTE RADIO HEAD, (4) PER SECTOR FOR (3) SECTORS (1) PROPOSED VERIZON OVP MOUNTED ON ANTENNA MOUNT EXISTING TEP UTILITY POLE, TO BE REMOVED AND REPLACED PROPOSED 57'-0" TALL TEP UTILITY POLE (BY UTILITY) (2) PROPOSED VERIZON HYBRID CABLE(S) ROUTED ALONG INSIDE OF PROPOSED TEP UTILITY POLE. PROPOSED VERIZON CABINET MOUNTED TO PROPOSED PLATFORM PROPOSED VERIZON 200A OUTDOOR RATED INTEGRATED LOAD CENTER ON PROPOSED H-FRAME (1) PROPOSED VERIZON OVP MOUNTED ON H-FRAME FUTURE VERIZON OVP MOUNTED ON H-FRAME (2) PROPOSED 4" CONDUITS LOCATED BELOW GRADE ih TOP OF PROPOSED VERIZON ANTENNAS Y ELEVATION 70'-0" A.G.L ELEVATION 56-0" A.G.L $TOP OF PROPOSED TEP UTILITY POLE ELEVATION 57'-0" A.G.L i^ TOP OF EXISTING OVERHEAD LINE Y ELEVATION 51'-0" A.G.L TOP OF EXISTING OVERHEAD LINE ELEVATION 48'-0" A.G,L TOP OF EXISTING OVERHEAD LINE ELEVATION 45'-0" A. G.L TOP-OF',EXISTING OVERHEAD LINE ELEVATN 42'-0" A. G.L TOP OF EXISTING OVERHEAD LINE ELEVATION 36'-0" A.G. L I$ TOP OF EXISTING OVERHEAD LINE ELEVATION 24'-0" A. G.L EXISTING GRADE PROPOSED STEALTH SCREENING (DESIGN BY OTHERS) PROPOSED VERIZON PANEL ANTENNAS (2) PER SECTOR FOR (3) SECTORS PROPOSED POLE EXTENSION SECTOR FRAME W/ (2) ANTENNA PIPE MOUNTS (DESIGN BY OTHERS) PROPOSED VERIZON STACKED REMOTE RADIO HEAD, (4) PER SECTOR FOR (3) SECTORS (1) PROPOSED VERIZON OVP MOUNTED ON ANTENNA MOUNT PREPARED FOR verizon✓ 126 W. GEMINI OR TEMPE. A2 —83 PHONIE (aefi) n7rafi0 FAX (480) 71713B, CONSULTING FIRM PINNACLE Go, —lqn P,,,I-Management Ste Develop—, 1426 N. MARVIN STREET # 101 GILBERT. AZ 85233 PROJECT NO'. TUC RAM I DRAWN BY CGS I CHECKED BY. KF PROPOSED VERIZON GPS ANTENNA _ PROPOSED VERIZON CABINET MOUNTED TO PROPOSED PLATFORM x PROPOSED VERIZON 200A OUTDOOR — RATED INTEGRATED LOAD CENTER ON PROPOSED H-FRAME t = (1) PROPOSED VERIZON OVP MOUNTED ON H-FRAME FUTURE VERIZON OVP MOUNTED ON H-FRAME - \� (2) PROPOSED 4" CONDUITS LOCATED BELOW GRADE 11M7SCALE'3K 1 NEW NORTHWEST ELEVATION EXISTING TEP UTILITY POLE, TO BE REMOVED AND REPLACED PROPOSED 5T-0" TALL TEP UTILITY POLE (BY UTILITY) (2) PROPOSED VERIZON HYBRID CABLE(S) ROUTED ALONG INSIDE OF PROPOSED TEP UTILITY POLE. PROPOSED 5'x13' WIDE ELEVATED PLATFORM WITH 8' TALL STEALTH SCREENING PROPOSED VERIZON — TELCO DEMARCATION ON PROPOSED H-FRAME PROPOSED VERIZON METER/DISCONNECT BANK MOUNTED TO PROPOSED H-FRAME 2Yk.. SCALE: tlwt]' SCA LE III�III��® —III■ --�IIIII, —III■ FINAL FOR ZONING ONLY TUC RAM 11167 N. ORACLE ROAD ORO VALLEY, AZ 85737 PIMA COUNTY SHEET TITLE ELEVATIONS SHEET NUMBER Z-3 OOIOOPOSED VERIZON ANTENNAS ET'-0" A.G.L QLMI3LLHF QE-ER0R!Q3FG YERIZIMANTENNAS--- ELEVATION 66'-0" A.G.L TOP OF PROPOSED TEP UTILITY POLE ELEVATION 57'-0" A.G.L J TOP OF EXISTING OVERHEAD LINE Y ELEVATION 51'-0" A.G.L I\ TOP OF EXISTING OVERHEAD LINE ELEVATION 48'-0" A.G.L &TOP OF EXISTING OVERHEAD LINE ELEVATION 45'-0" A. G.L n TOP OF EXISTING OVERHEAD LINE J' ELEVATION 42'-0" A. G.L p TOP OF EXTING OVERHEAD LINE Y' ELEVATIOISN 36'-0" A. G.L n TOP OF EXISTING OVERHEAD LINE ELEVATION 24'-0" A. G.L 26'-2" TO BACK OF CURB EXISTING GRADE NEW SOUTHWEST ELEVATION PROPOSED STEALTH SCREENING (DESIGN BY OTHERS) PROPOSED VERIZON PANEL ANTENNAS (2) PER SECTOR FOR (3) SECTORS PROPOSED POLE EXTENSION SECTOR FRAME W/ (2) ANTENNA PIPE MOUNTS (DESIGN BY OTHERS) PROPOSED VERIZON STACKED REMOTE RADIO HEAD, (4) PER SECTOR FOR (3) SECTORS (1) PROPOSED VERIZON OVP MOUNTED ON ANTENNA MOUNT EXISTING TEP UTILITY POLE, TO BE REMOVED AND REPLACED PROPOSED 57'-0" TALL TEP UTILITY POLE (BY UTILITY) x (2) PROPOSED VERIZON HYBRID CABLE(S) ROUTED ALONG INSIDE x OF PROPOSED TEP UTILITY POLE. v..-1� PROPOSED VERIZON CABINET MOUNTED TO PROPOSED PLATFORM PROPOSED 5'x13' WIDE ELEVATED PLATFORM WITH 8'TALL STEALTH SCREENING (2) PROPOSED 4" CONDUITS LOCATED BELOW GRADE ELEVATPROPOSED VERIZON ANTENNAS ION 70'-0" A.G.L CCMFRLWF-Qf-EaOPOSEQYERIZQCLAN.TENNAS _-_ ELEVATION 66'-0" A.G.L TOP OF PROPOSED TEP UTILITY POLE ELEVATION 5T-0" A.G.L f� TOP OF EXISTING OVERHEAD LINE �' ELEVATION 51'-0" A.G.L J� TOP OF EXISTING OVERHEAD LINE ELEVATION 48'-0" A. 6.1- n TOP OF EXISTING OVERHEAD LINE V ELEVATION 45'-0" A.G.L TOP OF EXISTING OVERHEAD LINE ELEVATION 42'-0" A.G. L TOP OF EXISTING OVERHEAD LINE ELEVATION 36'-0" A. G.L \ / �( PROPOSED 5'x13' WIDE ? ELEVATED PLATFORM WITH 8'TALL STEALTH SCREENING EXISTING GRADE 0 24k36"SCALE .. 3;16'32' 1`° 11 1 NEW NORTHEAST ELEVATION 1tk17"SCALE'. 3!' t'�0 PROPOSED STEALTH SCREENING (DESIGN BY OTHERS) PROPOSED VERIZON PANEL ANTENNAS (2) PER SECTOR FOR (3) SECTORS PROPOSED POLE EXTENSION SECTOR FRAME W/ (2) ANTENNA PIPE MOUNTS (DESIGN BY OTHERS) PROPOSED VERIZON STACKED REMOTE RADIO HEAD, (4) PER SECTOR FOR (3) SECTORS (1) PROPOSED VERIZON OVP MOUNTED ON ANTENNA MOUNT of o x EXISTING TEP UTILITY POLE. TO BE REMOVED AND REPLACED PROPOSED 57'-0" TALL TEP UTILITY POLE (BY UTILITY) i(2) PROPOSED VERIZON HYBRID CABLE(S) ROUTED ALONG INSIDE OF PROPOSED TEP UTILITY POLE. x PROPOSED VERIZON GPS ANTENNA PROPOSED VERIZON CABINET MOUNTED TO PROPOSED PLATFORM PROPOSED VERIZON METER/DISCONNECT BANK MOUNTED TO PROPOSED H-FRAME 26'-2" TO BACK OF CURB (2) PROPOSED 4" CONDUITS LOCATED BELOW GRADE 24k36' SCALE: 3/18" = 1'-0" I tkt7"SCALE: 1(16' = 1-0' PREPARED FOR verizon✓ 126 W. GEMINI DR. TEMPE. AZ 85283 PHONE (480) 7774— FAX (480) 7774391 PINNACLE -„r�st,uclr�n Prolxt Maregement Site Oevelopmen; 1426 N. MARVIN STREET # 101 GILBERT, AZ 85233 PROJECT NO: TUC RAM DRAWNBY. CGS CHECKED BY KF REV DATE DESCRIPTION BY A 02 25 18 90--::ZONING CGS 0 O4i23: 18 100 _ ZONING JMC FINAL FOR ZONING ONLY TUC RAM 11167 N. ORACLE ROAD ORO VALLEY. AZ 85737 PIMA COUNTY \ SHEET TITLE ELEVATIONS SHEET NUMBER Z-4 2